← Back
Bungalow colony - cooperatively owned land
217-02 BREEZY POINT BLVD
QUEENS · BIN 4623264
💬 Discuss this project
1938Year Built
1Stories
A8Building Class
R4Zoning
1,600,000 sfGross Floor Area
1,906Units
LL97 Covered60 Open Violations 2 unresolved · 58 paperwork only ▸FDNY Report ↗
Bungalow colony - cooperatively owned land · Owner of record: BREEZY POINT COOPERATIVE, INC · 12,253,428 sf lot · 0.13 FAR built · Flood zone AE
Locations of Work
PlumbingFire Protection
Roof2p · 1 filing · 4 docs
Floor 21p · 1 filing · 4 docs
Floor 13p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BREEZY POINT COOPERATIVE, INC.2307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CMC DESIGN ARCHITECT, P.C.307/13/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AC BUILDING CONSULTANTS603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MALBRO CONST SERVICES INCGeneral Contractor903/21/2026
LIQUID PLBG & HTNG SCS INPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CMC DESIGN ARCHITECT, P.C2984207/13/2023
Building Lifecycle
All (25)Filed (3)Permit Issued (5)Violation (1)Inspection (6)Objection (10)
10/20/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/13/2023
Filed — Alteration
New plumbing work related to NB application 421146334.
Q00354032-P1
06/27/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/21/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/13/2023
Permit issued — Plumbing
Q00354032-I1-PL
06/07/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/23/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/23/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/14/2022
Permit issued — Plumbing
Q00354032-I1-PL
04/22/2022
Permit issued — Construction Fence
Q00352493-I1-FN
04/15/2021
Permit issued — Construction Fence
Q00352493-I1-FN
03/25/2021
Permit issued — Construction Fence
Q00352493-I1-FN
12/09/2020
Objection raised — Inspections
12/09/2020
Objection resolved — Addressed
12/09/2020
Objection raised — Fire_Protection
12/09/2020
Objection resolved — Addressed
12/09/2020
Objection raised — Other
12/09/2020
Objection resolved — Addressed
12/09/2020
Objection raised — Other
12/09/2020
Objection resolved — Addressed
12/08/2020
Objection raised — Inspections
12/08/2020
Objection resolved — Addressed
12/04/2020
Filed — Alteration
Construction fence associated with NB 421146334.
Q00352493-I1
12/04/2020
Filed — Alteration
New plumbing work related to NB application 421146334.
Q00354032-I1
11/14/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedLIQUID PLBG & HTNG SCS IN06/13/2023
DOB NOWPlumbingPermit IssuedLIQUID PLBG & HTNG SCS IN05/14/2022
DOB NOWConstruction FencePermit IssuedMALBRO CONST SERVICES INC04/22/2022
DOB NOWConstruction FencePermit IssuedMALBRO CONST SERVICES INC04/15/2021
DOB NOWConstruction FencePermit IssuedMALBRO CONST SERVICES INC03/25/2021
BIS—ISSUEDMALBRO CONST SERVICES INC04/26/2023
BIS—ISSUEDMALBRO CONST SERVICES INC08/15/2022
BIS—ISSUEDMALBRO CONST SERVICES INC04/25/2022
BIS—ISSUEDMALBRO CONST SERVICES INC04/25/2022
BIS—ISSUEDMALBRO CONST SERVICES INC04/15/2021
BIS—ISSUEDMALBRO CONST SERVICES INC03/31/2021
1 job · most recent 07/13/2023
Gas Plumbing-Sprinkler Water/Sanitary
FiledStatusContractorScope
07/13/2023Permit IssuedLIQUID PLBG & HTNG SCS INGas, Plumbing-Sprinkler, Water/Sanitary
1 job · most recent 06/22/2022
General Wiring
FiledStatusContractorScope
06/22/2022Permit IssuedPAPPAS & FODERA ELECT'LGeneral Wiring
1 job · most recent 12/04/2020
Fence
FiledStatusContractorScope
12/04/2020Permit IssuedMALBRO CONST SERVICES INCFence
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
10/20/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/27/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/07/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/23/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/23/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Documents — 73 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
08/24/2026Q00354032-P1Request digital key ↗
