← Back
Bungalow colony - cooperatively owned land
217-02 BREEZY POINT BLVD
QUEENS · BIN 4465938
💬 Discuss this project
1938Year Built
1Stories
A8Building Class
R4Zoning
1,600,000 sfGross Floor Area
1,906Units
LL97 Covered60 Open Violations 2 unresolved · 58 paperwork only ▸FDNY Report ↗
Bungalow colony - cooperatively owned land · Owner of record: BREEZY POINT COOPERATIVE, INC · 12,253,428 sf lot · 0.13 FAR built · Flood zone AE
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 10/21/2020
Gas Water/Sanitary
FiledStatusContractorScope
10/21/2020——Gas, Water/Sanitary
1 job · most recent 10/21/2020
Fence
FiledStatusContractorScope
10/21/2020——Fence
Building Lifecycle
All (18)Filed (3)Permit Issued (3)Signed Off (1)Violation (1)Objection (6)Special Inspection (4)
11/22/2021
Signed off — Alteration
Replacement of deck in relation to violation 35441610Z. No change to use egress or occupancy.
Q00463050-I1
08/23/2021
Permit issued — Structural
Q00463050-I1-GC-CX
08/10/2021
Permit issued — Structural
Q00463050-I1-GC-CX
05/28/2021
Permit issued — General Construction
Q00463050-I1-GC-CX
02/19/2021
Objection raised — Zoning
02/19/2021
Objection resolved — Addressed
02/02/2021
Filed — Alteration
Replacement of deck in relation to violation 35441610Z. No change to use egress or occupancy.
Q00463050-I1
01/29/2021
Special inspection requirement — Concrete - Cast-In-Place
Gary Lenhart
01/29/2021
Special inspection requirement — Final
Gary Lenhart
01/15/2021
Violation issued (ECB, closed)
Construction
10/27/2020
Objection raised — Inspections
10/27/2020
Objection raised — Fire_Protection
10/23/2020
Objection raised — Inspections
10/23/2020
Objection resolved — Resolved
10/21/2020
Filed — Alteration
All plumbing fixtures including gas, and water related to NB application.
Q00356306-I1
10/21/2020
Filed — Alteration
Construction fence on grade.
Q00356318-I1
06/15/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Gary Lenhart
06/15/2020
Special inspection requirement — Fire-Resistance Rated Construction
Gary Lenhart
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BREEZY POINT COOPERATIVE, INC.1103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CMC DESIGN ARCHITECT, P.C.302/02/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AC BUILDING CONSULTANTS603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HUNT MCNAMEE INCGeneral Contractor603/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CMC DESIGN ARCHITECT, P.C2984202/02/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offHUNT MCNAMEE INC08/23/2021
DOB NOWStructuralSigned-offHUNT MCNAMEE INC08/10/2021
DOB NOWGeneral ConstructionSigned-offHUNT MCNAMEE INC05/28/2021
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
01/29/2021Concrete - Cast-In-PlaceGary Lenhartspecial
01/29/2021FinalGary Lenhartprogress
06/15/2020Fire-Resistant Penetrations and JointsGary Lenhartspecial
06/15/2020Fire-Resistance Rated ConstructionGary Lenhartprogress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Structural1
08/15/2026Q00463050-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/15/2026Q00463050-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/14/2026Q00356318-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/27/2026Q00356306-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
12/14/2020440599988Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISFLOOD ZONE DESIGN CERTIFICATION1
07/20/2020440599988Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00463050-I1Open ↗
08/13/2026Q00356318-I1Open ↗
08/13/2026Q00356306-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q00463050-I1Open ↗
08/26/2026Q00356306-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00463050-I1Open ↗
08/26/2026Q00356306-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
09/04/2020440599988Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
07/20/2020440599988Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/20/2020440599988Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/20/2020440599988Open ↗
▸Approvals, Objections & Sign-offs2
▸BISNYS DEC TIDAL WETLANDS APPROVAL1
09/04/2020440599988Open ↗
▸BISNYS DEC COASTAL EROSION HAZARD APPROVAL1
09/04/2020440599988Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
07/20/2020440599988Open ↗
▸Other Documents4
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
09/04/2020440599988Open ↗
09/04/2020440599988Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
07/20/2020440599988Open ↗
▸BISPLOT DIAGRAM1
09/04/2020440599988Open ↗