← Back
Condo, residential unit in 1-3 story building
Powells Cove View Condominium
3-03 127 STREET · BIN 4449810
💬 Discuss this project
1980Year Built
2Stories
R3Building Class
R3-2Zoning
18,032 sfGross Floor Area
8Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Condo, residential unit in 1-3 story building · Owner of record: POWELLS COVE VIEW CONDO · 30,019 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 12p · 1 filing · 20 docs
Basement2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
POWELLS COVE VIEW CONDO103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LCW ENGINEERING, P.C.610/30/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARK DESIGN & BUILD INCGeneral Contractor107/08/2026
PAUL TRAKTMAN LIC PLBR INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LCW ENGINEERING, PC1103310/30/2024
Building Lifecycle
All (32)Filed (6)Permit Issued (2)Signed Off (2)Violation (9)Inspection (7)Special Inspection (6)
11/25/2025
Violation issued (HPD, closed)
I
12/27/2024
Signed off — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-I1
12/24/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/04/2024
Violation issued (HPD, closed)
I
10/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
luis wong
10/31/2024
Special inspection requirement — Energy Code Compliance Inspections
luis wong
10/31/2024
Special inspection requirement — Lighting in dwelling units
luis wong
10/30/2024
Filed — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-P4
10/08/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/24/2024
Filed — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-P3
09/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
luis wong
09/19/2024
Special inspection requirement — Energy Code Compliance Inspections
luis wong
09/19/2024
Special inspection requirement — Lighting in dwelling units
luis wong
08/20/2024
Violation issued (ECB, closed)
Construction
03/22/2024
Signed off — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-S1
03/21/2024
Filed — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-P2
03/12/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/07/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/16/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/08/2024
Filed — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-P1
02/07/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/07/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/02/2024
Permit issued — Plumbing
Q00962118-S1-PL
12/05/2023
Permit issued — General Construction
Q00962118-I1-GC
11/29/2023
Violation issued (HPD, closed)
I
11/28/2023
Filed — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-I1
11/28/2023
Filed — Alteration
Interior renovation of an existing apartment with new partition walls, flooring and kitchen cabinets. No changes to the use, egress or occupancy.
Q00962118-S1
11/18/2022
Violation issued (HPD, closed)
I
04/13/2021
Violation issued (HPD, closed)
C
04/12/2021
Violation issued (HPD, closed)
I
04/11/2021
Violation issued (HPD, closed)
C
09/16/2017
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPAUL TRAKTMAN LIC PLBR IN01/02/2024
DOB NOWGeneral ConstructionSigned-offARK DESIGN & BUILD INC12/05/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
12/24/2024Pass-Final General Construction Non-Directive 14PassView ↗
10/08/2024Fail-Final General Construction Non-Directive 14FailView ↗
03/12/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/07/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/16/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/07/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/07/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/31/2024Fire-Resistant Penetrations and Jointsluis wongspecial
10/31/2024Energy Code Compliance Inspectionsluis wongprogress
10/31/2024Lighting in dwelling unitsluis wongenergy_progress
09/19/2024Fire-Resistant Penetrations and Jointsluis wongspecial
09/19/2024Energy Code Compliance Inspectionsluis wongprogress
09/19/2024Lighting in dwelling unitsluis wongenergy_progress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026Q00962118-P4Request digital key ↗
08/21/2026Q00962118-P3Request digital key ↗
08/21/2026Q00962118-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026Q00962118-P1Open ↗
08/13/2026Q00962118-P3Open ↗
08/13/2026Q00962118-P4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/26/2026Q00962118-P3Open ↗
09/26/2026Q00962118-P3Open ↗
08/24/2026Q00962118-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/26/2026Q00962118-P3Open ↗
08/24/2026Q00962118-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/13/2026Q00962118-I1Open ↗
08/13/2026Q00962118-P4Open ↗
08/13/2026Q00962118-P3Open ↗
Showing 3 of 6 on file for this type