← Back
Church, synagogue, chapel
320 MONTGOMERY AVENUE
STATEN ISLAND · BIN 5000187
💬 Discuss this project
1997Year Built
2Stories
M1Building Class
C4-2Zoning
9,266 sfGross Floor Area
1Units
3 Open Violations ▸FDNY Report ↗
Church, synagogue, chapel · Owner of record: BRIGHTON HGTS REF CHURCH · 13,848 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRIGHTON HEIGHTS REFORMED CHURCH603/22/2026
BRIGHTON HGTS REF CHURCH203/22/2026
BRIGHTON HEIGHTS CHURCH103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PERMANENT ENGINEERING P.C.102/29/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SCARAN OIL SERVICE INCGeneral Contractor203/21/2026
MACKENZIE, DOUGLASElectrical103/21/2026
RODRIGUEZ, GIANFRANCOElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RELIANCE ENGINEERING, P.C322102/29/2024
Building Lifecycle
All (26)Filed (1)Permit Issued (1)Signed Off (1)Violation (19)Special Inspection (4)
03/19/2024
Signed off — Alteration
WORK TYPE FILED FOR DIRECT REPLACEMENT OF 6 HVAC UNITS AT EXISTING ROOF OF BUILDING CONNECTING TO EX. DUCT SYSTEM AND PIPING. PREVIOUSLY APPROVED UNDER APPLICATION #500271458 APPLICATION FILED TO OBTAIN CERTIFICATE OF COMPLIANCE (EQUIPMENT USE PERMITS)
S00998392-I1
03/13/2024
Permit issued — Mechanical Systems
S00998392-I1-MS
02/29/2024
Filed — Alteration
WORK TYPE FILED FOR DIRECT REPLACEMENT OF 6 HVAC UNITS AT EXISTING ROOF OF BUILDING CONNECTING TO EX. DUCT SYSTEM AND PIPING. PREVIOUSLY APPROVED UNDER APPLICATION #500271458 APPLICATION FILED TO OBTAIN CERTIFICATE OF COMPLIANCE (EQUIPMENT USE PERMITS)
S00998392-I1
02/22/2024
Special inspection requirement — Heating Systems
Ralph Giorgio
02/22/2024
Special inspection requirement — Energy Code Compliance Inspections
Ralph Giorgio
01/30/2024
Special inspection requirement — Mechanical Systems
Ralph Giorgio
01/30/2024
Special inspection requirement — Final
Ralph Giorgio
02/20/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/21/2019
Violation issued (ECB, closed)
Construction
02/28/2018
Violation issued (ECB, closed)
Elevators
01/26/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/27/2017
Violation issued (FDNY_NOV, closed)
10/13/2017
Violation issued (FDNY_NOV, closed)
12/01/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/24/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/03/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/04/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/19/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/08/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/10/2000
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/14/1998
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
07/01/1996
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1996
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/30/1994
Violation issued (DOB, closed)
VPW*-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-DISMISSED
06/29/1993
Violation issued (FDNY_NOV, closed)
10/16/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offSCARAN OIL SERVICE INC03/13/2024
BISOTISSUEDKANG SUK CONSTRUCTION INC10/17/2014
BISOTISSUEDDIFFENDALE & KUBEC06/18/2002
BISOTISSUEDPETER STEVEN QUANCI & ASSOCIATES12/07/2001
BISPLISSUEDSPECALIZED PLUMBING08/09/2001
BISEQISSUEDTHE BRIGHTON HGTS REFORMEDCHURCH09/15/1999
BIS—ISSUEDBRIGHTON HEIGHTS REFORMED CHURCH09/15/1999
BISEQISSUEDJTG & SONS SCAFFOLDING CO.,INC.12/07/1998
BISPLISSUEDSPECIALIZED PLBG INC.09/15/1998
BIS—ISSUEDBRIGHTON HEIGHTS REFORMED CHURCH05/27/1998
BIS—ISSUEDTHE BRIGHTON HGTS REFORMEDCHURCH11/10/1997
BISEQISSUEDA. RUSSO WRECKING INC.10/02/1996
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
02/22/2024Heating SystemsRalph Giorgiospecial
02/22/2024Energy Code Compliance InspectionsRalph Giorgioprogress
01/30/2024Mechanical SystemsRalph Giorgiospecial
01/30/2024FinalRalph Giorgioprogress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026S00998392-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
09/05/2014540054359Open ↗
06/16/2014520198429Open ↗
▸BISWORK PERMIT APPLICATION1
10/22/2014520198429Open ↗
▸Seals & Professional Certifications6
▸BISAPPLICANT OWNER SIGNATURE1
08/27/2014540054359Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/16/2014520198429Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
06/16/2014520198429Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026S00998392-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026S00998392-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026S00998392-I1Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
08/28/2014540054359Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/04/2014540054359Open ↗
08/28/2014540054359Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/28/2014540054359Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
06/16/2014520198429Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter1
08/13/2026S00998392-I1Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
08/28/2014540054359Open ↗
06/16/2014520198429Open ↗
▸BISCIVIL PENALTY AFFADAVIT/REQUEST1
08/28/2014540054359Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
08/28/2014540054359Open ↗
▸BISADDITIONAL INFORMATION1
09/04/2014540054359Open ↗