| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/19/2024 | Complete | A ELECTRICAL MAIN SVC INC | 3 meters, 3 new_meters |
| 03/11/2024 | Complete | A ELECTRICAL MAIN SVC INC | General Wiring |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 03/21/2023 | $875K | — | Private party → Private party | $388/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| MEHDI GHAZI, P.E., P.C. | 6 | 01/08/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| ALPHA HOME DESIGN LLC | 12 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| PRIMROSE SERVICE INC | General Contractor | 1 | 07/08/2026 |
| WASOFF PLBG & UTILITY CO | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| MEHDI GHAZI, P.E. P.C. | 7129 | 6 | 01/08/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | WASOFF PLBG & UTILITY CO | 05/04/2023 |
| DOB NOW | General Construction | Signed-off | PRIMROSE SERVICE INC | 05/03/2023 |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/16/2024 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 04/12/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 09/01/2023 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 09/01/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 09/01/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/01/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/30/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/09/2024 | Energy Code Compliance Inspections | MEHDI GHAZI | progress |
| 01/09/2024 | Fire-Resistant Penetrations and Joints | MEHDI GHAZI | special |
| 01/09/2024 | Fire-Resistant Penetrations and Joints | MEHDI GHAZI | special |
| 01/09/2024 | Interior lighting power | MEHDI GHAZI | energy_progress |
| 01/09/2024 | Fenestration air leakage | MEHDI GHAZI | energy_progress |
| 01/09/2024 | Fenestration areas | MEHDI GHAZI | energy_progress |
| 01/09/2024 | Fenestration and door U-factor and product ratings | MEHDI GHAZI | energy_progress |
| 01/09/2024 | Energy Code Compliance Inspections | MEHDI GHAZI | progress |
| 01/09/2024 | Concrete - Cast-In-Place | MEHDI GHAZI | special |
| 01/08/2024 | Energy Code Compliance Inspections | MEHDI GHAZI | progress |
| 01/08/2024 | Fire-Resistant Penetrations and Joints | MEHDI GHAZI | special |
| 08/25/2023 | Fire-Resistant Penetrations and Joints | MEHDI GHAZI | special |
| 08/25/2023 | Energy Code Compliance Inspections | MEHDI GHAZI | progress |
| 08/25/2023 | Concrete - Cast-In-Place | MEHDI GHAZI | special |
| 08/25/2023 | Interior lighting power | MEHDI GHAZI | energy_progress |
| 08/25/2023 | Fenestration air leakage | MEHDI GHAZI | energy_progress |
| 08/25/2023 | Fenestration areas | MEHDI GHAZI | energy_progress |
| 08/25/2023 | Fenestration and door U-factor and product ratings | MEHDI GHAZI | energy_progress |
| 08/21/2023 | Energy Code Compliance Inspections | MEHDI GHAZI | progress |
| 08/21/2023 | Fire-Resistant Penetrations and Joints | MEHDI GHAZI | special |