← Back
Two family frame
525 WEST CASWELL AVENUE
STATEN ISLAND · BIN 5029974
💬 Discuss this project
1997Year Built
2Stories
B2Building Class
R3XZoning
1,620 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,800 sf lot · 0.58 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 21p · 1 filing · 7 docs
Floor 1
Cellar2p · 1 filing · 7 docs
2 jobs · most recent 09/17/2024
General Wiring
FiledStatusContractorScope
09/17/2024Permit IssuedPLAZA ELEC'L CONTR'S. INCGeneral Wiring
07/22/2020CompleteSUNRUN SOLAR ELECTL CORP—
Building Lifecycle
All (9)Filed (2)Permit Issued (1)Signed Off (1)Violation (1)Inspection (2)Special Inspection (2)
04/08/2025
Signed off — Alteration
DIRECT REPLACEMENT OF EXISTING FURNACE AT EXISTING BASEMENT. ORIGINALLY FILED UNDER APPLICATION #500240036
S01094397-I1
03/20/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/12/2024
Special inspection requirement — HVAC-R and service water heating equipment
Ralph Giorgio
12/09/2024
Filed — Alteration
DIRECT REPLACEMENT OF EXISTING FURNACE AT EXISTING BASEMENT. ORIGINALLY FILED UNDER APPLICATION #500240036
S01094397-P1
12/06/2024
Special inspection requirement — HVAC-R and service water heating equipment
Ralph Giorgio
11/22/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/17/2024
Permit issued — Plumbing
S01094397-I1-PL
08/26/2024
Filed — Alteration
DIRECT REPLACEMENT OF EXISTING FURNACE AT EXISTING BASEMENT. ORIGINALLY FILED UNDER APPLICATION #500240036
S01094397-I1
05/20/1997
Violation issued (DOB, closed)
V%*-DOB VIOLATION - DISMISSED
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PERMANENT ENGINEERING P.C.212/09/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLAZA ELEC'L CONTR'S. INCElectrical103/22/2026
SALLEMI, JElectrical103/21/2026
STEEL, URIElectrical103/21/2026
TRISTATE CRANEElectrical103/21/2026
SCARAN PLUMBING INCPlumbing107/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSCARAN PLUMBING INC10/17/2024
BISOTISSUEDSUNRUN INSTALLATION SVC07/20/2020
BISPLISSUEDEAGLE PLUMBING & HEATING OF SI12/23/1997
BIS—ISSUEDOCEANVIEW ESTATES12/02/1997
BIS—ISSUEDM.D.T. EXCAVATION INC10/28/1997
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/20/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/22/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
12/12/2024HVAC-R and service water heating equipmentRalph Giorgioenergy_progress
12/06/2024HVAC-R and service water heating equipmentRalph Giorgioenergy_progress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026S01094397-P1Request digital key ↗
08/20/2026S01094397-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
08/16/2020540179171Open ↗
08/06/2020540179171Open ↗
07/17/2020540179171Open ↗
▸BISWORK PERMIT APPLICATION1
07/20/2020540179171Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026S01094397-P1Open ↗
08/20/2026S01094397-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026S01094397-I1Open ↗
08/28/2026S01094397-P1Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/17/2020540179171Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/17/2020540179171Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/17/2020540179171Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
07/17/2020540179171Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/29/2020540179171Open ↗
07/17/2020540179171Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
08/06/2020540179171Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
12/29/2020540179171Open ↗
▸BISNYCECC ANALYSIS1
07/17/2020540179171Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
07/17/2020540179171Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
12/29/2020540179171Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/17/2020540179171Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/29/2020540179171Open ↗
07/17/2020540179171Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION3
12/29/2020540179171Open ↗
12/29/2020540179171Open ↗
07/17/2020540179171Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/29/2020540179171Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
08/06/2020540179171Open ↗
07/17/2020540179171Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
12/29/2020540179171Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
07/17/2020540179171Open ↗
▸BISADDITIONAL INFORMATION1
08/16/2020540179171Open ↗