← Back
Two stories - detached, small or mid-size
73 COLONY AVENUE
STATEN ISLAND · BIN 5054500
💬 Discuss this project
1975Year Built
2Stories
A1Building Class
R3-1Zoning
1,120 sfGross Floor Area
1Units
4 Open Violations 1 unresolved · 3 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 17,640 sf lot · 0.06 FAR built · Flood zone VE
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THE OWNER OF403/22/2026
OWNER OF PROPERTY103/22/2026
OWNER OF 73 COLONY AVENUE203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADNAN ENGINEERING, P.C.105/26/2023
FRED W. TORRICO ARCHITECT105/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FRED W. TORRICO, ARCHITECT203/21/2026
Building Lifecycle
All (43)Filed (2)Violation (8)Objection (19)Special Inspection (14)
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Structural
02/21/2025
Objection raised — Scope
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Fire_Protection
02/21/2025
Objection raised — Scope
08/29/2023
Objection raised — Zoning
08/29/2023
Objection raised — Zoning
08/26/2023
Objection resolved — Addressed
08/26/2023
Objection resolved — Addressed
08/26/2023
Objection resolved — Addressed
08/01/2023
Objection raised — Zoning
08/01/2023
Objection raised — Zoning
08/01/2023
Objection raised — Scope
08/01/2023
Objection raised — Inspections
08/01/2023
Objection raised — Zoning
05/26/2023
Filed — Alteration
S00869709-I1
05/25/2023
Filed — Alteration CO
S00858270-I1
05/03/2023
Special inspection requirement — Footing and Foundation
05/03/2023
Special inspection requirement — Helical Piles Foundation (BB # 2014-020)
05/03/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/03/2023
Special inspection requirement — Structural Steel - Details
05/03/2023
Special inspection requirement — Structural Steel - High Strength Bolting
05/03/2023
Special inspection requirement — Structural Steel - Welding
05/03/2023
Special inspection requirement — Final
04/11/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
04/11/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/11/2023
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
04/11/2023
Special inspection requirement — Tenant Protection Plan Compliance
04/11/2023
Special inspection requirement — Lowest Floor Elevation
04/11/2023
Special inspection requirement — Energy Code Compliance Inspections
04/11/2023
Special inspection requirement — Fire-Resistance Rated Construction
03/24/2023
Violation issued (ECB, open)
Construction
10/26/2022
Violation issued (ECB, closed)
Construction
04/11/2022
Violation issued (ECB, closed)
Construction
02/28/2022
Violation issued (ECB, closed)
Construction
03/03/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/05/2021
Violation issued (ECB, open)
Construction
12/09/2020
Violation issued (ECB, open)
Construction
12/09/2020
Violation issued (ECB, closed)
Construction
Nothing on file for this building.
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
05/03/2023Footing and Foundation—progress
05/03/2023Helical Piles Foundation (BB # 2014-020)—special
05/03/2023Structural Stability – Alterations of existing buildings—special
05/03/2023Structural Steel - Details—special
05/03/2023Structural Steel - High Strength Bolting—special
05/03/2023Structural Steel - Welding—special
05/03/2023Final—progress
04/11/2023Exterior Insulation and Finish Systems (EIFS)—special
04/11/2023Fire-Resistant Penetrations and Joints—special
04/11/2023Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)—special
04/11/2023Tenant Protection Plan Compliance—special
04/11/2023Lowest Floor Elevation—progress
04/11/2023Energy Code Compliance Inspections—progress
04/11/2023Fire-Resistance Rated Construction—progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026S00869709-I1Request digital key ↗
08/14/2026S00858270-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S00858270-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026S00858270-I1Open ↗
08/13/2026S00869709-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026S00858270-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026S00858270-I1Open ↗
08/13/2026S00869709-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/13/2026S00858270-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026S00858270-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00858270-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026S00858270-I1Open ↗