← Back
Three families
801 WILLOW ROAD WEST
STATEN ISLAND · BIN 5030347
💬 Discuss this project
1920Year Built
3Stories
C0Building Class
R3XZoning
2,140 sfGross Floor Area
3Units
10 Open Violations ▸FDNY Report ↗
Three families · 3,373 sf lot · 0.63 FAR built · Flood zone X
Locations of Work
Plumbing
Basement1p · 1 filing · 8 docs
2 jobs · most recent 02/14/2023
FiledStatusContractorScope
02/14/2023CompletePLM ELECTRIC LLC2 meters, 2 new_meters
04/30/2020Permit IssuedDELTEX ELECTRICAL CONT. I3 meters, 3 new_meters
Building Lifecycle
All (31)Filed (2)Permit Issued (1)Signed Off (1)Violation (18)Inspection (4)Special Inspection (5)
01/27/2026
Signed off — Alteration
APPLICATION FILED TO INSTALL NEW GAS PIPING, GAS BOILERS AND GAS WATER HEATERS ALL AS PER PLANS FILED HEREWITH.
S01102507-I1
11/26/2025
Violation issued (HPD, open)
I
12/20/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/20/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/11/2024
Filed — Alteration
APPLICATION FILED TO INSTALL NEW GAS PIPING, GAS BOILERS AND GAS WATER HEATERS ALL AS PER PLANS FILED HEREWITH.
S01102507-P1
12/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
PETER NYIAM
12/11/2024
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
12/11/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
FRANKLYN ESTRELLA
12/11/2024
Special inspection requirement — HVAC-R and service water heating equipment
FRANKLYN ESTRELLA
12/11/2024
Special inspection requirement — HVAC-R and service water heating system controls
FRANKLYN ESTRELLA
12/06/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/05/2024
Violation issued (HPD, open)
I
11/27/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/01/2024
Permit issued — Plumbing
S01102507-I1-PL
09/04/2024
Filed — Alteration
APPLICATION FILED TO INSTALL NEW GAS PIPING, GAS BOILERS AND GAS WATER HEATERS ALL AS PER PLANS FILED HEREWITH.
S01102507-I1
11/30/2023
Violation issued (HPD, open)
I
11/21/2022
Violation issued (HPD, open)
I
05/05/2022
Violation issued (HPD, closed)
C
05/05/2022
Violation issued (HPD, open)
C
04/25/2022
Violation issued (HPD, closed)
C
04/25/2022
Violation issued (HPD, closed)
C
04/25/2022
Violation issued (HPD, open)
C
04/14/2022
Violation issued (ECB, closed)
Construction
03/18/2022
Violation issued (HPD, open)
I
04/22/2021
Violation issued (HPD, open)
I
03/16/2020
Violation issued (HPD, closed)
C
03/16/2020
Violation issued (HPD, closed)
C
03/16/2020
Violation issued (HPD, closed)
C
03/16/2020
Violation issued (HPD, closed)
C
11/08/2019
Violation issued (HPD, open)
I
01/11/2018
Violation issued (HPD, open)
I
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PETER NYIAM212/11/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FRANKLYN ESTRELLA ARCHITECT PLLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DELTEX ELECTRICAL CONT. IElectrical103/22/2026
PLM ELECTRIC LLCElectrical103/22/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519112/11/2024
PIBIEN ENGINEERS9656109/04/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP10/01/2024
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
12/20/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/20/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/06/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/27/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
12/11/2024Fire-Resistant Penetrations and JointsPETER NYIAMspecial
12/11/2024Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
12/11/2024HVAC-R and service water piping design and insulationFRANKLYN ESTRELLAenergy_progress
12/11/2024HVAC-R and service water heating equipmentFRANKLYN ESTRELLAenergy_progress
12/11/2024HVAC-R and service water heating system controlsFRANKLYN ESTRELLAenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026S01102507-P1Request digital key ↗
08/21/2026S01102507-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026S01102507-P1Open ↗
08/21/2026S01102507-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026S01102507-I1Open ↗
08/27/2026S01102507-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026S01102507-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026S01102507-P1Open ↗
08/21/2026S01102507-I1Open ↗