← Back
Two stories - detached, small or mid-size
301 HOWARD AVENUE
STATEN ISLAND · BIN 5015844
💬 Discuss this project
1940Year Built
2Stories
A1Building Class
R1-1Zoning
1,880 sfGross Floor Area
1Units
Rent Stabilized5 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · 17,400 sf lot · 0.11 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction45p · 1 filing · 20 docs
Floor 2Under Construction47p · 1 filing · 20 docs
Floor 1Under Construction48p · 1 filing · 20 docs
CellarUnder Construction46p · 1 filing · 20 docs
BasementUnder Construction44p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NTD ENGINEERING CONSULTANT LLC609/04/2025
S M TAM ARCHITECT, PLLC306/25/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S M TAM ARCHITECT1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RECORD GROUP INCGeneral Contractor707/08/2026
UL ELECTRICAL CORP.Electrical103/22/2026
IMPACT BUILDERS CORPGeneral Contractor104/09/2026
CHARLES J. DEHART JR P&HPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519108/19/2025
WORLD DESIGN ARCHITECTURE9323306/13/2025
Building Lifecycle
All (121)Filed (9)Permit Issued (7)Violation (25)Inspection (4)Objection (46)Special Inspection (30)
08/26/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/01/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
06/24/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/05/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/01/2026
Permit issued — Plumbing
S00981474-S5-PL
04/21/2026
Permit issued — General Construction
S00981474-I1-GC
11/26/2025
Violation issued (HPD, open)
I
10/09/2025
Permit issued — Support of Excavation
S00981474-S1-SE
10/09/2025
Permit issued — Foundation
S00981474-S2-FO
10/08/2025
Permit issued — Structural
S00981474-S3-ST
10/08/2025
Objection resolved — Addressed
10/08/2025
Objection resolved — Addressed
09/19/2025
Objection resolved — Addressed
09/04/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S7
08/28/2025
Objection raised — Scope
08/28/2025
Objection raised — Energy
08/28/2025
Objection raised — Structural
08/21/2025
Special inspection requirement — Sprinkler Systems
08/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/19/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S5
08/19/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S4
07/20/2025
Objection resolved — Addressed
07/14/2025
Permit issued — Construction Fence
S00981474-S6-FN
07/09/2025
Special inspection requirement — Subgrade Inspections
William Alicea
07/07/2025
Special inspection requirement — HVAC-R and service water heating system controls
JEFFREY BELL
07/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
07/07/2025
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
07/07/2025
Special inspection requirement — HVAC-R and service water heating equipment
JEFFREY BELL
07/07/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
JEFFREY BELL
07/07/2025
Special inspection requirement — Maintenance information
JEFFREY BELL
07/02/2025
Objection resolved — Addressed
07/01/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
STEVE LIN
06/30/2025
Objection resolved — Addressed
06/30/2025
Special inspection requirement — Concrete - Cast-In-Place
William Alicea
06/30/2025
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
06/30/2025
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
06/30/2025
Special inspection requirement — Concrete - Cast-In-Place
William Alicea
06/30/2025
Special inspection requirement — Structural Steel - High Strength Bolting
William Alicea
06/30/2025
Special inspection requirement — Structural Steel - Welding
William Alicea
06/27/2025
Objection raised — Admin
06/27/2025
Objection raised — Inspections
06/25/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S6
06/24/2025
Objection raised — Admin
06/23/2025
Permit issued — General Construction
S00981474-I1-GC
06/13/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S2
06/13/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S3
06/12/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED TEMPORARY CONSTRUCTION FENCE @ GROUND FLOOR. THE FENCE IS OUTSIDE OF PROPERTY LINE WITHIN 3 FEET ONLY BEYOND THE PROPERTY LINE.
