← Back
QUEENS
145-64 230 STREET
QUEENS · BIN 4625284
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
Architecture
Roof1p · 1 filing · 9 docs
Cellar2p · 1 filing · 9 docs
Nothing on file for this building.
Building Lifecycle
All (31)Filed (2)Permit Issued (3)Objection (9)Special Inspection (17)
09/24/2026
Permit issued — Construction Fence
Q01010051-I1-FN
07/29/2026
Objection raised — Accessibility
07/29/2026
Objection resolved — Open
07/29/2026
Objection raised — Other
07/29/2026
Objection raised — Mechanical
07/29/2026
Objection raised — Zoning
07/29/2026
Objection raised — Admin
07/29/2026
Objection raised — Zoning
06/29/2026
Filed — New Building
Q01420407-I1
06/25/2026
Permit issued — Full Demolition
Q01010039-I1-FD
06/23/2026
Special inspection requirement — Concrete - Cast-In-Place
06/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/23/2026
Special inspection requirement — Subgrade Inspections
06/23/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/23/2026
Special inspection requirement — Energy Code Compliance Inspections
06/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/23/2026
Special inspection requirement — Air barrier — testing
06/23/2026
Special inspection requirement — Insulation placement and R values
06/23/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/23/2026
Special inspection requirement — Electric vehicle service equipment requirements
06/23/2026
Special inspection requirement — Air barrier - visual inspection
06/23/2026
Special inspection requirement — Fenestration areas
06/23/2026
Special inspection requirement — Fenestration air leakage
06/23/2026
Special inspection requirement — Interior lighting power
06/23/2026
Special inspection requirement — Maintenance information
06/23/2026
Special inspection requirement — Permanent certificate
06/23/2026
Special inspection requirement — Metering
05/20/2025
Permit issued — Construction Fence
Q01010051-I1-FN
04/05/2024
Objection resolved — Addressed
03/07/2024
Objection raised — Admin
02/26/2024
Filed — Full Demolition
PROPOSED FULL DEMOLITION OF EXISTING 1 STORY FRAMING BUILDING WITH CELLAR AT #145-64 230 STREET QUEENS, NY 11413.
Q01010039-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PRIME REALTY106/27/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAYSIDE ENGINEERING PC206/29/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YAFE MEOD CORPGeneral Contractor209/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010102/26/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedGEOFFREY A. LAGAS & ASSOC09/24/2026
DOB NOWFull DemolitionSigned-offYAFE MEOD CORP06/25/2026
DOB NOWConstruction FencePermit IssuedPRECISION HOME DEV INC05/20/2025
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
06/23/2026Concrete - Cast-In-Place—special
06/23/2026Fire-Resistant Penetrations and Joints—special
06/23/2026Subgrade Inspections—special
06/23/2026Subsurface Investigations (Borings/Test Pits)—special
06/23/2026Energy Code Compliance Inspections—progress
06/23/2026Fire-Resistance Rated Construction—progress
06/23/2026Air barrier — testing —energy_progress
06/23/2026Insulation placement and R values—energy_progress
06/23/2026Fenestration and door U-factor and product ratings—energy_progress
06/23/2026Electric vehicle service equipment requirements—energy_progress
06/23/2026Air barrier - visual inspection—energy_progress
06/23/2026Fenestration areas—energy_progress
06/23/2026Fenestration air leakage—energy_progress
06/23/2026Interior lighting power—energy_progress
06/23/2026Maintenance information—energy_progress
06/23/2026Permanent certificate—energy_progress
06/23/2026Metering—energy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026Q01010039-I1Request digital key ↗
08/15/2026Q01420407-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q01420407-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q01420407-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/15/2026Q01420407-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/23/2026Q01010039-I1Open ↗
08/16/2026Q01420407-I1Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWWater Cut-Off1
08/23/2026Q01010039-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/23/2026Q01010039-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01420407-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/23/2026Q01010039-I1Open ↗
▸DOB NOWRodent Control1
08/23/2026Q01010039-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification2
08/23/2026Q01010039-I1Open ↗
08/15/2026Q01420407-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026Q01420407-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q01420407-I1Open ↗