← Back
Two stories - detached, small or mid-size
569 WATCHOGUE ROAD
STATEN ISLAND · BIN 5029688
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R3XZoning
2,700 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,904 sf lot · 0.46 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralFire Protection
Roof1p · 1 filing · 20 docs
Floor 21p · 1 filing · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar1p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LAWRENCE MANDARINO ARCHITECT506/24/2024
A TECH ENGINEERING NYC, PLLC.101/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
APRILE BONAMO FILING REP203/21/2026
A TECH ENGINEERING NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A. FONTANA & SONS LLCGeneral Contractor1107/08/2026
SUPERIOR PLUMBING & HEATINGPlumbing307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LAWRENCE MANDARINO ARCHIT724306/24/2024
Building Lifecycle
All (59)Filed (6)Permit Issued (8)Signed Off (4)Inspection (12)Special Inspection (29)
09/09/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
07/09/2024
Signed off — Alteration CO
addition of 10.0' concrete curb cut including 2-18" concrete splays
S00956133-S1
07/08/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
06/25/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Lawrence Mandarino
06/25/2024
Special inspection requirement — Wood – Prefabricated I-Joists
Lawrence Mandarino
06/25/2024
Special inspection requirement — Subgrade Inspections
Lawrence Mandarino
06/25/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Lawrence Mandarino
06/25/2024
Special inspection requirement — Final
Lawrence Mandarino
06/25/2024
Special inspection requirement — Footing and Foundation
Lawrence Mandarino
06/25/2024
Special inspection requirement — Fire-Resistance Rated Construction
Lawrence Mandarino
06/25/2024
Special inspection requirement — Concrete - Cast-In-Place
Lawrence Mandarino
06/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Lawrence Mandarino
06/25/2024
Special inspection requirement — Energy Code Compliance Inspections
Lawrence Mandarino
06/25/2024
Special inspection requirement — Structural Wood Frame
Lawrence Mandarino
06/25/2024
Special inspection requirement — Fenestration air leakage
Lawrence Mandarino
06/25/2024
Special inspection requirement — Electric vehicle service equipment requirements
Lawrence Mandarino
06/25/2024
Special inspection requirement — HVAC-R and service water heating system controls
Lawrence Mandarino
06/25/2024
Special inspection requirement — Air barrier - visual inspection
Lawrence Mandarino
06/25/2024
Special inspection requirement — Insulation placement and R values
Lawrence Mandarino
06/25/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Lawrence Mandarino
06/25/2024
Special inspection requirement — HVAC-R and service water heating equipment
Lawrence Mandarino
06/25/2024
Special inspection requirement — Maintenance information
Lawrence Mandarino
06/25/2024
Special inspection requirement — Permanent certificate
Lawrence Mandarino
06/25/2024
Special inspection requirement — Fenestration areas
Lawrence Mandarino
06/25/2024
Special inspection requirement — Metering
Lawrence Mandarino
06/24/2024
Filed — Alteration CO
addition of 10.0' concrete curb cut including 2-18" concrete splays
S00956133-P1
06/24/2024
Signed off — Alteration CO
addition of 10.0' concrete curb cut including 2-18" concrete splays
S00956133-S2
06/24/2024
Signed off — Alteration
INSTALLATION OF FIRE SPRINKLER SYSTEM WITH VALVES AND METERS FOR SAME
S00973563-I1
06/24/2024
Permit issued — Curb Cut
S00956133-S1-CC
06/21/2024
Filed — Alteration CO
addition of 10.0' concrete curb cut including 2-18" concrete splays
S00956133-S1
06/17/2024
Signed off — Alteration
8.0' high plywood construction fence installed inside of property lines.
S00965982-I1
06/03/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/30/2024
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
05/28/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/16/2024
Permit issued — Plumbing
S00956133-S2-PL
05/16/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/28/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/28/2024
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
03/28/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/25/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/04/2024
Permit issued — Plumbing
S00973563-I1-PL
02/12/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/05/2024
Permit issued — Plumbing
S00956133-S2-PL
01/31/2024
Permit issued — Structural
S00956133-I1-ST
01/30/2024
Permit issued — Structural
S00956133-I1-GC
01/29/2024
Permit issued — Foundation
S00956133-I1-FO
01/12/2024
Filed — Alteration
INSTALLATION OF FIRE SPRINKLER SYSTEM WITH VALVES AND METERS FOR SAME
S00973563-I1
12/12/2023
Filed — Alteration CO
addition of 10.0' concrete curb cut including 2-18" concrete splays
S00956133-S2
12/12/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Lawrence Mandarino
12/12/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Lawrence Mandarino
12/12/2023
Special inspection requirement — Energy Code Compliance Inspections
Lawrence Mandarino
12/12/2023
Special inspection requirement — HVAC-R and service water heating system controls
Lawrence Mandarino
12/12/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Lawrence Mandarino
12/12/2023
Special inspection requirement — Maintenance information
Lawrence Mandarino
12/12/2023
Special inspection requirement — HVAC-R and service water heating equipment
Lawrence Mandarino
12/08/2023
Filed — Alteration CO
addition of 10.0' concrete curb cut including 2-18" concrete splays
S00956133-I1
11/27/2023
Permit issued — Construction Fence
S00965982-I1-FN
11/21/2023
Filed — Alteration
8.0' high plywood construction fence installed inside of property lines.
