← Back
Two stories - detached, small or mid-size
170 WOOLLEY AVENUE
STATEN ISLAND · BIN 5011797
💬 Discuss this project
1955Year Built
2Stories
A1Building Class
R2Zoning
3,603 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 5,040 sf lot · 0.71 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingCivil
Floor 23p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Basement4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
J.B.I. CONSTRUCTION GROUP703/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOSEPH M. MORACE, A.I.A., ARCHITECT509/27/2024
ETRECTE LLC104/24/2024
WILLIAM MONTAGUE ENGINEER108/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PATRICIA L GASS1003/21/2026
J B I CONSTRUCTION GROUP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J.B.I. CONSTRUCTION GROUPGeneral Contractor1503/21/2026
MSB PLUMBING CONTRACTORSPlumbing307/08/2026
K.M.D MECHANICAL 1443 LLCFire Protection107/08/2026
QUALITY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SRA PLANNING & EXPEDITING5677309/27/2024
ETRECTE LLC8116104/24/2024
Building Lifecycle
All (66)Filed (7)Permit Issued (10)Signed Off (4)Violation (1)Inspection (12)Objection (2)Special Inspection (30)
12/19/2025
Inspection — Fail-Final Boiler Equipment Inspection
Fail
View inspection ↗
01/10/2025
Signed off — Alteration
PROPOSED 2" DOMESTIC WITH SP TAKE OFF
S00923004-I1
12/19/2024
Signed off — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-S2
12/13/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/27/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-P2
09/04/2024
Permit issued — Sprinklers
S00923004-I1-PL
05/17/2024
Signed off — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOF TOP. NO CHANGES TO THE USE EGRESS OR OCCUPANCY.
S01040495-I1
04/29/2024
Permit issued — Solar
S01040495-I1-SL
04/24/2024
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOF TOP. NO CHANGES TO THE USE EGRESS OR OCCUPANCY.
S01040495-I1
04/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VYACHESLAV NECHAYEV
04/23/2024
Special inspection requirement — Air barrier - visual inspection
VYACHESLAV NECHAYEV
04/23/2024
Special inspection requirement — Final
VYACHESLAV NECHAYEV
04/23/2024
Special inspection requirement — Energy Code Compliance Inspections
VYACHESLAV NECHAYEV
04/23/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
VYACHESLAV NECHAYEV
11/09/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-P1
10/26/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/24/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/20/2023
Permit issued — Plumbing
S00923004-I1-EW-SP
10/20/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/16/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/11/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-S1
10/05/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/28/2023
Permit issued — Plumbing
S00724062-S2-PL
08/22/2023
Filed — Alteration
PROPOSED 2" DOMESTIC WITH SP TAKE OFF
S00923004-I1
08/22/2023
Special inspection requirement — Sprinkler Systems
WILLIAM MONTAGUE
08/16/2023
Permit issued — Construction Fence
S00724062-S1-FN
08/16/2023
Permit issued — Foundation
S00724062-I1-GC-CX
01/17/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
01/12/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/09/2023
Permit issued — Plumbing
S69862295-S2-PL
12/09/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/03/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/15/2022
Permit issued — Plumbing
S00724062-S2-PL
07/09/2022
Permit issued — Earth Work
S00724062-I1-GC-CX
06/13/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-S2
06/09/2022
Permit issued — Construction Fence
S00724062-S1-FN
06/02/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-S1
06/01/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
WILLIAM MONTAGUE
05/23/2022
Objection raised — Scope
05/23/2022
Objection resolved — Addressed
05/02/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF 8' HIGH TEMPORARY PLYWOOD CONSTRUCTION FENCE.
S00724062-I1
04/28/2022
Special inspection requirement — Subgrade Inspections
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Concrete - Cast-In-Place
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Fire-Resistance Rated Construction
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Structural Wood Frame
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Fenestration air leakage
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Fenestration areas
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Fireplaces
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — HVAC-R and service water heating system controls
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Air barrier — testing
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Interior lighting power
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — HVAC-R and service water heating equipment
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Air barrier - visual inspection
WILLIAM MONTAGUE
04/28/2022
Special inspection requirement — Maintenance information
WILLIAM MONTAGUE
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offMSB PLUMBING CONTRACTORS09/04/2024
DOB NOWSolarSigned-offJ.B.I. CONSTRUCTION GROUP04/29/2024
DOB NOWPlumbingSigned-offK.M.D MECHANICAL 1443 LLC10/20/2023
DOB NOWPlumbingSigned-offMSB PLUMBING CONTRACTORS09/28/2023
DOB NOWConstruction FenceSigned-offJ.B.I. CONSTRUCTION GROUP08/16/2023
DOB NOWFoundationPermit IssuedJ.B.I. CONSTRUCTION GROUP08/16/2023
DOB NOWPlumbingSigned-offQUALITY PLUMBING, INC01/09/2023
DOB NOWPlumbingSigned-offMSB PLUMBING CONTRACTORS07/15/2022
DOB NOWEarth WorkPermit IssuedJ.B.I. CONSTRUCTION GROUP07/09/2022
DOB NOWConstruction FenceSigned-offJ.B.I. CONSTRUCTION GROUP06/09/2022
