← Back
Two family frame
373 ROSE AVENUE
STATEN ISLAND · BIN 5057614
💬 Discuss this project
1950Year Built
1.5Stories
B2Building Class
R3XZoning
—Gross Floor Area
2Units
Two family frame · 0.27 FAR built · Flood zone X
Locations of Work
MechanicalGeneral
Roof1p · 1 filing · 19 docs
Floor 21p · 1 filing · 19 docs
Floor 1
Cellar1p · 1 filing · 19 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AVID DESIGNS, INC203/31/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AVID DESIGNS, INC.453203/31/2026
Building Lifecycle
All (14)Filed (2)Objection (1)Special Inspection (11)
05/21/2026
Objection raised — Scope
03/31/2026
Filed — Alteration CO
HEREWITH FILING FOR THE ASSOCIATED MECHANICAL WORK FOR THE RENOVATION, HORIZONTAL AND VERTICAL ENLARGEMENT OF AN EXISTING TWO-FAMILY DWELLING. NO OTHER WORK PROPOSED UNDER THIS APPLICATION.
S01359939-I1
03/31/2026
Filed — Alteration CO
HEREWITH FILING FOR THE ASSOCIATED MECHANICAL WORK FOR THE RENOVATION, HORIZONTAL AND VERTICAL ENLARGEMENT OF AN EXISTING TWO-FAMILY DWELLING. NO OTHER WORK PROPOSED UNDER THIS APPLICATION.
S01359939-S1
03/31/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
03/31/2026
Special inspection requirement — Mechanical Systems
Jeffrey Geary
03/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Geary
03/31/2026
Special inspection requirement — Final
Jeffrey Geary
03/31/2026
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Geary
03/31/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Geary
03/31/2026
Special inspection requirement — HVAC-R and service water heating equipment
Jeffrey Geary
03/31/2026
Special inspection requirement — HVAC-R and service water heating system controls
Jeffrey Geary
03/31/2026
Special inspection requirement — Duct leakage testing, insulation and design
Jeffrey Geary
03/31/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Jeffrey Geary
03/31/2026
Special inspection requirement — Ventilation and air distribution system
Jeffrey Geary
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDRICHMOND PLBG & HEATING INC08/30/2006
BISPLISSUEDEARLY PLBG & HTG INC08/28/2002
BIS—ISSUEDN/A02/01/2002
1 project · most recent 03/31/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/31/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Trane 4TTV0X60A1000A (EFFICIENCY IN "SEER2", LABELED "SEER" DUE TO DOB NOW SYSTEM LIMITATIONS) 60,000 BTU · Condensing Unit ×2
TUHMD120ACV5VA (EFFICIENCY IS 95% "AFUE", LABELED "COP" DUE TO DOB NOW SYSTEM LIMITATIONS) 54,000 BTU · Furnace ×2
Ventilation
Solar & Palau TRe300 (EFFICIENCY MEASURED IN "CFM/WATT" PER R403.6.1, LABELED "COP" DUE TO DOB NOW SYSTEM LIMITATIONS) 288 CFM · Erv ×2
1 project · most recent 03/31/2026
Wood
FiledStatusContractorScope
03/31/2026——Wood
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
03/31/2026Structural Stability – Alterations of existing buildings—special
03/31/2026Mechanical SystemsJeffrey Gearyspecial
03/31/2026Fire-Resistant Penetrations and JointsJeffrey Gearyspecial
03/31/2026FinalJeffrey Gearyprogress
03/31/2026Energy Code Compliance InspectionsJeffrey Gearyprogress
03/31/2026Fire-Resistance Rated ConstructionJeffrey Gearyprogress
03/31/2026HVAC-R and service water heating equipmentJeffrey Gearyenergy_progress
03/31/2026HVAC-R and service water heating system controlsJeffrey Gearyenergy_progress
03/31/2026Duct leakage testing, insulation and designJeffrey Gearyenergy_progress
03/31/2026HVAC-R and service water piping design and insulationJeffrey Gearyenergy_progress
03/31/2026Ventilation and air distribution systemJeffrey Gearyenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026S01359939-I1Request digital key ↗
08/17/2026S01359939-S1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026S01359939-S1Open ↗
09/01/2026S01359939-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026S01359939-S1Open ↗
08/17/2026S01359939-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026S01359939-S1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/17/2026S01359939-I1Open ↗
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026S01359939-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026S01359939-I1Open ↗