← Back
Bungalow colony - cooperatively owned land
202-30 ROCKAWAY POINT BLVD
QUEENS · BIN 4465474
💬 Discuss this project
1938Year Built
1Stories
A8Building Class
R4Zoning
460,000 sfGross Floor Area
539Units
LL97 Covered11 Open Violations 2 unresolved · 9 paperwork only ▸FDNY Report ↗
Bungalow colony - cooperatively owned land · Owner of record: BREEZY POINT COOPERATIVE, INC · 3,589,344 sf lot · 0.13 FAR built · Flood zone AE
Locations of Work
Architecture
Floor 21p · 1 filing · 13 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BREEZY POINT COOPERATIVE, INC.603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BUNGALOW DESIGN & ENGINEERING PC301/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUNGALOW DESIGN & ENGINEE4105201/27/2026
Building Lifecycle
All (31)Filed (3)Objection (7)Special Inspection (21)
03/19/2026
Objection resolved — Addressed
03/19/2026
Objection resolved — Addressed
03/19/2026
Objection resolved — Addressed
02/20/2026
Objection raised — Scope
02/19/2026
Objection raised — Structural
02/19/2026
Objection raised — Admin
02/19/2026
Objection raised — Zoning
01/27/2026
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH Q01345817-I1,INCLUDING WATER, SANITARY, AND GAS
Q01345817-S1
01/27/2026
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH Q01345817-I1,INCLUDING WATER, SANITARY, AND GAS
Q01345817-S2
01/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Deidre Duffy
01/27/2026
Special inspection requirement — Maintenance information
Deidre Duffy
01/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Deidre Duffy
01/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Deidre Duffy
01/27/2026
Special inspection requirement — Permanent certificate
Deidre Duffy
01/26/2026
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH Q01345817-I1,INCLUDING WATER, SANITARY, AND GAS
Q01345817-I1
01/26/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Deidre Duffy
01/26/2026
Special inspection requirement — Air barrier - visual inspection
Deidre Duffy
01/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Deidre Duffy
01/26/2026
Special inspection requirement — Concrete - Cast-In-Place
Deidre Duffy
01/26/2026
Special inspection requirement — Insulation placement and R values
Deidre Duffy
01/26/2026
Special inspection requirement — Fenestration air leakage
Deidre Duffy
01/26/2026
Special inspection requirement — Maintenance information
Deidre Duffy
01/26/2026
Special inspection requirement — Fenestration areas
Deidre Duffy
01/26/2026
Special inspection requirement — Permanent certificate
Deidre Duffy
01/26/2026
Special inspection requirement — Interior lighting power
Deidre Duffy
01/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Deidre Duffy
01/26/2026
Special inspection requirement — Energy Code Compliance Inspections
Deidre Duffy
01/26/2026
Special inspection requirement — Fire-Resistance Rated Construction
Deidre Duffy
01/26/2026
Special inspection requirement — Structural Wood Frame
Deidre Duffy
01/13/2026
Special inspection requirement — Footing and Foundation
Deidre Duffy
01/13/2026
Special inspection requirement — Final
Deidre Duffy
Nothing on file for this building.
1 project · most recent 01/27/2026
Gas Water/Sanitary
FiledStatusContractorScope
01/27/2026——Gas, Water/Sanitary
1 project · most recent 01/27/2026
Wood
FiledStatusContractorScope
01/27/2026——Wood
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
01/27/2026HVAC-R and service water piping design and insulationDeidre Duffyenergy_progress
01/27/2026Maintenance informationDeidre Duffyenergy_progress
01/27/2026Fire-Resistant Penetrations and JointsDeidre Duffyspecial
01/27/2026Energy Code Compliance InspectionsDeidre Duffyprogress
01/27/2026Permanent certificateDeidre Duffyenergy_progress
01/26/2026Fenestration and door U-factor and product ratingsDeidre Duffyenergy_progress
01/26/2026Air barrier - visual inspectionDeidre Duffyenergy_progress
01/26/2026HVAC-R and service water piping design and insulationDeidre Duffyenergy_progress
01/26/2026Concrete - Cast-In-PlaceDeidre Duffyspecial
01/26/2026Insulation placement and R valuesDeidre Duffyenergy_progress
01/26/2026Fenestration air leakageDeidre Duffyenergy_progress
01/26/2026Maintenance informationDeidre Duffyenergy_progress
01/26/2026Fenestration areasDeidre Duffyenergy_progress
01/26/2026Permanent certificateDeidre Duffyenergy_progress
01/26/2026Interior lighting powerDeidre Duffyenergy_progress
01/26/2026Fire-Resistant Penetrations and JointsDeidre Duffyspecial
01/26/2026Energy Code Compliance InspectionsDeidre Duffyprogress
01/26/2026Fire-Resistance Rated ConstructionDeidre Duffyprogress
01/26/2026Structural Wood FrameDeidre Duffyprogress
01/13/2026Footing and FoundationDeidre Duffyprogress
01/13/2026FinalDeidre Duffyprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01345817-S2Request digital key ↗
08/17/2026Q01345817-S1Request digital key ↗
08/17/2026Q01345817-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/29/2026Q01345817-S1Open ↗
08/29/2026Q01345817-S1Open ↗
08/29/2026Q01345817-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q01345817-I1Open ↗
08/13/2026Q01345817-S1Open ↗
08/13/2026Q01345817-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026Q01345817-S1Open ↗
08/23/2026Q01345817-I1Open ↗