S00981474-S1
06/10/2025
Special inspection requirement — Structural Steel - Details
William Alicea
05/23/2025
Special inspection requirement — Metering
William Alicea
05/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
05/23/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
05/23/2025
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
05/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
William Alicea
05/23/2025
Special inspection requirement — Fenestration areas
William Alicea
05/23/2025
Special inspection requirement — Lighting in dwelling units
William Alicea
05/23/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
William Alicea
05/23/2025
Special inspection requirement — Insulation placement and R values
William Alicea
05/23/2025
Special inspection requirement — Air barrier - visual inspection
William Alicea
05/23/2025
Special inspection requirement — Exterior lighting power
William Alicea
05/23/2025
Special inspection requirement — Interior lighting power
William Alicea
Latest 60 of 121 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCHARLES J. DEHART JR P&H06/01/2026
DOB NOWGeneral ConstructionPermit IssuedRECORD GROUP INC04/21/2026
DOB NOWSupport of ExcavationPermit IssuedRECORD GROUP INC10/09/2025
DOB NOWFoundationPermit IssuedRECORD GROUP INC10/09/2025
DOB NOWStructuralPermit IssuedRECORD GROUP INC10/08/2025
DOB NOWConstruction FencePermit IssuedIMPACT BUILDERS CORP07/14/2025
DOB NOWGeneral ConstructionPermit IssuedRECORD GROUP INC06/23/2025
1 project · most recent 09/04/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/04/2025Permit IssuedRECORD GROUP INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PURY-HP120TNU-A1 120,000 BTU · Vrf Outdoor ×1
Ventilation
Panasonic FV-0511VF1 50 CFM · Exhaust Fan ×6
FV-06VE1 40 CFM · Erv ×2
Broan EPD6136SS 200 CFM · Kitchen Exhaust ×2
1 project · most recent 09/04/2025
Sprinkler System
FiledStatusContractorScope
09/04/2025——Sprinkler System
1 project · most recent 09/04/2025
FiledStatusContractorScope
09/04/2025Permit IssuedCHARLES J. DEHART JR P&H—
1 project · most recent 07/18/2025
FiledStatusContractorScope
07/18/2025Permit IssuedUL ELECTRICAL CORP.1 meters
1 project · most recent 09/04/2025
Steel Concrete
FiledStatusContractorScope
09/04/2025Permit IssuedCHARLES J. DEHART JR P&HSteel, Concrete
1 project · most recent 09/04/2025
Fence
FiledStatusContractorScope
09/04/2025Permit IssuedCHARLES J. DEHART JR P&HFence
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
08/26/2026Pass-Final PL - UndergroundPassView ↗
07/01/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
06/24/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/05/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 52
DateRequirementInspectorRole
08/21/2025Sprinkler Systems—special
08/21/2025Fire-Resistant Penetrations and Joints—special
07/09/2025Subgrade InspectionsWilliam Aliceaspecial
07/07/2025HVAC-R and service water heating system controlsJEFFREY BELLenergy_progress
07/07/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
07/07/2025Energy Code Compliance InspectionsJEFFREY BELLprogress
07/07/2025HVAC-R and service water heating equipmentJEFFREY BELLenergy_progress
07/07/2025HVAC-R and service water piping design and insulationJEFFREY BELLenergy_progress
07/07/2025Maintenance informationJEFFREY BELLenergy_progress
07/01/2025Subsurface Investigations (Borings/Test Pits)STEVE LINspecial
06/30/2025Concrete - Cast-In-PlaceWilliam Aliceaspecial
06/30/2025Energy Code Compliance InspectionsWilliam Aliceaprogress
06/30/2025Energy Code Compliance InspectionsWilliam Aliceaprogress
06/30/2025Concrete - Cast-In-PlaceWilliam Aliceaspecial
06/30/2025Structural Steel - High Strength BoltingWilliam Aliceaspecial
06/30/2025Structural Steel - WeldingWilliam Aliceaspecial
06/10/2025Structural Steel - DetailsWilliam Aliceaspecial
05/23/2025MeteringWilliam Aliceaenergy_progress
05/23/2025Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
05/23/2025Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
05/23/2025Energy Code Compliance InspectionsWilliam Aliceaprogress
05/23/2025Fire-Resistance Rated ConstructionWilliam Aliceaprogress
05/23/2025Fenestration areasWilliam Aliceaenergy_progress
05/23/2025Lighting in dwelling unitsWilliam Aliceaenergy_progress
05/23/2025Fenestration and door U-factor and product ratingsWilliam Aliceaenergy_progress
Latest 25 of 52.
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/18/2026S00981474-S4Request digital key ↗
08/18/2026S00981474-S1Request digital key ↗
08/18/2026S00981474-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits1
▸BISBPP-5 - Authorization to the Department of Transportation1
05/01/2024540263329Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00981474-P1Open ↗
08/13/2026S00981474-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00981474-I1Open ↗
08/13/2026S00981474-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00981474-I1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/18/2026S00981474-S3Open ↗
08/18/2026S00981474-S2Open ↗
08/18/2026S00981474-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/24/2026S00981474-S2Open ↗
08/24/2026S00981474-S2Open ↗
08/24/2026S00981474-S5Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/24/2026S00981474-S2Open ↗
08/24/2026S00981474-S5Open ↗
08/24/2026S00981474-S5Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/18/2024540263329Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/18/2024540263329Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S00981474-P1Open ↗
08/13/2026S00981474-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00981474-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/18/2026S00981474-S3Open ↗
08/18/2026S00981474-S2Open ↗
08/18/2026S00981474-I1Open ↗
Showing 3 of 9 on file for this type
▸Inspections & Test Reports5
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/13/2026S00981474-S1Open ↗
08/13/2026S00981474-S2Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
03/18/2024540263329Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026S00981474-S2Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00981474-S2Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
05/01/2024540263329Open ↗
▸Filing & Intake Forms1
▸BISADDITIONAL INFORMATION1
05/01/2024540263329Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/13/2026S00981474-P1Open ↗
08/13/2026S00981474-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00981474-P1Open ↗
08/13/2026S00981474-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/18/2026S00981474-P1Open ↗
08/18/2026S00981474-I1Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
05/01/2024540263329Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
05/01/2024540263329Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026S00981474-S1Open ↗