← Back
Two stories - detached, small or mid-size
19 O'CONNOR AVENUE
STATEN ISLAND · BIN 5012492
💬 Discuss this project
1950Year Built
2Stories
A1Building Class
R3-2Zoning
2,160 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,000 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
Structural
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1p · 1 filing · 20 docs
Floor 1Under Construction1p · 1 filing · 20 docs
CellarUnder Construction1p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHARLES A. MAGRINO, AIA606/15/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TROOST BROS INCGeneral Contractor204/09/2026
RICHMOND PLBG & HEATINGPlumbing206/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ISLAND ENGINEERING ASSOCI264203/09/2026
Building Lifecycle
All (15)Filed (6)Permit Issued (4)Inspection (5)
08/11/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/11/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/25/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/15/2026
Filed — Alteration CO
MODIFY FIRST FLOOR AND CELLAR BATHROOMS AND ADD GAS FIREPLACE ON FIRST FLOOR. REMOVE GAS RANGE IN CELLAR ADD EMERGENCY GENERATOR IN SIDE YARD.
S01269809-P3
06/08/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/08/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/08/2026
Permit issued — Plumbing
S01269809-S1-PL
05/04/2026
Permit issued — Plumbing
S01269809-S1-PL
03/24/2026
Permit issued — Construction Fence
S01269809-S2-FN
03/24/2026
Permit issued — Foundation
S01269809-I1-GC-CX
03/09/2026
Filed — Alteration CO
MODIFY FIRST FLOOR AND CELLAR BATHROOMS AND ADD GAS FIREPLACE ON FIRST FLOOR. REMOVE GAS RANGE IN CELLAR ADD EMERGENCY GENERATOR IN SIDE YARD.
S01269809-P1
03/09/2026
Filed — Alteration CO
MODIFY FIRST FLOOR AND CELLAR BATHROOMS AND ADD GAS FIREPLACE ON FIRST FLOOR. REMOVE GAS RANGE IN CELLAR ADD EMERGENCY GENERATOR IN SIDE YARD.
S01269809-P2
08/28/2025
Filed — Alteration CO
MODIFY FIRST FLOOR AND CELLAR BATHROOMS AND ADD GAS FIREPLACE ON FIRST FLOOR. REMOVE GAS RANGE IN CELLAR ADD EMERGENCY GENERATOR IN SIDE YARD.
S01269809-I1
08/28/2025
Filed — Alteration CO
MODIFY FIRST FLOOR AND CELLAR BATHROOMS AND ADD GAS FIREPLACE ON FIRST FLOOR. REMOVE GAS RANGE IN CELLAR ADD EMERGENCY GENERATOR IN SIDE YARD.
S01269809-S2
08/28/2025
Filed — Alteration CO
MODIFY FIRST FLOOR AND CELLAR BATHROOMS AND ADD GAS FIREPLACE ON FIRST FLOOR. REMOVE GAS RANGE IN CELLAR ADD EMERGENCY GENERATOR IN SIDE YARD.
S01269809-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRICHMOND PLBG & HEATING05/08/2026
DOB NOWPlumbingSigned-offRICHMOND PLBG & HEATING05/04/2026
DOB NOWConstruction FenceSigned-offTROOST BROS INC03/24/2026
DOB NOWFoundationPermit IssuedTROOST BROS INC03/24/2026
1 project · most recent 06/15/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/15/2026Signed-offRICHMOND PLBG & HEATINGGas, Water/Sanitary
2 projects · most recent 08/23/2026
General Wiring
FiledStatusContractorScope
08/23/2026Permit IssuedRIDGE ELECTRIC CORP.General Wiring
10/16/2019CompleteVENTURE HOME SOLAR LLC—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/11/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/11/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/25/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/08/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/08/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
06/15/2026Energy Code Compliance InspectionsWILLIAM DURDEN, P.E.progress
06/15/2026HVAC-R and service water piping design and insulationWILLIAM DURDEN, P.E.energy_progress
03/18/2026Concrete - Cast-In-PlaceWILLIAM DURDEN, P.E.special
03/18/2026Fire-Resistant Penetrations and JointsWILLIAM DURDEN, P.E.special
03/18/2026Subgrade InspectionsWILLIAM DURDEN, P.E.special
03/18/2026Structural Stability – Alterations of existing buildingsWILLIAM DURDEN, P.E.special
03/18/2026Footing and FoundationWILLIAM DURDEN, P.E.progress
03/18/2026FinalWILLIAM DURDEN, P.E.progress
03/18/2026Energy Code Compliance InspectionsWILLIAM DURDEN, P.E.progress
03/18/2026Structural Wood FrameWILLIAM DURDEN, P.E.progress
03/18/2026FireplacesWILLIAM DURDEN, P.E.energy_progress
03/18/2026Insulation placement and R valuesWILLIAM DURDEN, P.E.energy_progress
03/18/2026Interior lighting powerWILLIAM DURDEN, P.E.energy_progress
03/18/2026Fenestration air leakageWILLIAM DURDEN, P.E.energy_progress
03/18/2026Fenestration areasWILLIAM DURDEN, P.E.energy_progress
