| Owner | Filings | Most Recent |
|---|---|---|
| H M BUILD AND UPLIFT CORP | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| AVID DESIGNS, INC | 5 | 08/28/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| HM BUILD AND UPLIFT CORP | General Contractor | 2 | 04/09/2026 |
| TOP BUILD CONTRACTORS INC | General Contractor | 2 | 07/08/2026 |
| AMERICAN STANDARD P&H CORORP. | Plumbing | 1 | 07/08/2026 |
| R&M PIPING & HTG INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| AVID DESIGNS, INC. | 453 | 4 | 08/28/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | AMERICAN STANDARD P&H CORORP. | 05/06/2026 |
| DOB NOW | Construction Fence | Permit Issued | TOP BUILD CONTRACTORS INC | 05/06/2026 |
| DOB NOW | General Construction | Permit Issued | TOP BUILD CONTRACTORS INC | 05/04/2026 |
| DOB NOW | Construction Fence | Permit Issued | HM BUILD UPLIFT | 10/15/2025 |
| DOB NOW | Plumbing | Permit Issued | R&M PIPING & HTG INC | 08/11/2025 |
| DOB NOW | Construction Fence | Permit Issued | HM BUILD UPLIFT | 10/09/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/28/2026 | Permit Issued | TOP BUILD CONTRACTORS INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool York YC442E2S11 42,000 BTU · Condensing Unit ×3 Y91E080B12SMPS1A (EFFICIENCY IN % AFUE, LABELED COP DUE TO SYSTEM LIMITATIONS) 75,000 BTU · Ahu ×2 Y91E100C20SMPS1A (EFFICIENCY IN % AFUE, LABELED COP DUE TO SYSTEM LIMITATIONS) 95,000 BTU · Ahu ×1 Weil-Mclain CGa-5 (NOTE: UNIT IS 84% AFUE, LISTED AS COP DUE TO DOB NOW SYSTEM LIMITATIONS) 98,000 BTU · Boiler ×4 Mitsubishi Electric MSZ-WR09NA (NOTE: EFFICIENCY MEASURED IN SEER2, LABELED AS SEER DUE TO DOB NOW SYSTEM LIMITATIONS) 9,000 BTU · Split System ×7 MSZ-WR18NA (NOTE: EFFICIENCY MEASURED IN SEER2, LABELED AS SEER DUE TO DOB NOW SYSTEM LIMITATIONS) 17,200 BTU · Fan Coil Indoor ×5 MUZ-WR09NA-U2 (NOTE: EFFICIENCY MEASURED IN SEER2, LABELED AS SEER DUE TO DOB NOW SYSTEM LIMITATIONS) 9,000 BTU · Heat Pump Outdoor ×2 MUZ-WR18NA-U2 (NOTE: EFFICIENCY MEASURED IN SEER2, LABELED AS SEER DUE TO DOB NOW SYSTEM LIMITATIONS) 17,200 BTU · Heat Pump Outdoor ×2 Ventilation Fantech SER130 (NOTE: EFFICIENCY IS 1.275 CFM/WATT, NOT COP, LISTED AS COP DUE TO DOB NOW SYSTEM LIMITATIONS) 130 CFM · Erv ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/15/2026 | Permit Issued | J Y ELECTRIC INC | General Wiring |
| 12/13/2024 | Permit Issued | JOHN MICHAEL AND SONS ELE | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/28/2026 | Permit Issued | TOP BUILD CONTRACTORS INC | Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/15/2026 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 05/15/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 05/15/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/13/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 09/26/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 07/28/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 06/04/2025 | Fail-Final Fence Withdrawal | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/27/2026 | Insulation placement and R values | Jeffrey Geary | energy_progress |
| 08/27/2026 | Concrete - Cast-In-Place | Jeffrey Geary | special |
| 08/27/2026 | Fire-Resistant Penetrations and Joints | Jeffrey Geary | special |
| 08/27/2026 | Mechanical Systems | Jeffrey Geary | special |
| 08/27/2026 | Structural Stability – Alterations of existing buildings | Jeffrey Geary | special |
| 08/27/2026 | Subgrade Inspections | Jeffrey Geary | special |
| 08/27/2026 | Energy Code Compliance Inspections | Jeffrey Geary | progress |
| 08/27/2026 | Final | Jeffrey Geary | progress |
| 08/27/2026 | Fire-Resistance Rated Construction | Jeffrey Geary | progress |
| 08/27/2026 | Footing and Foundation | Jeffrey Geary | progress |
| 08/27/2026 | Structural Wood Frame | Jeffrey Geary | progress |
| 08/27/2026 | Fenestration air leakage | Jeffrey Geary | energy_progress |
| 08/27/2026 | Electric vehicle service equipment requirements | Jeffrey Geary | energy_progress |
| 08/27/2026 | Fenestration and door U-factor and product ratings | Jeffrey Geary | energy_progress |
| 08/27/2026 | HVAC-R and service water heating equipment | Jeffrey Geary | energy_progress |
| 08/27/2026 | Fenestration areas | Jeffrey Geary | energy_progress |
| 08/27/2026 | Air barrier — testing | Jeffrey Geary | energy_progress |
| 08/27/2026 | Ventilation and air distribution system | Jeffrey Geary | energy_progress |
| 08/27/2026 | HVAC-R and service water heating system controls | Jeffrey Geary | energy_progress |
| 08/27/2026 | Metering | Jeffrey Geary | energy_progress |
| 08/27/2026 | Air barrier - visual inspection | Jeffrey Geary | energy_progress |
| 08/27/2026 | Interior lighting power | Jeffrey Geary | energy_progress |
| 08/27/2026 | HVAC-R and service water piping design and insulation | Jeffrey Geary | energy_progress |
| 08/27/2026 | Permanent certificate | Jeffrey Geary | energy_progress |
| 09/20/2024 | HVAC-R and service water heating equipment | Jeffrey Geary | energy_progress |