← Back
Two stories - detached, small or mid-size
271 SOUTH GREENLEAF AVE
STATEN ISLAND · BIN 5010434
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R3XZoning
1,246 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,159 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction3p · 1 filing · 13 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHARLES A. MAGRINO, AIA204/20/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TROOST BROS INCGeneral Contractor107/23/2026
CAPITAL CONTR P&H CORPPlumbing108/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ISLAND ENGINEERING ASSOCI264104/20/2026
Building Lifecycle
All (11)Filed (2)Permit Issued (2)Special Inspection (7)
08/27/2026
Permit issued — Plumbing
S01382695-S1-PL
07/22/2026
Permit issued — General Construction
S01382695-I1-GC-CX
04/20/2026
Filed — Alteration
REVISE PARTITIONS ON FIRST FLOOR AND INSTALL NEW GIRDER. MISCELLANEOUS WINDOW CHANGES.
S01382695-S1
04/20/2026
Filed — Alteration
REVISE PARTITIONS ON FIRST FLOOR AND INSTALL NEW GIRDER. MISCELLANEOUS WINDOW CHANGES.
S01382695-I1
04/10/2026
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM DURDEN, P.E.
04/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
WILLIAM DURDEN, P.E.
04/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
WILLIAM DURDEN, P.E.
04/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM DURDEN, P.E.
04/03/2026
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM DURDEN, P.E.
04/03/2026
Special inspection requirement — Structural Wood Frame
WILLIAM DURDEN, P.E.
04/03/2026
Special inspection requirement — Final
WILLIAM DURDEN, P.E.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCAPITAL CONTR P&H CORP08/27/2026
DOB NOWGeneral ConstructionPermit IssuedTROOST BROS INC07/22/2026
1 job · most recent 09/01/2026
General Wiring
FiledStatusContractorScope
09/01/2026Permit IssuedRIDGE ELECTRIC CORP.General Wiring
1 job · most recent 04/20/2026
Wood
FiledStatusContractorScope
04/20/2026Permit IssuedCAPITAL CONTR P&H CORPWood
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
04/10/2026Energy Code Compliance InspectionsWILLIAM DURDEN, P.E.progress
04/10/2026HVAC-R and service water piping design and insulationWILLIAM DURDEN, P.E.energy_progress
04/03/2026Structural Stability – Alterations of existing buildingsWILLIAM DURDEN, P.E.special
04/03/2026Fire-Resistant Penetrations and JointsWILLIAM DURDEN, P.E.special
04/03/2026Energy Code Compliance InspectionsWILLIAM DURDEN, P.E.progress
04/03/2026Structural Wood FrameWILLIAM DURDEN, P.E.progress
04/03/2026FinalWILLIAM DURDEN, P.E.progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026S01382695-I1Request digital key ↗
08/17/2026S01382695-S1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature5
09/25/2026S01382695-I1Open ↗
09/25/2026S01382695-I1Open ↗
09/25/2026S01382695-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026S01382695-S1Open ↗
08/17/2026S01382695-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/25/2026S01382695-I1Open ↗
09/25/2026S01382695-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026S01382695-I1Open ↗
08/17/2026S01382695-S1Open ↗