S00965982-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offA. FONTANA & SONS LLC06/24/2024
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI05/16/2024
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI03/04/2024
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI02/05/2024
DOB NOWStructuralSigned-offA. FONTANA & SONS LLC01/31/2024
DOB NOWStructuralPermit IssuedA. FONTANA & SONS LLC01/30/2024
DOB NOWFoundationSigned-offA. FONTANA & SONS LLC01/29/2024
DOB NOWConstruction FenceSigned-offA. FONTANA & SONS LLC11/27/2023
1 project · most recent 06/24/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/24/2024Signed-offSUPERIOR PLUMBING & HEATIGas, Storm, Water/Sanitary
1 project · most recent 03/17/2024
General Wiring
FiledStatusContractorScope
03/17/2024CompleteS.T.K. ELECTRICAL CORP.General Wiring
1 project · most recent 06/24/2024
Concrete Wood
FiledStatusContractorScope
06/24/2024Signed-offA. FONTANA & SONS LLCConcrete, Wood
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
09/09/2024Fail-Final CND-Occupancy InspectionFailView ↗
07/08/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
06/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
05/30/2024Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
05/28/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/16/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/28/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/28/2024Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
03/28/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/25/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/12/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/12/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
06/25/2024Structural Stability – Alterations of existing buildingsLawrence Mandarinospecial
06/25/2024Wood – Prefabricated I-JoistsLawrence Mandarinospecial
06/25/2024Subgrade InspectionsLawrence Mandarinospecial
06/25/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationLawrence Mandarinospecial
06/25/2024FinalLawrence Mandarinoprogress
06/25/2024Footing and FoundationLawrence Mandarinoprogress
06/25/2024Fire-Resistance Rated ConstructionLawrence Mandarinoprogress
06/25/2024Concrete - Cast-In-PlaceLawrence Mandarinospecial
06/25/2024Fire-Resistant Penetrations and JointsLawrence Mandarinospecial
06/25/2024Energy Code Compliance InspectionsLawrence Mandarinoprogress
06/25/2024Structural Wood FrameLawrence Mandarinoprogress
06/25/2024Fenestration air leakageLawrence Mandarinoenergy_progress
06/25/2024Electric vehicle service equipment requirementsLawrence Mandarinoenergy_progress
06/25/2024HVAC-R and service water heating system controlsLawrence Mandarinoenergy_progress
06/25/2024Air barrier - visual inspectionLawrence Mandarinoenergy_progress
06/25/2024Insulation placement and R valuesLawrence Mandarinoenergy_progress
06/25/2024Fenestration and door U-factor and product ratingsLawrence Mandarinoenergy_progress
06/25/2024HVAC-R and service water heating equipmentLawrence Mandarinoenergy_progress
06/25/2024Maintenance informationLawrence Mandarinoenergy_progress
06/25/2024Permanent certificateLawrence Mandarinoenergy_progress
06/25/2024Fenestration areasLawrence Mandarinoenergy_progress
06/25/2024MeteringLawrence Mandarinoenergy_progress
12/12/2023Fire-Resistant Penetrations and JointsLawrence Mandarinospecial
12/12/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationLawrence Mandarinospecial
12/12/2023Energy Code Compliance InspectionsLawrence Mandarinoprogress
Latest 25 of 29.
▾Documents — 68 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/22/2026S00965982-I1Request digital key ↗
08/21/2026S00973563-I1Request digital key ↗
08/21/2026S00956133-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits7
▸BISBPP-5 - Authorization to the Department of Transportation4
12/08/2023540259067Open ↗
12/01/2023540259067Open ↗
11/20/2023540259067Open ↗
Showing 3 of 4 on file for this type
▸BISBPP-16 - Application for waiver of curb alignment and/or sidewalk and curb2
12/01/2023540259067Open ↗
11/20/2023540259067Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
10/06/2023540259067Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00956133-P1Open ↗
08/13/2026S00956133-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00956133-P1Open ↗
08/13/2026S00956133-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00956133-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026S00956133-I1Open ↗
09/01/2026S00956133-I1Open ↗
09/01/2026S00956133-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/21/2026S00956133-I1Open ↗
08/21/2026S00956133-P1Open ↗
08/21/2026S00956133-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026S00956133-I1Open ↗
08/28/2026S00956133-S2Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/06/2023540259067Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S00956133-P1Open ↗
08/13/2026S00956133-I1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026S00956133-P1Open ↗
08/13/2026S00956133-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00956133-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026S00956133-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00956133-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/21/2026S00956133-P1Open ↗
08/21/2026S00956133-S2Open ↗
08/21/2026S00956133-S1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports4
▸BISBPP-9 - Request for Builders Pavement Field Inspection3
12/01/2023540259067Open ↗
11/20/2023540259067Open ↗
10/06/2023540259067Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026S00956133-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff4
12/04/2023540259067Open ↗
12/01/2023540259067Open ↗
11/20/2023540259067Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
12/01/2023540259067Open ↗
11/20/2023540259067Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/06/2023540259067Open ↗
▸Other Documents11
▸BISBPP - SUPPORTING DOCUMENTATION2
11/20/2023540259067Open ↗
10/06/2023540259067Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026S00956133-P1Open ↗
08/13/2026S00956133-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026S00956133-I1Open ↗
08/13/2026S00956133-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/21/2026S00956133-P1Open ↗
08/21/2026S00956133-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00956133-I1Open ↗
08/13/2026S00956133-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026S00956133-I1Open ↗