← Back
Court house
80-25 126 STREET
QUEENS · BIN 4620879
💬 Discuss this project
1957Year Built
8Stories
Z1Building Class
C4-4Zoning
596,475 sfGross Floor Area
1Units
LL97 Covered2 Open Violations 0 unresolved · 2 paperwork only ▸
Court house · Owner of record: NYC DEPARTMENT OF TRANSPORTATION · 295,860 sf lot · 2.02 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivilGeneral
Floor 61p · 1 filing · 5 docs
Floor 51p · 1 filing · 5 docs
Floor 41p · 1 filing · 5 docs
Floor 3
Floor 2114p · 2 filings · 20 docs
Floor 1115p · 1 filing · 20 docs
Cellar113p · 1 filing · 20 docs
1 job · most recent 05/02/2024
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/02/2024Permit IssuedHUNTER ROBERTS CONSTRUCTIAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg ARNU243SKA4 25,600 BTU · Vrf Indoor ×6
ARUM241BTE5 233,100 BTU · Vrf Outdoor ×3
ARDE-212-58-30L-15A 89,400 BTU · Vrf Outdoor ×2
ARNU183SKA4 19,100 BTU · Vrf Indoor ×2
ARNU363SVA4 24,200 BTU · Vrf Indoor ×2
ARUM121BTE5 135,000 BTU · Vrf Outdoor ×1
ARUM216BTE5 135,000 BTU · Vrf Outdoor ×1
LSN363HLV3 37,500 BTU · Fan Coil Indoor ×1
LSU363HLV3 36,000 BTU · Condensing Unit ×1
Islandaire EZ42092231S46AA 12,000 BTU · Ptac ×4
EZ2612B2C1N41AA 12,000 BTU · Ptac ×1
Heating
Trane MUH0581MG-PRO 400 CFM · Electric Heater ×7
RIBTW2401B-BC 400 CFM · Electric Heater ×1
Lg ARNH963K2A4 107,500 BTU · Vrf Outdoor ×2
ARNH423K2A4 107,500 BTU · Vrf Indoor ×1
ARNH963K2A4, 107,500 BTU · Vrf Indoor ×1
Ventilation
Greenheck 240AW24A11DD 4,000 CFM · Exhaust Fan ×3
100SQNLEV100SQN17DLVF 150 CFM ×1
120ACRU120R17D0R80VF 420 CFM · Exhaust Fan ×1
150ACRUH2150RH17DVF2 6,725 CFM · Exhaust Fan ×1
90SQNHEV90SQN17DEC 150 CFM · Exhaust Fan ×1
1 job · most recent 05/02/2024
Sprinkler System
FiledStatusContractorScope
05/02/2024Signed-offVANGUARD FIRE SUPP., LLCSprinkler System
1 job · most recent 05/02/2024
Storm Water/Sanitary
FiledStatusContractorScope
05/02/2024Signed-offCARDOZA PLUMBING CORPStorm, Water/Sanitary
2 jobs · most recent 02/24/2025
FiledStatusContractorScope
02/24/2025Permit IssuedHELLMAN ELECTRIC LLC1 meters
02/12/2025CompleteTOP SHELF ELECTRIC CORP—
1 job · most recent 05/02/2024
Steel Concrete Masonry
FiledStatusContractorScope
05/02/2024Permit IssuedHUNTER ROBERTS CONSTRUCTISteel, Concrete, Masonry
Building Lifecycle
All (79)Filed (7)Permit Issued (7)Signed Off (4)Violation (1)Inspection (4)Objection (26)Special Inspection (30)
06/10/2025
Signed off — Alteration
General construction and structural alterations on the 1st thru 6th floors for proposed replacement in-kind of steel brackets supporting existing screen wall. No proposed exterior work; no proposed change to building, use, egress, or occupancy.
Q01155234-I1
06/02/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/30/2025
Signed off — Alteration
Installation of suspended scaffold for facade work or inspection.
Q01189534-I1
05/14/2025
Signed off — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Q01181098-I1
03/06/2025
Permit issued — Suspended Scaffold
Q01189534-I1-SC
03/05/2025
Filed — Alteration
Installation of suspended scaffold for facade work or inspection.
