← Back
Unlicensed parking lot
444 BEACH 67 STREET
QUEENS · BIN 4595335
💬 Discuss this project
0Year Built
—Stories
G7Building Class
R6Zoning
0 sfGross Floor Area
0Units
7 Open Violations ▸FDNY Report ↗
Unlicensed parking lot · Owner of record: GOD'S BATTALION OF PRAYER PROPERTIES · 4,000 sf lot · 0 FAR built · Flood zone AE
Locations of Work
StructuralMechanicalFire Protection
Roof2p · 1 filing · 20 docs
Bulkhead2p · 1 filing · 20 docs
Floor 93p · 1 filing · 20 docs
Floor 83p · 1 filing · 20 docs
Floor 72p · 1 filing · 20 docs
Floor 62p · 1 filing · 20 docs
Floor 52p · 1 filing · 20 docs
Floor 42p · 1 filing · 20 docs
Floor 32p · 1 filing · 20 docs
Floor 23p · 1 filing · 20 docs
Floor 1
1 job · most recent 07/19/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/19/2025——Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg ×4
Heating
Neotherm LLARS NEOTHERM LC NTH 1200 193 tons · Boiler ×2
Ventilation
Greenheck Greenheck G-098-VG 120 CFM · Exhaust Fan ×8
Greenheck G-097-VG 120 CFM · Exhaust Fan ×5
Lg LG ARNU36B8A4 40,600 BTU · Vrf Indoor ×2
LG ARNU183SKA4 21,500 BTU · Vrf Indoor ×1
LG ARNU18B8A4 19,100 BTU · Vrf Indoor ×1
LG ARNU18BHA4 21,500 BTU · Vrf Indoor ×1
LG ARNU24BHA4 27,300 BTU · Vrf Indoor ×1
LG ARNU24SKA4 25,600 BTU · Vrf Indoor ×1
LG ARNU42B8A4 42,200 BTU · Vrf Indoor ×1
__Junk__ AX-72-190-0617-A50 209 CFM · Exhaust Fan ×2
SS1-12-432-D 120 CFM · Exhaust Fan ×1
1 job · most recent 07/19/2025
Sprinkler System
FiledStatusContractorScope
07/19/2025——Sprinkler System
1 job · most recent 07/19/2025
Steel Concrete Masonry
FiledStatusContractorScope
07/19/2025——Steel, Concrete, Masonry
Building Lifecycle
All (107)Filed (8)Violation (7)Objection (62)Special Inspection (30)
06/23/2026
Objection resolved — Resolved
03/26/2026
Special inspection requirement — Sprayed fire-resistant materials
03/26/2026
Special inspection requirement — Lighting in dwelling units
03/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/26/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/26/2026
Special inspection requirement — Maintenance information
03/26/2026
Special inspection requirement — Air barrier - visual inspection
03/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/26/2026
Special inspection requirement — Fenestration areas
03/26/2026
Special inspection requirement — Metering
03/26/2026
Special inspection requirement — Insulation placement and R values
03/26/2026
Special inspection requirement — Fireplaces
03/26/2026
Special inspection requirement — Permanent certificate
03/26/2026
Special inspection requirement — Air barrier continuity plan testing
03/26/2026
Special inspection requirement — Interior lighting power
03/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/26/2026
Special inspection requirement — Protection of exposed foundation insulation
03/26/2026
Special inspection requirement — Lighting controls
03/26/2026
Special inspection requirement — Duct leakage testing, insulation and design
03/26/2026
Special inspection requirement — Electrical motors and elevators
03/26/2026
Special inspection requirement — Vestibules
03/26/2026
Special inspection requirement — Exterior lighting power
03/26/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
03/26/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
03/26/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
03/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/26/2026
Special inspection requirement — Masonry
03/26/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
03/26/2026
Special inspection requirement — Subgrade Inspections
03/26/2026
Special inspection requirement — Underpinning
03/26/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
02/09/2026
Objection raised — Other
02/02/2026
Objection resolved — Resolved
12/23/2025
Objection resolved — Resolved
11/06/2025
Objection resolved — Resolved
11/06/2025
Objection resolved — Resolved
11/06/2025
Objection resolved — Resolved
09/08/2025
Objection resolved — Addressed
09/08/2025
Objection resolved — Addressed
09/08/2025