BIS—ISSUEDN/A11/13/1997
1 project · most recent 09/27/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/27/2024Signed-offMSB PLUMBING CONTRACTORSGas, Storm, Water/Sanitary
4 projects · most recent 04/12/2024
General Wiring
FiledStatusContractorScope
04/12/2024CompleteJSP ELECTL CNTNG CORP—
03/27/2024CompleteAQUATECH MECH,PLBG & ELEC1 meters
10/30/2023CompleteMANGI ELECTRICAL CORPGeneral Wiring
07/27/2022CompleteMANGI ELECTRICAL CORP1 meters, 1 new_meters
1 project · most recent 09/27/2024
Concrete Wood
FiledStatusContractorScope
09/27/2024Signed-offMSB PLUMBING CONTRACTORSConcrete, Wood
1 project · most recent 09/27/2024
Fence
FiledStatusContractorScope
09/27/2024Signed-offMSB PLUMBING CONTRACTORSFence
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
12/19/2025Fail-Final Boiler Equipment InspectionFailView ↗
12/13/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/26/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/24/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/20/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/16/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/05/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/17/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
01/12/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/09/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/09/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/03/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
04/23/2024Fire-Resistant Penetrations and JointsVYACHESLAV NECHAYEVspecial
04/23/2024Air barrier - visual inspectionVYACHESLAV NECHAYEVenergy_progress
04/23/2024FinalVYACHESLAV NECHAYEVprogress
04/23/2024Energy Code Compliance InspectionsVYACHESLAV NECHAYEVprogress
04/23/2024Structural Stability – Alterations of existing buildingsVYACHESLAV NECHAYEVspecial
08/22/2023Sprinkler SystemsWILLIAM MONTAGUEspecial
06/01/2022Subsurface Investigations (Borings/Test Pits)WILLIAM MONTAGUEspecial
04/28/2022Subgrade InspectionsWILLIAM MONTAGUEspecial
04/28/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationWILLIAM MONTAGUEspecial
04/28/2022Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
04/28/2022Concrete - Cast-In-PlaceWILLIAM MONTAGUEspecial
04/28/2022Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
04/28/2022Fire-Resistance Rated ConstructionWILLIAM MONTAGUEprogress
04/28/2022Structural Wood FrameWILLIAM MONTAGUEprogress
04/28/2022Fenestration air leakageWILLIAM MONTAGUEenergy_progress
04/28/2022Fenestration and door U-factor and product ratingsWILLIAM MONTAGUEenergy_progress
04/28/2022Fenestration areasWILLIAM MONTAGUEenergy_progress
04/28/2022FireplacesWILLIAM MONTAGUEenergy_progress
04/28/2022HVAC-R and service water heating system controlsWILLIAM MONTAGUEenergy_progress
04/28/2022Air barrier — testing WILLIAM MONTAGUEenergy_progress
04/28/2022Interior lighting powerWILLIAM MONTAGUEenergy_progress
04/28/2022HVAC-R and service water piping design and insulationWILLIAM MONTAGUEenergy_progress
04/28/2022HVAC-R and service water heating equipmentWILLIAM MONTAGUEenergy_progress
04/28/2022Air barrier - visual inspectionWILLIAM MONTAGUEenergy_progress
04/28/2022Maintenance informationWILLIAM MONTAGUEenergy_progress
Latest 25 of 35.
▾Documents — 84 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/24/2026S00724062-P2Request digital key ↗
08/24/2026S00724062-S2Request digital key ↗
08/24/2026S00724062-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
12/13/2024540217022Open ↗
02/09/2024500249787Open ↗
04/12/2022540217022Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
04/12/2022540217022Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00724062-P2Open ↗
08/13/2026S00724062-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00724062-I1Open ↗
08/13/2026S00724062-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00724062-I1Open ↗
▸Seals & Professional Certifications42
▸DOB NOWProgress Inspector Seal & Signature24
08/27/2026S00724062-I1Open ↗
08/27/2026S00724062-I1Open ↗
08/27/2026S00724062-I1Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
08/27/2026S00724062-I1Open ↗
08/27/2026S00724062-I1Open ↗
08/27/2026S00724062-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/24/2026S00724062-P2Open ↗
08/24/2026S00724062-S2Open ↗
08/24/2026S00724062-P1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/12/2022540217022Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
04/12/2022540217022Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S00724062-P2Open ↗
08/13/2026S00724062-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/24/2026S00724062-S1Open ↗
08/24/2026S00724062-S2Open ↗
08/24/2026S00724062-P2Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026S00724062-I1Open ↗
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT2
08/13/2026S00724062-P2Open ↗
08/13/2026S00724062-I1Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
04/12/2022540217022Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00724062-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026S00724062-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff2
12/18/2024540217022Open ↗
04/12/2022540217022Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01040495-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
04/12/2022540217022Open ↗
▸Other Documents8
▸BISBPP - SUPPORTING DOCUMENTATION2
12/18/2024540217022Open ↗
04/12/2022540217022Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00724062-P2Open ↗
08/13/2026S00724062-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/24/2026S00724062-P2Open ↗
08/15/2026S00724062-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026S00724062-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026S00724062-I1Open ↗