← Back
Over six families without stores
48-16 47 STREET
QUEENS · BIN 4432187
💬 Discuss this project
1924Year Built
5Stories
C1Building Class
R5Zoning
230,000 sfGross Floor Area
390Units
LL97 CoveredRent Stabilized103 Open Violations 101 unresolved · 2 paperwork only ▸FDNY Report ↗
Over six families without stores · Owner of record: COSMOPOLITAN ASSOCIATES III, LLC · 99,837 sf lot · 2.3 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 11 docs
Cellar1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COSMOPOLITAN ASSOCIATES507/08/2026
CANIDO BASONAS CONST SVC203/22/2026
COSMOPOLITAN ASSOCIATES III203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK ENGINEERING ASSOC., P.C.110/01/2025
SRS ARCHITECT, PC205/30/2023
360 ENGINEERING P.C.111/16/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P C203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPIRE SCAFFOLDING & HOISTGeneral Contractor407/08/2026
CANIDO BASONAS CONST SVCGeneral Contractor207/08/2026
GMAK PLMBG AND HEATNG LLCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851110/01/2025
SRS ARCHITECT, PC2434205/30/2023
Building Lifecycle
All (86)Filed (4)Permit Issued (6)Signed Off (3)Violation (60)Inspection (2)Objection (4)Special Inspection (7)
04/24/2026
Signed off — Alteration
FILING FOR CROSS CONNECTING TWO BOILERS' DOMESTIC HOT WATER COILS FOR BUILDINGS 48-45 46th STREET AND 48-55 46th STREET.
Q01290233-I1
03/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/05/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/11/2026
Permit issued — Plumbing
Q01290233-I1-PL
10/16/2025
Permit issued — Plumbing
Q01290233-I1-PL
10/01/2025
Filed — Alteration
FILING FOR CROSS CONNECTING TWO BOILERS' DOMESTIC HOT WATER COILS FOR BUILDINGS 48-45 46th STREET AND 48-55 46th STREET.
Q01290233-I1
09/19/2025
Special inspection requirement — Tenant Protection Plan Compliance
LOUIS ARENA
04/21/2024
Violation issued (HPD, closed)
B
06/30/2023
Signed off — Alteration
EXTERIOR FACADE RESTORATION AS PER PLAN. NO CHANGE IN USE EGRESS OR OCCUPANCY. SIDEWALK SHED IF REQUIRED, TO BE FILED SEPARATELY.
Q00594646-I1
06/22/2023
Special inspection requirement — Masonry
Silvia Schlaen
06/22/2023
Special inspection requirement — Final
Silvia Schlaen
06/22/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Silvia Schlaen
06/09/2023
Objection resolved — Addressed
06/09/2023
Objection resolved — Addressed
06/08/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Silvia Schlaen
06/01/2023
Objection raised — Scope
06/01/2023
Objection raised — Inspections
05/30/2023
Filed — Alteration
EXTERIOR FACADE RESTORATION AS PER PLAN. NO CHANGE IN USE EGRESS OR OCCUPANCY. SIDEWALK SHED IF REQUIRED, TO BE FILED SEPARATELY.
Q00594646-P1
04/11/2023
Signed off — Alteration
Q00628180-I1
02/28/2023
Special inspection requirement — Masonry
Silvia Schlaen
02/28/2023
Special inspection requirement — Final
Silvia Schlaen
10/13/2022
Permit issued — General Construction
Q00594646-I1-GC
05/13/2022
Violation issued (HPD, closed)
A
05/13/2022
Violation issued (HPD, closed)
A
05/13/2022
Violation issued (HPD, closed)
A
05/13/2022
Violation issued (HPD, closed)
C
05/13/2022
Violation issued (HPD, closed)
A
04/29/2022
Permit issued — Sidewalk Shed
Q00628180-I1-SH
03/24/2022
Violation issued (ECB, closed)
Construction
03/24/2022
Violation issued (ECB, closed)
Construction
11/16/2021
Filed — Alteration
Q00628180-I1
11/16/2021
Permit issued — Sidewalk Shed
Q00628180-I1-SH
11/01/2021
Permit issued — General Construction
Q00594646-I1-GC
10/08/2021
Filed — Alteration
EXTERIOR FACADE RESTORATION AS PER PLAN. NO CHANGE IN USE EGRESS OR OCCUPANCY. SIDEWALK SHED IF REQUIRED, TO BE FILED SEPARATELY.