08/14/2026Q00354032-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/14/2026Q00352493-I1Request digital key ↗
▸Applications & Permits7
▸BISWORK PERMIT APPLICATION3
05/24/2021421146334Open ↗
05/24/2021421146334Open ↗
04/15/2021421146334Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION3
07/19/2023421146334Open ↗
09/24/2020421146334Open ↗
09/15/2020421146334Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
07/11/2023421146334Open ↗
▸Zoning, Tax Lot & Property Records5
▸BISZONING DIAGRAM2
02/09/2021421146334Open ↗
02/09/2021421146334Open ↗
▸BISVERIFY TAX LOT1
07/18/2023421146334Open ↗
▸BISFLOOD ZONE COMPLIANCE1
07/18/2023421146334Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
07/18/2023421146334Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00352493-I1Open ↗
08/24/2026Q00354032-P1Open ↗
08/24/2026Q00354032-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
05/24/2021421146334Open ↗
▸Trade Schedules & Equipment3
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
07/18/2023421146334Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
07/18/2023421146334Open ↗
▸BISSPRINKLER SYSTEMS1
07/18/2023421146334Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
05/22/2020421146334Open ↗
▸Energy Compliance11
▸BISAIR SEALING AND INSULATION - VISUAL1
07/18/2023421146334Open ↗
▸BISINTERIOR LIGHTING POWER1
07/18/2023421146334Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
07/18/2023421146334Open ↗
▸BISFENESTRATION AREAS1
07/18/2023421146334Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
05/22/2020421146334Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
07/18/2023421146334Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
07/18/2023421146334Open ↗
▸BIS* HVAC INSULATION AND SEALING1
07/18/2023421146334Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
07/18/2023421146334Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/24/2021421146334Open ↗
▸BISFENESTRATION AIR LEAKAGE1
07/18/2023421146334Open ↗
▸Inspections & Test Reports14
▸BISSUBGRADE INSP / SOILS-SITE PREP2
07/18/2023421146334Open ↗
07/18/2023421146334Open ↗
▸BISFRAME (2008)/STRUCTURAL WOOD FRAME (2014) INSPECTION1
07/18/2023421146334Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
07/18/2023421146334Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
02/08/2021421146334Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
07/18/2023421146334Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
07/18/2023421146334Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
07/18/2023421146334Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/08/2021421146334Open ↗
▸BISSOIL REPORT1
02/08/2021421146334Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
05/24/2021421146334Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
02/08/2021421146334Open ↗
▸BISMECHANICAL SYSTEMS1
07/18/2023421146334Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
05/24/2021421146334Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE2
09/15/2020421146334Open ↗
05/22/2020421146334Open ↗
▸BISNYS DEC TIDAL WETLANDS APPROVAL1
02/08/2021421146334Open ↗
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION5
07/31/2023421146334Open ↗
04/07/2021421146334Open ↗
02/09/2021421146334Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM3
05/24/2021421146334Open ↗
05/24/2021421146334Open ↗
05/19/2020421146334Open ↗
▸BISEFILING COVER SHEET1
05/19/2020421146334Open ↗
▸Other Documents13
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION4
10/16/2020421146334Open ↗
10/16/2020421146334Open ↗
10/16/2020421146334Open ↗
Showing 3 of 4 on file for this type
▸BISSHUTOFF DAMPERS1
07/18/2023421146334Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
02/09/2021421146334Open ↗
▸BISLOWEST FLOOR ELEVATION1
07/18/2023421146334Open ↗
▸BISMAINTENANCE INFORMATION1
07/18/2023421146334Open ↗
▸BISPERMANENT CERTIFICATE1
07/18/2023421146334Open ↗
▸BISFIREPLACES1
07/18/2023421146334Open ↗
▸BISON-SITE PRIVATE SEWAGE DISPOSAL SYSTEMS INSTALLATION1
07/18/2023421146334Open ↗
▸BISPLOT DIAGRAM1
05/22/2020421146334Open ↗
▸BISWOOD - PREFABRICATED I-JOISTS1
07/18/2023421146334Open ↗