← Back
Two family frame
428 SOUTH GANNON AVENUE
STATEN ISLAND · BIN 5019964
💬 Discuss this project
1970Year Built
1Stories
B2Building Class
R3-1Zoning
1,860 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 6,309 sf lot · 0.29 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 3 docs
1 job · most recent 03/01/2024
FiledStatusContractorScope
03/01/2024CompleteVILLAGE ELECTL CONTRS INC—
Building Lifecycle
All (21)Filed (3)Permit Issued (1)Signed Off (1)Violation (5)Special Inspection (11)
05/24/2024
Signed off — Alteration
S01014768-I1
05/14/2024
Special inspection requirement — Air barrier - visual inspection
DOYUN KIM
05/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
05/14/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
05/14/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
05/14/2024
Special inspection requirement — Final
JEFFREY BELL
05/11/2024
Filed — Alteration
S01014768-P1
05/11/2024
Special inspection requirement — Air barrier - visual inspection
DOYUN KIM
05/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
05/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
05/11/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
05/11/2024
Special inspection requirement — Final
JEFFREY BELL
03/19/2024
Permit issued — Solar
S01014768-I1-SL
03/08/2024
Filed — Alteration
S01014768-I1
09/02/2021
Filed — Alteration
TO RESOLVE VIOLATION #35530262X, 39036011N BY REMOVING EXTENSION SUN ROOM AND OBTAIN A PERMIT. FILED TO SUPERSEDE BIS# 520308998. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00587750-I1
09/02/2021
Special inspection requirement — Final
Seungchul Ok
06/23/2021
Violation issued (ECB, closed)
Construction
05/12/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/2021
Violation issued (ECB, closed)
Construction
02/09/2021
Violation issued (ECB, closed)
Construction
08/18/2017
Violation issued (ECB, closed)
Construction
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JBA205/11/2024
ECOPLUSDESIGN109/02/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KC EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SOLAR PRO INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415205/11/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSOLAR PRO INC03/19/2024
BISOTISSUEDNIC DESIGN MGMT INC09/26/2017
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
05/14/2024Air barrier - visual inspectionDOYUN KIMenergy_progress
05/14/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
05/14/2024Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
05/14/2024Energy Code Compliance InspectionsDOYUN KIMprogress
05/14/2024FinalJEFFREY BELLprogress
05/11/2024Air barrier - visual inspectionDOYUN KIMenergy_progress
05/11/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
05/11/2024Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
05/11/2024Energy Code Compliance InspectionsDOYUN KIMprogress
05/11/2024FinalJEFFREY BELLprogress
09/02/2021FinalSeungchul Okprogress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026S00587750-I1Request digital key ↗
08/21/2026S01014768-I1Request digital key ↗
08/21/2026S01014768-P1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/26/2017520308998Open ↗
▸BISWORK PERMIT APPLICATION1
09/26/2017520308998Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature7
08/31/2026S01014768-P1Open ↗
08/31/2026S01014768-P1Open ↗
08/31/2026S01014768-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026S01014768-P1Open ↗
08/31/2026S01014768-P1Open ↗
08/23/2026S01014768-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026S00587750-I1Open ↗
08/21/2026S01014768-P1Open ↗
08/21/2026S01014768-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/26/2017520308998Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/26/2017520308998Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/26/2017520308998Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
09/26/2017520308998Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026S01014768-P1Open ↗
08/21/2026S01014768-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/26/2017520308998Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
09/26/2017520308998Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01014768-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/26/2017520308998Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/29/2017520308998Open ↗