Single or multiple dwelling with stores or offices
150-11 NORTHERN BOULEVARD
QUEENS · BIN 4532172
💬 Discuss this project
2005Year Built
5Stories
S9Building Class
R6AZoning
7,850 sfGross Floor Area
6Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: SUNG & SUNG EQUITIES (NYC) LLC · 1,600 sf lot · 4.91 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 42p · 1 filing · 9 docs
Floor 3
Floor 21p · 1 filing · 9 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SUNG & SUNG EQUITIES (NYC) LLC203/22/2026
NORTHERN 8983203/21/2026
NORTHERN 8883403/21/2026
PRINCE 8881503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KENNY LEE ARCHITECT310/02/2025
KORMAN DESIGN & BUILD110/16/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KENNY LEE ARCHITECT103/21/2026
KORMAN DESIGN & BUILD603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KORMAN DESIGN & BUILDGeneral Contractor403/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KORMAN DESIGN & BUILD8792310/02/2025
KORMAN DESIGN & BUILD2055110/16/2019
Building Lifecycle
All (33)Filed (4)Permit Issued (2)Signed Off (2)Violation (7)Inspection (1)Objection (4)Special Inspection (13)
02/11/2026
Signed off — Alteration
Q01292409-I1
02/06/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/30/2025
Permit issued — General Construction
Q01292409-I1-GC
10/02/2025
Filed — Alteration
Q01292409-S1
10/02/2025
Filed — Alteration
Q01292409-S2
10/01/2025
Filed — Alteration
Q01292409-I1
09/30/2025
Special inspection requirement — Heating Systems
KENNY LEE
09/30/2025
Special inspection requirement — Tenant Protection Plan Compliance
KENNY LEE
09/29/2025
Special inspection requirement — Tenant Protection Plan Compliance
KENNY LEE
09/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
KENNY LEE
09/29/2025
Special inspection requirement — Energy Code Compliance Inspections
KENNY LEE
09/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
KENNY LEE
09/29/2025
Special inspection requirement — Metering
KENNY LEE
09/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
KENNY LEE
09/26/2025
Special inspection requirement — Tenant Protection Plan Compliance
KENNY LEE
09/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
KENNY LEE
07/22/2022
Violation issued (FDNY_NOV, closed)
03/09/2022
Violation issued (HPD, closed)
A
04/19/2021
Violation issued (HPD, closed)
A
11/15/2019
Signed off — Alteration
REPLACEMENT OF CONDENSING UNIT .
Q00245752-I1
11/13/2019
Permit issued — Mechanical Systems
Q00245752-I1-MS
11/04/2019
Violation issued (HPD, closed)
I
10/25/2019
Objection raised — Other
10/25/2019
Objection resolved — Addressed
10/25/2019
Objection raised — Admin
10/25/2019
Objection resolved — Addressed
10/16/2019
Filed — Alteration
REPLACEMENT OF CONDENSING UNIT .
Q00245752-I1
10/14/2019
Special inspection requirement — Mechanical Systems
DAVID UH
10/14/2019
Special inspection requirement — Final
DAVID UH
10/14/2019
Special inspection requirement — Energy Code Compliance Inspections
DAVID UH
05/14/2018
Violation issued (ECB, closed)
Construction
01/24/2012
Violation issued (FDNY_NOV, closed)
07/28/2011
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKORMAN DESIGN & BUILD12/30/2025
DOB NOWMechanical SystemsSigned-offKORMAN DESIGN & BUILD11/13/2019
BISMHISSUEDNORTHERN07/03/2007
BISPLISSUEDACCURATE MECHANICAL INC06/14/2007
BIS—ISSUEDUNITECH DESIGN INC06/07/2007
BISOTISSUEDKORMAN DESIGN & BUILD06/05/2007
BISSPISSUEDHEADS UP FIRE SPRINKLER09/16/2005
BISPLISSUEDORBIT PLBG & HTG INC08/16/2005
BIS—ISSUED168 CONSTRUCTION INC07/01/2005
BIS—ISSUED168 CONSTRUCTION INC04/01/2005
BISMHISSUED168 CONSTRUCTION INC01/10/2005
BIS—ISSUED168 CONSTRUCTION INC07/28/2004
BIS—ISSUEDGENERATION BUILDING CO., LIC03/16/2004
1 project · most recent 10/31/2025
General Wiring
FiledStatusContractorScope
10/31/2025CompleteY.S ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
02/06/2026Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
09/30/2025Heating SystemsKENNY LEEspecial
09/30/2025Tenant Protection Plan ComplianceKENNY LEEspecial
09/29/2025Tenant Protection Plan ComplianceKENNY LEEspecial
09/29/2025Fire-Resistant Penetrations and JointsKENNY LEEspecial
09/29/2025Energy Code Compliance InspectionsKENNY LEEprogress
09/29/2025HVAC-R and service water piping design and insulationKENNY LEEenergy_progress
09/29/2025MeteringKENNY LEEenergy_progress
09/29/2025HVAC-R and service water heating system controlsKENNY LEEenergy_progress
09/26/2025Tenant Protection Plan ComplianceKENNY LEEspecial
09/24/2025Fire-Resistant Penetrations and JointsKENNY LEEspecial
10/14/2019Mechanical SystemsDAVID UHspecial
10/14/2019FinalDAVID UHprogress
10/14/2019Energy Code Compliance InspectionsDAVID UHprogress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch2
08/18/2026Q01292409-S2Request digital key ↗
08/18/2026Q01292409-S1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/14/2026Q00245752-I1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature4
08/23/2026Q00245752-I1Open ↗
08/23/2026Q00245752-I1Open ↗
08/22/2026Q01292409-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/27/2026Q01292409-S2Open ↗
08/27/2026Q01292409-I1Open ↗
08/23/2026Q00245752-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/18/2026Q01292409-S1Open ↗
08/18/2026Q01292409-S2Open ↗
08/13/2026Q00245752-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWTenant Protection Plan1
08/13/2026Q00245752-I1Open ↗