Objection resolved — Addressed
08/05/2025
Objection raised — Other
07/19/2025
Filed — New Building
Mechanical application filed in conjunction with an NB
Q00761543-Z1
05/09/2025
Objection resolved — Resolved
05/09/2025
Objection resolved — Resolved
05/09/2025
Objection resolved — Resolved
05/09/2025
Objection resolved — Addressed
05/09/2025
Objection resolved — Addressed
05/09/2025
Objection resolved — Resolved
05/09/2025
Objection resolved — Resolved
05/09/2025
Objection resolved — Addressed
05/09/2025
Objection resolved — Resolved
07/18/2023
Objection raised — Other
06/26/2023
Objection resolved — Addressed
05/30/2023
Objection resolved — Addressed
05/12/2023
Objection resolved — Addressed
04/21/2023
Objection resolved — Addressed
04/03/2023
Objection raised — Admin
04/03/2023
Objection raised — Scope
04/03/2023
Objection raised — Inspections
04/03/2023
Objection raised — Admin
Latest 60 of 107 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRISA BUILDERS2203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MARTIN H. KAPELL207/19/2025
WEXLER ASSOCIATES303/28/2023
SKYLINE ENGINEERING, LLC303/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.1603/21/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
03/26/2026Sprayed fire-resistant materials—special
03/26/2026Lighting in dwelling units—energy_progress
03/26/2026HVAC-R and service water heating system controls—energy_progress
03/26/2026Fenestration and door U-factor and product ratings—energy_progress
03/26/2026Maintenance information—energy_progress
03/26/2026Air barrier - visual inspection—energy_progress
03/26/2026HVAC-R and service water piping design and insulation—energy_progress
03/26/2026Fenestration areas—energy_progress
03/26/2026Metering—energy_progress
03/26/2026Insulation placement and R values—energy_progress
03/26/2026Fireplaces—energy_progress
03/26/2026Permanent certificate—energy_progress
03/26/2026Air barrier continuity plan testing—energy_progress
03/26/2026Interior lighting power—energy_progress
03/26/2026HVAC-R and service water heating equipment—energy_progress
03/26/2026Protection of exposed foundation insulation—energy_progress
03/26/2026Lighting controls—energy_progress
03/26/2026Duct leakage testing, insulation and design—energy_progress
03/26/2026Electrical motors and elevators—energy_progress
03/26/2026Vestibules—energy_progress
03/26/2026Exterior lighting power—energy_progress
03/26/2026Alternative Materials - OTCR Buildings Bulletin Number—special
03/26/2026Excavations - Sheeting, Shoring, and Bracing—special
03/26/2026Exterior Insulation and Finish Systems (EIFS)—special
03/26/2026Fire-Resistant Penetrations and Joints—special
Latest 25 of 51.
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/25/2026Q00761543-Z1Request digital key ↗
08/15/2026Q00761543-I1Request digital key ↗
08/15/2026Q00761543-S1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
11/12/2025440824226Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/12/2025440824226Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/12/2025440824226Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q00761543-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q00761543-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/25/2026Q00761543-I1Open ↗
08/25/2026Q00761543-S1Open ↗
08/25/2026Q00761543-S2Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/12/2025440824226Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/12/2025440824226Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026Q00761543-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/15/2026Q00761543-S1Open ↗
▸Approvals, Objections & Sign-offs8
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter8
08/25/2026Q00761543-Z1Open ↗
08/15/2026Q00761543-I1Open ↗
08/15/2026Q00761543-S1Open ↗
Showing 3 of 8 on file for this type
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
11/12/2025440824226Open ↗
▸Other Documents2
▸DOB NOWSite Survey: Initial1
08/15/2026Q00761543-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q00761543-I1Open ↗