Q01189534-I1
03/04/2025
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Leo Lee
03/04/2025
Special inspection requirement — Post-installed Anchors
Leo Lee
02/21/2025
Permit issued — General Construction
Q01155234-I1-GC-CX
02/19/2025
Permit issued — Sidewalk Shed
Q01181098-I1-SH
02/18/2025
Filed — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Q01181098-I1
02/05/2025
Filed — Alteration
General construction and structural alterations on the 1st thru 6th floors for proposed replacement in-kind of steel brackets supporting existing screen wall. No proposed exterior work; no proposed change to building, use, egress, or occupancy.
Q01155234-I1
01/27/2025
Special inspection requirement — Structural Steel - High Strength Bolting
GEORGE GHEBRYAL
01/27/2025
Special inspection requirement — Structural Steel - Details
GEORGE GHEBRYAL
12/12/2024
Special inspection requirement — Final
GEORGE GHEBRYAL
10/09/2024
Permit issued — Construction Fence
Q01107947-I1-FN
09/10/2024
Filed — Alteration
Q01107947-I1
08/13/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/02/2024
Filed — New Building
Structural alterations related to construction of new 9-story parking garage with cellar and 2-story community facility with cellar; related work as per plans.
Q00495324-A4
05/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Vestibules
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Exterior lighting power
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Air barrier continuity plan testing
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Interior lighting power
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Lighting controls
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Fenestration areas
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Air barrier - visual inspection
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Insulation placement and R values
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Air barrier — testing
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Protection of exposed foundation insulation
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Fenestration air leakage
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Sprayed fire-resistant materials
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Masonry
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Concrete - Cast-In-Place
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
05/02/2024
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
04/29/2024
Special inspection requirement — Insulation placement and R values
GEORGE GHEBRYAL
04/29/2024
Special inspection requirement — Concrete - Cast-In-Place
GEORGE GHEBRYAL
04/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/29/2024
Special inspection requirement — Masonry
GEORGE GHEBRYAL
04/29/2024
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
04/11/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/26/2024
Signed off — New Building
Structural alterations related to construction of new 9-story parking garage with cellar and 2-story community facility with cellar; related work as per plans.
Q00495324-S1
01/09/2024
Permit issued — General Construction
Q00495324-I1-GC
01/25/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/28/2022
Permit issued — General Construction
Q00495324-I1-GC
01/12/2022
Permit issued — General Construction
Q00495324-I1-GC
10/05/2021
Objection raised — Admin
10/05/2021
Objection resolved — Addressed
10/01/2021
Filed — New Building
Structural alterations related to construction of new 9-story parking garage with cellar and 2-story community facility with cellar; related work as per plans.
Q00495324-S1
05/14/2021
Objection raised — Zoning
05/14/2021
Objection resolved — Addressed
05/10/2021
Objection raised — Energy
05/10/2021
Objection resolved — Addressed
05/10/2021
Objection raised — Energy
05/10/2021
Objection resolved — Addressed
05/10/2021
Objection raised — Energy
Latest 60 of 79 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SKYLINE SCAFFOLDING GROUP307/08/2026
NYC DEPARTMENT OF DESIGN AND CONSTR1303/22/2026
