← Back
One story retail building
59-02 MAIN STREET
QUEENS · BIN 4439944
💬 Discuss this project
1941Year Built
1Stories
K1Building Class
R5BZoning
7,000 sfGross Floor Area
7Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: ANSWER ENTERPRISES LLC · 10,755 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG & ASSOCIATES LLC208/15/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZAQ CONSTRUCTION INCGeneral Contractor203/21/2026
R & T ELECTRICAL CORPElectrical103/22/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG & ASSOCIATES LLC7330208/15/2024
Building Lifecycle
All (14)Filed (2)Permit Issued (2)Signed Off (2)Violation (3)Inspection (5)
04/06/2026
Violation issued (FDNY_NOV, closed)
01/30/2025
Signed off — Alteration
INSTALL PLUMBING FIXTURES AS SHOWN ON PLAN @ CELLAR & 1ST FLOOR. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01094876-I1
01/14/2025
Signed off — Alteration
RENOVATION AS SHOWN ON PLAN @ CELLAR & 1ST FLOOR STORE AREA. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01094833-I1
12/20/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/12/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/25/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/25/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/21/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/26/2024
Permit issued — Plumbing
Q01094876-I1-PL
08/21/2024
Permit issued — Mechanical Systems
Q01094833-I1-GC-CX
08/15/2024
Filed — Alteration
INSTALL PLUMBING FIXTURES AS SHOWN ON PLAN @ CELLAR & 1ST FLOOR. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01094876-I1
08/15/2024
Filed — Alteration
RENOVATION AS SHOWN ON PLAN @ CELLAR & 1ST FLOOR STORE AREA. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01094833-I1
03/25/2021
Violation issued (FDNY_NOV, closed)
06/02/1992
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP08/26/2024
DOB NOWMechanical SystemsSigned-offZAQ CONSTRUCTION INC08/21/2024
BISPLISSUEDMAINLAND PLG. & HTG07/15/1994
BISFPISSUEDMETFLOW FIRE CONTROL LLC05/20/1994
BISPLISSUEDMAINLAND PLG. & HTNG.05/16/1994
BISOTISSUEDCITY KING DECORATION INC05/09/1994
1 project · most recent 09/05/2024
General Wiring
FiledStatusContractorScope
09/05/2024CompleteR & T ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
12/20/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/12/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/25/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/25/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/21/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01094833-I1Request digital key ↗
08/21/2026Q01094876-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01094876-I1Open ↗
08/13/2026Q01094833-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01094876-I1Open ↗
08/13/2026Q01094833-I1Open ↗