← Back
Two stories - detached, small or mid-size
732 WESTWOOD AVENUE
STATEN ISLAND · BIN 5020027
💬 Discuss this project
1970Year Built
2Stories
A1Building Class
R3-1Zoning
2,304 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,800 sf lot · 0.48 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
Floor 2Under Construction6p · 1 filing · 18 docs
Floor 1Under Construction5p · 1 filing · 18 docs
1 job · most recent 02/03/2022
Wood
FiledStatusContractorScope
02/03/2022Permit IssuedCAMBRIDGE REMODELING CORPWood
1 job · most recent 02/03/2022
Fence
FiledStatusContractorScope
02/03/2022Permit IssuedCAMBRIDGE REMODELING CORPFence
Building Lifecycle
All (11)Filed (3)Permit Issued (2)Inspection (1)Objection (2)Special Inspection (3)
06/18/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/01/2026
Permit issued — Construction Fence
S00546751-S2-FN
04/30/2026
Permit issued — Structural
S00546751-S3-ST
02/03/2022
Filed — Alteration
FILING FOR STRUCTURAL WORK IN CONJUNCTION WITH APPLICAITION S00546751-I1
S00546751-S3
02/03/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
MOHAMED MAHMOUD
02/03/2022
Special inspection requirement — Final
Feng Zhang
02/03/2022
Special inspection requirement — Structural Wood Frame
MOHAMED MAHMOUD
08/05/2021
Filed — Alteration
FILING FOR STRUCTURAL WORK IN CONJUNCTION WITH APPLICAITION S00546751-I1
S00546751-S2
07/14/2021
Objection raised — Scope
07/14/2021
Objection resolved — Addressed
06/25/2021
Filed — Alteration
FILING FOR STRUCTURAL WORK IN CONJUNCTION WITH APPLICAITION S00546751-I1
S00546751-I1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RAHMAN CONSULTING102/03/2022
THOMAS SALAZAR, LLC208/05/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CAMBRIDGE REMODELINGGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MSM ENGINEERING SERVICES,8449202/03/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedCAMBRIDGE REMODELING CORP05/01/2026
DOB NOWStructuralPermit IssuedCAMBRIDGE REMODELING CORP04/30/2026
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/18/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
02/03/2022Structural Stability – Alterations of existing buildingsMOHAMED MAHMOUDspecial
02/03/2022FinalFeng Zhangprogress
02/03/2022Structural Wood FrameMOHAMED MAHMOUDprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026S00546751-S2Request digital key ↗
08/25/2026S00546751-S3Request digital key ↗
08/15/2026S00546751-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S00546751-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026S00546751-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026S00546751-S3Open ↗
08/13/2026S00546751-I1Open ↗
08/13/2026S00546751-S2Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026S00546751-S3Open ↗
08/25/2026S00546751-S3Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026S00546751-S3Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026S00546751-I1Open ↗
08/13/2026S00546751-S3Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertification by Insurance Broker or Agency1
08/15/2026S00546751-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/15/2026S00546751-I1Open ↗
▸Other Documents3
▸DOB NOWAdditional Insured Authorizations1
08/15/2026S00546751-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00546751-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026S00546751-I1Open ↗