Two stories - detached, small or mid-size
151 CLINTON PLACE
STATEN ISLAND · BIN 5025892
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3AZoning
1,360 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: 151 CLINTON LLC · 3,563 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 211p · 1 filing · 20 docs
Floor 110p · 1 filing · 20 docs
Cellar7p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRANKLYN ESTRELLA ARCHITECT PLLC206/02/2026
PETER NYIAM312/12/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FRANKLYN ESTRELLA ARCHITECT PLLC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DONE RIGHT KITCHEN EXHAUSGeneral Contractor104/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PIBIEN ENGINEERS9656212/12/2025
Building Lifecycle
All (56)Filed (5)Permit Issued (2)Violation (1)Inspection (1)Objection (21)Special Inspection (26)
07/01/2026
Objection resolved — Addressed
06/30/2026
Objection resolved — Addressed
06/30/2026
Objection resolved — Addressed
06/30/2026
Objection resolved — Addressed
06/30/2026
Objection resolved — Addressed
06/30/2026
Objection resolved — Addressed
06/29/2026
Special inspection requirement — Electric vehicle service equipment requirements
06/24/2026
Objection raised — Zoning
06/24/2026
Objection raised — Zoning
06/24/2026
Objection raised — Structural
06/24/2026
Objection raised — Scope
06/02/2026
Filed — Alteration CO
APPLICATION FILED TO CONVERT EXISTING ONE FAMILY HOUSE INTO A TWO FAMILY HOUSE ALL AS PER PLANS FILED HERE WITH.
S01268142-S1
05/21/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/11/2026
Violation issued (ECB, open)
Construction
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Structural
02/09/2026
Objection raised — Structural
02/09/2026
Objection raised — Scope
02/09/2026
Objection raised — Structural
02/09/2026
Objection raised — Structural
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Zoning
01/26/2026
Filed — Alteration CO
APPLICATION FILED TO CONVERT EXISTING ONE FAMILY HOUSE INTO A TWO FAMILY HOUSE ALL AS PER PLANS FILED HERE WITH.
S01268142-I1
12/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PETER NYIAM
12/15/2025
Special inspection requirement — Final
PETER NYIAM
12/15/2025
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Interior lighting power
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Insulation placement and R values
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Permanent certificate
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Fenestration air leakage
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Fenestration areas
FRANKLYN ESTRELLA
12/15/2025
Special inspection requirement — Air barrier - visual inspection
FRANKLYN ESTRELLA
12/12/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW GAS PIPING, GAS BOILERS AND PLUMBING FIXTURES ALL AS PER PLANS FILED HEREWITH.
S01273913-P1
12/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/11/2025
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
12/11/2025
Special inspection requirement — Air barrier - visual inspection
12/11/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
12/11/2025
Special inspection requirement — Insulation placement and R values
12/11/2025
Special inspection requirement — Fenestration areas
12/11/2025
Special inspection requirement — Interior lighting power
12/11/2025
Special inspection requirement — Fenestration air leakage
12/11/2025
Special inspection requirement — Metering
12/11/2025
Special inspection requirement — Permanent certificate
12/11/2025
Special inspection requirement — Air barrier — testing
09/23/2025
Permit issued — Plumbing
S01273913-S1-PL
09/05/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW GAS PIPING, GAS BOILERS AND PLUMBING FIXTURES ALL AS PER PLANS FILED HEREWITH.
S01273913-S1
09/04/2025
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
09/04/2025
Special inspection requirement — HVAC-R and service water heating system controls
FRANKLYN ESTRELLA
09/04/2025
Special inspection requirement — HVAC-R and service water heating equipment
FRANKLYN ESTRELLA
09/04/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
FRANKLYN ESTRELLA
08/28/2025
Permit issued — General Construction
S01273913-I1-GC
08/20/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW GAS PIPING, GAS BOILERS AND PLUMBING FIXTURES ALL AS PER PLANS FILED HEREWITH.
S01273913-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedDPH PLUMBING & HTG CORP09/23/2025
DOB NOWGeneral ConstructionPermit IssuedDONE RIGHT KITCHEN EXHAUS08/28/2025
1 job · most recent 12/12/2025
Gas Water/Sanitary
FiledStatusContractorScope
12/12/2025Permit IssuedJMW PLUMBING, INCGas, Water/Sanitary
1 job · most recent 06/29/2025
FiledStatusContractorScope
06/29/2025Permit IssuedWCK ELECTRIC CORP.3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
05/21/2026Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
06/29/2026Electric vehicle service equipment requirements—energy_progress
12/15/2025Fire-Resistant Penetrations and JointsPETER NYIAMspecial
12/15/2025FinalPETER NYIAMprogress
12/15/2025Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
12/15/2025Interior lighting powerFRANKLYN ESTRELLAenergy_progress
12/15/2025Insulation placement and R valuesFRANKLYN ESTRELLAenergy_progress
12/15/2025Permanent certificateFRANKLYN ESTRELLAenergy_progress
12/15/2025Fenestration and door U-factor and product ratingsFRANKLYN ESTRELLAenergy_progress
12/15/2025Fenestration air leakageFRANKLYN ESTRELLAenergy_progress
12/15/2025Fenestration areasFRANKLYN ESTRELLAenergy_progress
12/15/2025Air barrier - visual inspectionFRANKLYN ESTRELLAenergy_progress
12/11/2025Fire-Resistant Penetrations and Joints—special
12/11/2025Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
12/11/2025Air barrier - visual inspection—energy_progress
12/11/2025Fenestration and door U-factor and product ratings—energy_progress
12/11/2025Insulation placement and R values—energy_progress
12/11/2025Fenestration areas—energy_progress
12/11/2025Interior lighting power—energy_progress
12/11/2025Fenestration air leakage—energy_progress
12/11/2025Metering—energy_progress
12/11/2025Permanent certificate—energy_progress
12/11/2025Air barrier — testing —energy_progress
09/04/2025Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
09/04/2025HVAC-R and service water heating system controlsFRANKLYN ESTRELLAenergy_progress
09/04/2025HVAC-R and service water heating equipmentFRANKLYN ESTRELLAenergy_progress
Latest 25 of 26.
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/18/2026S01273913-S1Request digital key ↗
08/17/2026S01273913-P1Request digital key ↗
08/17/2026S01273913-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S01268142-I1Open ↗
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature8
08/31/2026S01273913-S1Open ↗
08/31/2026S01273913-S1Open ↗
08/27/2026S01273913-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/18/2026S01273913-S1Open ↗
08/17/2026S01273913-P1Open ↗
08/17/2026S01273913-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026S01273913-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/18/2026S01273913-S1Open ↗
08/17/2026S01273913-P1Open ↗
08/17/2026S01273913-P2Open ↗
Showing 3 of 5 on file for this type
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026S01268142-I1Open ↗