Q00594646-I1
06/11/2021
Violation issued (HPD, closed)
A
06/11/2021
Violation issued (HPD, closed)
C
06/11/2021
Violation issued (HPD, closed)
A
06/11/2021
Violation issued (HPD, closed)
B
06/11/2021
Violation issued (HPD, closed)
B
06/11/2021
Violation issued (HPD, closed)
C
06/11/2021
Violation issued (HPD, closed)
C
06/11/2021
Violation issued (HPD, closed)
A
06/11/2021
Violation issued (HPD, closed)
B
06/11/2021
Violation issued (HPD, closed)
B
04/16/2021
Violation issued (HPD, closed)
A
05/31/2019
Violation issued (HPD, closed)
B
05/31/2019
Violation issued (HPD, closed)
C
05/31/2019
Violation issued (HPD, closed)
B
05/31/2019
Violation issued (HPD, closed)
B
05/31/2019
Violation issued (HPD, closed)
A
05/31/2019
Violation issued (HPD, closed)
A
05/31/2019
Violation issued (HPD, closed)
B
09/05/2018
Violation issued (HPD, closed)
B
09/05/2018
Violation issued (HPD, closed)
B
09/05/2018
Violation issued (HPD, closed)
B
09/05/2018
Violation issued (HPD, closed)
C
08/10/2018
Violation issued (HPD, open)
B
08/10/2018
Violation issued (HPD, closed)
B
08/10/2018
Violation issued (HPD, closed)
B
08/10/2018
Violation issued (HPD, open)
B
Latest 60 of 86 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offGMAK PLMBG AND HEATNG LLC02/11/2026
DOB NOWPlumbingSigned-offGMAK PLMBG AND HEATNG LLC10/16/2025
DOB NOWGeneral ConstructionSigned-offCANIDO BASONAS CONST SVC10/13/2022
DOB NOWSidewalk ShedSigned-offSPIRE SCAFFOLDING & HOIST04/29/2022
DOB NOWSidewalk ShedSigned-offSPIRE SCAFFOLDING & HOIST11/16/2021
DOB NOWGeneral ConstructionSigned-offCANIDO BASONAS CONST SVC11/01/2021
1 project · most recent 03/24/2022
FiledStatusContractorScope
03/24/2022CompleteNASH ELECTRIC SERVICES IN—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/05/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/05/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
09/19/2025Tenant Protection Plan ComplianceLOUIS ARENAspecial
06/22/2023MasonrySilvia Schlaenspecial
06/22/2023FinalSilvia Schlaenprogress
06/22/2023Structural Stability – Alterations of existing buildingsSilvia Schlaenspecial
06/08/2023Structural Stability – Alterations of existing buildingsSilvia Schlaenspecial
02/28/2023MasonrySilvia Schlaenspecial
02/28/2023FinalSilvia Schlaenprogress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026Q00628180-I1Request digital key ↗
08/24/2026Q00594646-I1Request digital key ↗
08/18/2026Q01290233-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026Q00594646-I1Open ↗
08/13/2026Q01290233-I1Open ↗
08/13/2026Q00594646-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/27/2026Q01290233-I1Open ↗
08/25/2026Q00594646-P1Open ↗
08/24/2026Q00594646-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q00594646-P1Open ↗
08/24/2026Q00594646-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026Q00594646-I1Open ↗
08/13/2026Q00594646-P1Open ↗