← Back
QUEENS
95-14 150 STREET
QUEENS · BIN 4626243
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
Building Lifecycle
All (39)Filed (6)Objection (3)Special Inspection (30)
09/09/2026
Objection raised — Other
08/27/2026
Objection raised — Other
08/24/2026
Filed — New Building
STRUCTURAL WORK FILED IN CONJUNCTION WITH NB Q01427888-I1
Q01427888-S5
08/21/2026
Filed — New Building
STRUCTURAL WORK FILED IN CONJUNCTION WITH NB Q01427888-I1
Q01427888-S4
08/20/2026
Objection raised — Other
08/19/2026
Filed — New Building
STRUCTURAL WORK FILED IN CONJUNCTION WITH NB Q01427888-I1
Q01427888-S6
08/18/2026
Filed — New Building
STRUCTURAL WORK FILED IN CONJUNCTION WITH NB Q01427888-I1
Q01427888-S2
08/14/2026
Special inspection requirement — Concrete - Cast-In-Place
08/14/2026
Special inspection requirement — Post-installed Anchors
08/14/2026
Special inspection requirement — Prestressed Rock and Soil Anchors
08/14/2026
Special inspection requirement — Structural Steel - Details
08/14/2026
Special inspection requirement — Subgrade Inspections
08/14/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
08/14/2026
Special inspection requirement — Structural Steel - Welding
08/11/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
08/11/2026
Special inspection requirement — Duct leakage testing, insulation and design
08/11/2026
Special inspection requirement — Electrical motors and elevators
08/11/2026
Special inspection requirement — Maintenance information
08/11/2026
Special inspection requirement — Interior lighting power
08/11/2026
Special inspection requirement — Exterior lighting power
08/11/2026
Special inspection requirement — HVAC-R and service water heating equipment
08/11/2026
Special inspection requirement — Metering
08/11/2026
Special inspection requirement — HVAC-R and service water heating system controls
08/11/2026
Special inspection requirement — Lighting controls
08/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/11/2026
Special inspection requirement — Energy Code Compliance Inspections
08/11/2026
Special inspection requirement — Emergency and Standby Power Systems (Generator)
08/11/2026
Special inspection requirement — Shutoff dampers
08/11/2026
Special inspection requirement — Lighting in dwelling units
08/07/2026
Filed — New Building
STRUCTURAL WORK FILED IN CONJUNCTION WITH NB Q01427888-I1
Q01427888-S3
08/05/2026
Special inspection requirement — Concrete - Cast-In-Place
08/05/2026
Special inspection requirement — Structural Steel - Details
08/05/2026
Special inspection requirement — Structural Steel - Welding
08/05/2026
Special inspection requirement — Subgrade Inspections
08/02/2026
Filed — New Building
STRUCTURAL WORK FILED IN CONJUNCTION WITH NB Q01427888-I1
Q01427888-I1
08/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
08/02/2026
Special inspection requirement — Protection of exposed foundation insulation
08/02/2026
Special inspection requirement — Vestibules
08/02/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Nothing on file for this building.
1 project · most recent 08/24/2026
Concrete
FiledStatusContractorScope
08/24/2026——Concrete
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
08/14/2026Concrete - Cast-In-Place—special
08/14/2026Post-installed Anchors—special
08/14/2026Prestressed Rock and Soil Anchors—special
08/14/2026Structural Steel - Details—special
08/14/2026Subgrade Inspections—special
08/14/2026Subsurface Investigations (Borings/Test Pits)—special
08/14/2026Structural Steel - Welding—special
08/11/2026HVAC-R and service water piping design and insulation—energy_progress
08/11/2026Duct leakage testing, insulation and design—energy_progress
08/11/2026Electrical motors and elevators—energy_progress
08/11/2026Maintenance information—energy_progress
08/11/2026Interior lighting power—energy_progress
08/11/2026Exterior lighting power—energy_progress
08/11/2026HVAC-R and service water heating equipment—energy_progress
08/11/2026Metering—energy_progress
08/11/2026HVAC-R and service water heating system controls—energy_progress
08/11/2026Lighting controls—energy_progress
08/11/2026Fire-Resistant Penetrations and Joints—special
08/11/2026Energy Code Compliance Inspections—progress
08/11/2026Emergency and Standby Power Systems (Generator)—special
08/11/2026Shutoff dampers—energy_progress
08/11/2026Lighting in dwelling units—energy_progress
08/05/2026Concrete - Cast-In-Place—special
08/05/2026Structural Steel - Details—special
08/05/2026Structural Steel - Welding—special
Latest 25 of 50.
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/16/2026Q01427888-S2Request digital key ↗
08/16/2026Q01427888-I1Request digital key ↗
08/16/2026Q01427888-S5Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026Q01427888-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026Q01427888-I1Open ↗
08/16/2026Q01427888-S3Open ↗
▸Other Documents1
▸DOB NOWSite Survey: Initial1
08/16/2026Q01427888-I1Open ↗