TULLY CONSTRUCTION103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KN3 ENGINEERING LLC103/05/2025
RIGID STRUCTURAL DESIGN, LLC102/18/2025
PLAN B ENGINEERING102/05/2025
TAREK M. ZEID, PE, PLLC109/10/2024
URBAHN ARCHITECTS205/02/2024
JOHN BARRY110/01/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARCHETYPE CONSULTANTS803/21/2026
Rigid Structural Design, LLC203/21/2026
AE DESIGN SOLUTION203/21/2026
JMV ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HUNTER ROBERTS CONSTRUCTIONGeneral Contractor803/21/2026
LEON D. DEMATTEIS CONSTGeneral Contractor107/08/2026
SKYLINE SCAFFOLDING GROUPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEO Y LEE ASSOCIATES2481103/05/2025
TECTONIC ENGINEERING CONS106402/05/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldSigned-offSKYTRAC ACCESS GROUP LLC03/06/2025
DOB NOWGeneral ConstructionSigned-offHUNTER ROBERTS CONSTRUCTION02/21/2025
DOB NOWSidewalk ShedSigned-offSKYLINE SCAFFOLDING GROUP02/19/2025
DOB NOWConstruction FencePermit IssuedLEON D. DEMATTEIS CONST10/09/2024
DOB NOWGeneral ConstructionPermit IssuedHUNTER ROBERTS CONSTRUCTION01/09/2024
DOB NOWGeneral ConstructionPermit IssuedHUNTER ROBERTS CONSTRUCTION12/28/2022
DOB NOWGeneral ConstructionPermit IssuedHUNTER ROBERTS CONSTRUCTION01/12/2022
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/02/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/13/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/11/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/25/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
03/04/2025Alternative Materials - OTCR Buildings Bulletin NumberLeo Leespecial
03/04/2025Post-installed AnchorsLeo Leespecial
01/27/2025Structural Steel - High Strength BoltingGEORGE GHEBRYALspecial
01/27/2025Structural Steel - DetailsGEORGE GHEBRYALspecial
12/12/2024FinalGEORGE GHEBRYALprogress
05/02/2024Fire-Resistance Rated ConstructionGEORGE GHEBRYALprogress
05/02/2024VestibulesGEORGE GHEBRYALenergy_progress
05/02/2024Exterior lighting powerGEORGE GHEBRYALenergy_progress
05/02/2024Fenestration and door U-factor and product ratingsGEORGE GHEBRYALenergy_progress
05/02/2024Air barrier continuity plan testingGEORGE GHEBRYALenergy_progress
05/02/2024Interior lighting powerGEORGE GHEBRYALenergy_progress
05/02/2024Lighting controlsGEORGE GHEBRYALenergy_progress
05/02/2024Fenestration areasGEORGE GHEBRYALenergy_progress
05/02/2024Air barrier - visual inspectionGEORGE GHEBRYALenergy_progress
05/02/2024Insulation placement and R valuesGEORGE GHEBRYALenergy_progress
05/02/2024Air barrier — testing GEORGE GHEBRYALenergy_progress
05/02/2024Protection of exposed foundation insulationGEORGE GHEBRYALenergy_progress
05/02/2024Fenestration air leakageGEORGE GHEBRYALenergy_progress
05/02/2024Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
05/02/2024Sprayed fire-resistant materialsGEORGE GHEBRYALspecial
05/02/2024MasonryGEORGE GHEBRYALspecial
05/02/2024Concrete - Cast-In-PlaceGEORGE GHEBRYALspecial
05/02/2024Wall Panels, Curtain Walls, and VeneersGEORGE GHEBRYALspecial
05/02/2024Post-installed AnchorsGEORGE GHEBRYALspecial
05/02/2024Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
Latest 25 of 45.
▾Documents — 141 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01107947-I1Request digital key ↗
08/21/2026Q01155234-I1Request digital key ↗
08/20/2026Q01181098-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications132
▸DOB NOWProgress Inspector Seal & Signature85
08/30/2026Q00495324-P5Open ↗
08/30/2026Q00495324-P5Open ↗
08/30/2026Q00495324-P5Open ↗
Showing 3 of 85 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature43
09/23/2026Q00495324-S4Open ↗
09/01/2026Q00495324-P9Open ↗
08/31/2026Q01189534-I1Open ↗
Showing 3 of 43 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026Q01155234-I1Open ↗
08/13/2026Q01107947-I1Open ↗
08/13/2026Q01181098-I1Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs3
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter3
08/13/2026Q01107947-I1Open ↗
08/13/2026Q01155234-I1Open ↗
08/13/2026Q01181098-I1Open ↗
▸Other Documents2
▸DOB NOWCalculations1
08/13/2026Q01189534-I1Open ↗
▸DOB NOWManufacturer's Specifications1