← Back
Two stories - detached, small or mid-size
3 CASCADE STREET
STATEN ISLAND · BIN 5051335
💬 Discuss this project
1935Year Built
2Stories
A1Building Class
R3XZoning
1,192 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 3,080 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Roof1p · 1 filing · 16 docs
Floor 22p · 1 filing · 10 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MZM CONSTRUCTION SERVICES103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC201/17/2025
ARC CONSULTING ENGINEERS506/20/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JRK CREATIVE1003/21/2026
SUNRUN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MZM CONSTRUCTION SERVICEGeneral Contractor407/08/2026
KWONG MING ELECTRIC INCElectrical103/22/2026
SUNRUN INSTALLATION SVCGeneral Contractor107/08/2026
PIPESTYLISTS, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272201/17/2025
ARC CONSULTING ENGINEERS,4083506/20/2024
Building Lifecycle
All (33)Filed (7)Permit Issued (4)Signed Off (3)Violation (2)Inspection (5)Special Inspection (12)
04/04/2025
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01140816-I1
01/17/2025
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01140816-P1
12/03/2024
Permit issued — Solar
S01140816-I1-SL
11/20/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01140816-I1
10/08/2024
Signed off — Alteration
INTERIOR RENOVATION ON CELLAR, 1ST AND 2ND FLOOR FOR EXISTING ONE FAMILY DWELLING. PLUMBING WORK FILE SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00946093-I1
10/07/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/07/2024
Signed off — Alteration
FILE PLUMBING WORK TYPE IN CONJUNCTION WITH S00946093.
S00947244-I1
08/06/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/21/2024
Special inspection requirement — Interior lighting power
JAN PEREZ
06/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
06/21/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JAN PEREZ
06/21/2024
Special inspection requirement — Fire-Resistance Rated Construction
JAN PEREZ
06/21/2024
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
06/21/2024
Special inspection requirement — Fenestration air leakage
JAN PEREZ
06/21/2024
Special inspection requirement — Concrete - Cast-In-Place
JAN PEREZ
06/20/2024
Filed — Alteration
INTERIOR RENOVATION ON CELLAR, 1ST AND 2ND FLOOR FOR EXISTING ONE FAMILY DWELLING. PLUMBING WORK FILE SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00946093-P2
05/17/2024
Violation issued (ECB, closed)
Construction
04/19/2024
Permit issued — General Construction
S00946093-I1-GC
02/22/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/13/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/01/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/29/2024
Special inspection requirement — HVAC-R and service water heating system controls
JAN PEREZ
01/29/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
JAN PEREZ
01/29/2024
Special inspection requirement — Maintenance information
JAN PEREZ
01/29/2024
Special inspection requirement — HVAC-R and service water heating equipment
JAN PEREZ
01/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
01/26/2024
Filed — Alteration
FILE PLUMBING WORK TYPE IN CONJUNCTION WITH S00946093.
S00947244-P1
11/18/2023
Filed — Alteration
INTERIOR RENOVATION ON CELLAR, 1ST AND 2ND FLOOR FOR EXISTING ONE FAMILY DWELLING. PLUMBING WORK FILE SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00946093-P1
11/09/2023
Permit issued — General Construction
S00946093-I1-GC
10/30/2023
Permit issued — Plumbing
S00947244-I1-PL
10/19/2023
Filed — Alteration
INTERIOR RENOVATION ON CELLAR, 1ST AND 2ND FLOOR FOR EXISTING ONE FAMILY DWELLING. PLUMBING WORK FILE SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00946093-I1
10/19/2023
Filed — Alteration
FILE PLUMBING WORK TYPE IN CONJUNCTION WITH S00946093.
S00947244-I1
09/07/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC12/03/2024
DOB NOWGeneral ConstructionSigned-offMZM CONSTRUCTION SERVICE04/19/2024
DOB NOWGeneral ConstructionSigned-offMZM CONSTRUCTION SERVICE11/09/2023
DOB NOWPlumbingSigned-offT & T PLUMBING INC10/30/2023
3 projects · most recent 11/20/2024
General Wiring
FiledStatusContractorScope
11/20/2024CompleteSUNRUN SOLAR ELECTL CORP—
06/12/2024CompleteKWONG MING ELECTRIC INC1 meters, 1 new_meters
10/27/2023CompleteKWONG MING ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/07/2024Pass-Final General Construction Non-Directive 14PassView ↗
08/06/2024Fail-Final General Construction Non-Directive 14FailView ↗
02/22/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/13/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/01/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
06/21/2024Interior lighting powerJAN PEREZenergy_progress
06/21/2024Fire-Resistant Penetrations and JointsJAN PEREZspecial
06/21/2024Structural Stability – Alterations of existing buildingsJAN PEREZspecial
06/21/2024Fire-Resistance Rated ConstructionJAN PEREZprogress
06/21/2024Energy Code Compliance InspectionsJAN PEREZprogress
06/21/2024Fenestration air leakageJAN PEREZenergy_progress
06/21/2024Concrete - Cast-In-PlaceJAN PEREZspecial
01/29/2024HVAC-R and service water heating system controlsJAN PEREZenergy_progress
01/29/2024HVAC-R and service water piping design and insulationJAN PEREZenergy_progress
01/29/2024Maintenance informationJAN PEREZenergy_progress
01/29/2024HVAC-R and service water heating equipmentJAN PEREZenergy_progress
01/29/2024Fire-Resistant Penetrations and JointsJAN PEREZspecial
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/22/2026S00947244-I1Request digital key ↗
08/22/2026S00947244-P1Request digital key ↗
08/22/2026S00946093-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/22/2026S00947244-I1Open ↗
08/13/2026S00947244-P1Open ↗
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026S00947244-I1Open ↗
08/22/2026S00946093-I1Open ↗
08/22/2026S00946093-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/25/2026S00946093-I1Open ↗
08/25/2026S00946093-I1Open ↗
08/25/2026S00946093-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/25/2026S00946093-I1Open ↗
08/25/2026S00946093-I1Open ↗
08/25/2026S00946093-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/22/2026S00947244-I1Open ↗
08/22/2026S00946093-I1Open ↗
08/22/2026S00946093-P1Open ↗
Showing 3 of 7 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01140816-I1Open ↗