← Back
One story - permanent living quarter
16 ALBERTA AVENUE
STATEN ISLAND · BIN 5041824
💬 Discuss this project
1950Year Built
1Stories
A2Building Class
R3AZoning
956 sfGross Floor Area
1Units
0 Open Violations
One story - permanent living quarter · 7,500 sf lot · 0.13 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof1p · 1 filing · 11 docs
Floor 21p · 1 filing · 11 docs
Floor 1
Cellar1p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGERS CALVANICO GROUP PLLC311/30/2023
GRACE ENGINEERING PLLC.108/25/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARCHITECTUAL CONCEPT203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GRACE ENGINEERING PLLC.2176108/25/2021
Building Lifecycle
All (32)Filed (4)Violation (1)Objection (3)Special Inspection (24)
11/30/2023
Filed — Alteration CO
Proposed Vertical extension to existing (1) story residence. add new second floor & roof. no change in use or occupancy, to remain one family. change in bldg height, new c of o required.
S00921774-S1
11/20/2023
Objection resolved — Addressed
11/17/2023
Objection raised — Scope
10/23/2023
Filed — Alteration CO
Proposed Vertical extension to existing (1) story residence. add new second floor & roof. no change in use or occupancy, to remain one family. change in bldg height, new c of o required.
S00921774-I1
10/18/2023
Filed — Alteration
CONSTRUCTION FENCE
S00869337-I1
08/18/2023
Special inspection requirement — Chimneys and vents
08/18/2023
Special inspection requirement — Concrete - Cast-In-Place
08/18/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/18/2023
Special inspection requirement — Structural Steel - Details
08/18/2023
Special inspection requirement — Structural Steel - Welding
08/18/2023
Special inspection requirement — Subgrade Inspections
08/18/2023
Special inspection requirement — Final
08/18/2023
Special inspection requirement — Footing and Foundation
08/18/2023
Special inspection requirement — Energy Code Compliance Inspections
08/18/2023
Special inspection requirement — Structural Wood Frame
08/18/2023
Special inspection requirement — Air barrier - visual inspection
08/18/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
08/18/2023
Special inspection requirement — HVAC-R and service water heating system controls
08/18/2023
Special inspection requirement — Duct leakage testing, insulation and design
08/18/2023
Special inspection requirement — Fenestration areas
08/18/2023
Special inspection requirement — Fenestration air leakage
08/18/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
08/18/2023
Special inspection requirement — Maintenance information
08/18/2023
Special inspection requirement — Insulation placement and R values
08/18/2023
Special inspection requirement — Metering
08/18/2023
Special inspection requirement — HVAC-R and service water heating equipment
08/18/2023
Special inspection requirement — Permanent certificate
08/18/2023
Special inspection requirement — Ventilation and air distribution system
08/18/2023
Special inspection requirement — Interior lighting power
04/27/2022
Objection raised — Scope
08/25/2021
Filed — Alteration CO
Addition of second floor in existing one family house.
S00582022-I1
09/14/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Nothing on file for this building.
1 project · most recent 08/25/2021
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/25/2021——Air Conditioning Systems, Ventilation Systems
Cooling
Goodman ASPT39C14 36,000 BTU · Furnace ×1
Ventilation
Greenheck SP-C50-QD 50 CFM · Exhaust Fan ×2
1 project · most recent 11/30/2023
Gas Water/Sanitary
FiledStatusContractorScope
11/30/2023——Gas, Water/Sanitary
1 project · most recent 08/28/2025
FiledStatusContractorScope
08/28/2025CompleteSTATEN ISLAND ELEC CONT.1 meters, 1 new_meters
2 projects · most recent 11/30/2023
Wood Steel
FiledStatusContractorScope
11/30/2023——Steel, Wood
08/25/2021——Wood
1 project · most recent 10/18/2023
Fence
FiledStatusContractorScope
10/18/2023——Fence
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
08/18/2023Chimneys and vents—special
08/18/2023Concrete - Cast-In-Place—special
08/18/2023Structural Stability – Alterations of existing buildings—special
08/18/2023Structural Steel - Details—special
08/18/2023Structural Steel - Welding—special
08/18/2023Subgrade Inspections—special
08/18/2023Final—progress
08/18/2023Footing and Foundation—progress
08/18/2023Energy Code Compliance Inspections—progress
08/18/2023Structural Wood Frame—progress
08/18/2023Air barrier - visual inspection—energy_progress
08/18/2023Fenestration and door U-factor and product ratings—energy_progress
08/18/2023HVAC-R and service water heating system controls—energy_progress
08/18/2023Duct leakage testing, insulation and design—energy_progress
08/18/2023Fenestration areas—energy_progress
08/18/2023Fenestration air leakage—energy_progress
08/18/2023HVAC-R and service water piping design and insulation—energy_progress
08/18/2023Maintenance information—energy_progress
08/18/2023Insulation placement and R values—energy_progress
08/18/2023Metering—energy_progress
08/18/2023HVAC-R and service water heating equipment—energy_progress
08/18/2023Permanent certificate—energy_progress
08/18/2023Ventilation and air distribution system—energy_progress
08/18/2023Interior lighting power—energy_progress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026S00869337-I1Request digital key ↗
08/22/2026S00921774-S1Request digital key ↗
08/22/2026S00921774-I1Request digital key ↗
▸Applications & Permits6
▸BISBPP-5 - Authorization to the Department of Transportation4
09/08/2023540256097Open ↗
09/07/2023540256097Open ↗
08/25/2023540256097Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
08/21/2023540256097Open ↗
01/15/2020520397507Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S00921774-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026S00921774-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026S00869337-I1Open ↗
08/13/2026S00921774-I1Open ↗
08/13/2026S00921774-S1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
08/21/2023540256097Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/15/2020520397507Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE SUPPORTING DOCUMENT1
08/24/2023540256097Open ↗
▸BISSTREET TREE CHECKLIST1
09/07/2023540256097Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026S00921774-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/15/2020520397507Open ↗
▸Inspections & Test Reports2
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
09/08/2023540256097Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/21/2023540256097Open ↗
▸Approvals, Objections & Sign-offs4
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff3
09/08/2023540256097Open ↗
09/08/2023540256097Open ↗
09/08/2023540256097Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
01/15/2020520397507Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
01/15/2020520397507Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET1
01/15/2020520397507Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/21/2023540256097Open ↗
▸BISADDITIONAL INFORMATION1
08/25/2023540256097Open ↗
▸Other Documents7
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
09/07/2023540256097Open ↗
▸BISBPP: GRADE STUDY1
09/07/2023540256097Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
08/21/2023540256097Open ↗
▸DOB NOWPlot Diagram1
08/13/2026S00921774-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026S00921774-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026S00921774-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00921774-I1Open ↗