← Back
Single or multiple dwelling with stores or offices
1252 BAY STREET
STATEN ISLAND · BIN 5042880
💬 Discuss this project
1931Year Built
3Stories
S9Building Class
R3AZoning
2,952 sfGross Floor Area
6Units
Rent Stabilized3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: TJS BAY STREET LLC · 5,000 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
MechanicalFire Protection
Permit Issued — active, not yet Signed-off
Floor 3Under Construction1p · 1 filing · 11 docs
Floor 2Under Construction1p · 1 filing · 11 docs
Floor 1Under Construction1p · 1 filing · 11 docs
CellarUnder Construction3p · 1 filing · 11 docs
2 jobs · most recent 07/22/2026
Ventilation Systems Heating and Air Conditioning Systems Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/22/2026Permit IssuedREDLINE CONSTR & MGMT LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Goodman AMST48DU14 48,000 BTU · Ahu ×1
GSXH504810 48,000 BTU · Condensing Unit ×1
11/14/2025Signed-offLXC CONSTRUCTION INCAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric Wall Mounted Mitsubishi Mini Split Single 79,400 BTU ×2
Ventilation
Greenheck MUA CENTRIFUGAL INLINE FAN 800 CFM · Exhaust Fan ×1
1 job · most recent 11/14/2025
Water/Sanitary
FiledStatusContractorScope
11/14/2025Signed-offDYNAMIC PLBG & SPRKLR CORWater/Sanitary
1 job · most recent 07/22/2026
Fence
FiledStatusContractorScope
07/22/2026Permit IssuedREDLINE CONSTR & MGMT LLCFence
Building Lifecycle
All (49)Filed (6)Permit Issued (5)Violation (18)Inspection (2)Special Inspection (18)
08/17/2026
Permit issued — Mechanical Systems
S01433335-I1-GC-CX
07/28/2026
Permit issued — Construction Fence
S01433335-S2-FN
07/22/2026
Filed — Alteration
Application is filed for temporary construction fence in conjunction with separately filed alteration application.
S01433335-S2
07/22/2026
Filed — Alteration
Application is filed for temporary construction fence in conjunction with separately filed alteration application.
S01433335-S1
07/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
07/22/2026
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
07/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
07/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
07/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
07/21/2026
Filed — Alteration
Application is filed for temporary construction fence in conjunction with separately filed alteration application.
S01433335-I1
03/27/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/26/2026
Violation issued (FDNY_NOV, closed)
03/26/2026
Violation issued (FDNY_NOV, closed)
12/22/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/11/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/26/2025
Permit issued — Mechanical Systems
S01307216-S1-MS
11/25/2025
Permit issued — Plumbing
S01307216-S2-PL
11/21/2025
Permit issued — General Construction
S01307216-I1-GC
11/14/2025
Filed — Alteration
Proposed mechanical system works as per plan. No change of use, egress and occupancy.
S01307216-S2
11/13/2025
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
11/13/2025
Special inspection requirement — Tenant Protection Plan Compliance
XIUCHENG LI
11/10/2025
Filed — Alteration
Proposed mechanical system works as per plan. No change of use, egress and occupancy.
S01307216-S1
11/05/2025
Special inspection requirement — Lighting controls
XIUCHENG LI
11/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
11/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
11/05/2025
Special inspection requirement — Duct leakage testing, insulation and design
XIUCHENG LI
11/05/2025
Special inspection requirement — Maintenance information
XIUCHENG LI
10/28/2025
Special inspection requirement — Tenant Protection Plan Compliance
XIUCHENG LI
10/27/2025
Filed — Alteration
Proposed mechanical system works as per plan. No change of use, egress and occupancy.
S01307216-I1
10/24/2025
Special inspection requirement — Tenant Protection Plan Compliance
XIUCHENG LI
10/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
10/22/2025
Special inspection requirement — Mechanical Systems
XIUCHENG LI
10/22/2025
Special inspection requirement — Final
XIUCHENG LI
10/22/2025
Special inspection requirement — Final
XIUCHENG LI
12/05/2024
Violation issued (HPD, closed)
I
11/30/2023
Violation issued (HPD, closed)
I
03/18/2022
Violation issued (HPD, closed)
I
11/08/2019
Violation issued (HPD, closed)
I
10/06/2003
Violation issued (HPD, closed)
B
10/06/2003
Violation issued (HPD, closed)
B
10/06/2003
Violation issued (HPD, closed)
B
10/06/2003
Violation issued (HPD, closed)
B
10/06/2003
Violation issued (HPD, closed)
B
10/06/2003
Violation issued (HPD, closed)
B
11/20/2000
Violation issued (FDNY_NOV, closed)
10/05/2000
Violation issued (ECB, closed)
Construction
08/14/1990
Violation issued (ECB, closed)
Construction
03/12/1990
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
03/12/1990
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
REDLINE CONSTRUCTION MANAGEMENT L208/18/2026
TJS BAY STREET LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THINK DESIGN ARCHITECTURE307/22/2026
CHK PLUS INC311/14/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BAYSIDE ENGINEERING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LXC CONSTRUCTION INCGeneral Contractor404/09/2026
REDLINE CONSTR & MGMT LLCGeneral Contractor208/18/2026
DYNAMIC PLBG & SPRKLR CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738207/22/2026
SD TESTING & INSPECTION S7010311/14/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedREDLINE CONSTR & MGMT LLC08/17/2026
DOB NOWConstruction FencePermit IssuedREDLINE CONSTR & MGMT LLC07/28/2026
DOB NOWMechanical SystemsSigned-offLXC CONSTRUCTION INC11/26/2025
DOB NOWPlumbingSigned-offCITYWIDE PLBG HTG & SPKLS11/25/2025
DOB NOWGeneral ConstructionSigned-offLXC CONSTRUCTION INC11/21/2025
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
12/22/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/11/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
07/22/2026Fire-Resistant Penetrations and Jointsanthony santorospecial
07/22/2026Energy Code Compliance Inspectionsanthony santoroprogress
07/22/2026HVAC-R and service water heating equipmentanthony santoroenergy_progress
07/22/2026HVAC-R and service water heating system controlsanthony santoroenergy_progress
07/22/2026HVAC-R and service water piping design and insulationanthony santoroenergy_progress
11/13/2025Energy Code Compliance InspectionsXIUCHENG LIprogress
11/13/2025Tenant Protection Plan ComplianceXIUCHENG LIspecial
11/05/2025Lighting controlsXIUCHENG LIenergy_progress
11/05/2025HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
11/05/2025HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
11/05/2025Duct leakage testing, insulation and designXIUCHENG LIenergy_progress
11/05/2025Maintenance informationXIUCHENG LIenergy_progress
10/28/2025Tenant Protection Plan ComplianceXIUCHENG LIspecial
10/24/2025Tenant Protection Plan ComplianceXIUCHENG LIspecial
10/24/2025Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
10/22/2025Mechanical SystemsXIUCHENG LIspecial
10/22/2025FinalXIUCHENG LIprogress
10/22/2025FinalXIUCHENG LIprogress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/17/2026S01307216-I1Request digital key ↗
08/17/2026S01307216-S2Request digital key ↗
08/17/2026S01307216-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/17/2026S01307216-S1Open ↗
08/17/2026S01307216-I1Open ↗
08/17/2026S01307216-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026S01307216-S1Open ↗
09/23/2026S01307216-S1Open ↗
09/21/2026S01433335-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026S01307216-S1Open ↗
09/21/2026S01433335-S1Open ↗
08/27/2026S01307216-S2Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/16/2026S01433335-I1Open ↗
08/16/2026S01433335-S1Open ↗