| Firm | Filings | Most Recent |
|---|---|---|
| PIROOZ ENGINEERING, P.C. | 6 | 05/17/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| A & S CONTRACTORS OF NY I | General Contractor | 4 | 07/08/2026 |
| SUPERIOR PLUMBING & HEATING | Plumbing | 2 | 07/08/2026 |
| WATER WORKS PIPING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| PIROOZ ENGINEERING P.C | 7177 | 4 | 05/17/2026 |
| TRIANGLE INSPECTION & TES | 7495 | 2 | 05/17/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | SUPERIOR PLUMBING & HEATING | 05/06/2026 |
| DOB NOW | Plumbing | Signed-off | SUPERIOR PIPING&MECH CORP | 03/05/2025 |
| DOB NOW | Plumbing | Signed-off | SUPERIOR PLUMBING & HEATI | 08/14/2024 |
| DOB NOW | Construction Fence | Signed-off | A S CONTRACTORS OF NY I | 04/05/2024 |
| DOB NOW | Curb Cut | Signed-off | A S CONTRACTORS OF NY I | 04/05/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/16/2026 | — | — | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Heating A.O. Smith 1738107588745 SERIES 300/301 40,000 BTU · Water Heater ×6 Peerless GSX14036-ARUF37 70,000 BTU · Boiler ×6 Ventilation Panasonic FV-05VQ5 50 CFM · Exhaust Fan ×15 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/17/2026 | — | — | 28 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/17/2026 | Signed-off | SUPERIOR PLUMBING & HEATI | Gas, Plumbing-Sprinkler, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/09/2024 | Complete | TRINCITY ELECTRIC, INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/16/2026 | — | — | Concrete, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/30/2023 | Signed-off | A & S CONTRACTORS OF NY I | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/16/2026 | — | — | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/23/2026 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 05/12/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/29/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/26/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/26/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/26/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 03/23/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/20/2025 | Pass-Final House Connection | Pass | View ↗ |
| 03/14/2025 | Fail-Final House Connection | Fail | View ↗ |
| 03/11/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 08/23/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 08/23/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/23/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/23/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/08/2026 | Fire-Resistant Penetrations and Joints | PIROOZ SOLTANIZADEH | special |
| 06/08/2026 | Sprinkler Systems | PIROOZ SOLTANIZADEH | special |
| 06/08/2026 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | Rajasekhar Sakhamuri | special |
| 06/08/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | PIROOZ SOLTANIZADEH | special |
| 06/08/2026 | Energy Code Compliance Inspections | PIROOZ SOLTANIZADEH | progress |
| 05/14/2026 | Fire-Resistant Penetrations and Joints | PIROOZ SOLTANIZADEH | special |
| 05/14/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | PIROOZ SOLTANIZADEH | special |
| 05/14/2026 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | Rajasekhar Sakhamuri | special |
| 05/14/2026 | Sprinkler Systems | PIROOZ SOLTANIZADEH | special |
| 05/14/2026 | Energy Code Compliance Inspections | PIROOZ SOLTANIZADEH | progress |
| 05/12/2026 | HVAC-R and service water piping design and insulation | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Interior lighting power | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Metering | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Maintenance information | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | HVAC-R and service water heating equipment | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Fenestration areas | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Air barrier — testing | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | HVAC-R and service water heating system controls | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Fenestration air leakage | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Permanent certificate | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Subgrade Inspections | PIROOZ SOLTANIZADEH | special |
| 05/12/2026 | Ventilation and air distribution system | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Electric vehicle service equipment requirements | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Fenestration and door U-factor and product ratings | PIROOZ SOLTANIZADEH | energy_progress |
| 05/12/2026 | Masonry | PIROOZ SOLTANIZADEH | special |