03/18/2026Permanent certificateWILLIAM DURDEN, P.E.energy_progress
03/18/2026Air barrier - visual inspectionWILLIAM DURDEN, P.E.energy_progress
03/18/2026Air barrier — testing WILLIAM DURDEN, P.E.energy_progress
03/18/2026Fenestration and door U-factor and product ratingsWILLIAM DURDEN, P.E.energy_progress
03/06/2026Concrete - Cast-In-PlaceWILLIAM DURDEN, P.E.special
03/06/2026Structural Stability – Alterations of existing buildingsWILLIAM DURDEN, P.E.special
03/06/2026Fire-Resistant Penetrations and JointsWILLIAM DURDEN, P.E.special
03/06/2026Subgrade InspectionsWILLIAM DURDEN, P.E.special
03/06/2026Energy Code Compliance InspectionsWILLIAM DURDEN, P.E.progress
03/06/2026FinalWILLIAM DURDEN, P.E.progress
Latest 25 of 38.
▾Documents — 92 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/17/2026S01269809-P3Request digital key ↗
08/17/2026S01269809-P1Request digital key ↗
08/17/2026S01269809-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
10/14/2019540169850Open ↗
08/20/2015520243638Open ↗
▸BISWORK PERMIT APPLICATION1
10/14/2019540169850Open ↗
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram3
08/17/2026S01269809-I1Open ↗
08/13/2026S01269809-I1Open ↗
08/13/2026S01269809-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026S01269809-I1Open ↗
08/13/2026S01269809-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S01269809-I1Open ↗
08/13/2026S01269809-P1Open ↗
▸Seals & Professional Certifications32
▸DOB NOWProgress Inspector Seal & Signature14
09/16/2026S01269809-I1Open ↗
09/16/2026S01269809-I1Open ↗
09/16/2026S01269809-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/16/2026S01269809-I1Open ↗
09/16/2026S01269809-I1Open ↗
09/16/2026S01269809-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/17/2026S01269809-P1Open ↗
08/17/2026S01269809-P3Open ↗
08/17/2026S01269809-P2Open ↗
Showing 3 of 6 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/14/2019540169850Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/14/2019540169850Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/14/2019540169850Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/17/2015520243638Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/17/2015520243638Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist2
08/17/2026S01269809-I1Open ↗
08/17/2026S01269809-P1Open ↗
▸BISSTREET TREE CHECKLIST1
07/17/2015520243638Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
10/14/2019540169850Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/17/2026S01269809-P3Open ↗
08/17/2026S01269809-P2Open ↗
08/17/2026S01269809-P1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/14/2019540169850Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
11/07/2019540169850Open ↗
10/14/2019540169850Open ↗
10/14/2019540169850Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/07/2019540169850Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/14/2019540169850Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
11/07/2019540169850Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/17/2015520243638Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/14/2019540169850Open ↗
▸Inspections & Test Reports5
▸BISTECHNICAL REPORT: RESPONSIBILITY4
11/07/2019540169850Open ↗
11/07/2019540169850Open ↗
10/14/2019540169850Open ↗
Showing 3 of 4 on file for this type
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
10/14/2019540169850Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/07/2019540169850Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/17/2015520243638Open ↗
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
11/07/2019540169850Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
11/07/2019540169850Open ↗
10/14/2019540169850Open ↗
07/17/2015520243638Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
09/01/2015520243638Open ↗
07/17/2015520243638Open ↗
▸BISEFILING COVER SHEET1
07/17/2015520243638Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/14/2019540169850Open ↗
▸Other Documents9
▸DOB NOWPlot Diagram2
08/13/2026S01269809-P1Open ↗
08/13/2026S01269809-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/17/2026S01269809-P1Open ↗
08/17/2026S01269809-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S01269809-I1Open ↗
08/13/2026S01269809-P1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026S01269809-P1Open ↗
08/13/2026S01269809-I1Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
10/14/2019540169850Open ↗