← Back
Two stories - detached, small or mid-size
630 DRUMGOOLE ROAD EAST
STATEN ISLAND · Annadale-Huguenot-Prince's Bay-Woodrow · BIN 5080157
💬 Discuss this project
1960Year Built
2Stories
A1Building Class
R3AZoning
2,460 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 8,000 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
624 DRUMGOOLE RD EAST1007/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TERRA PRETA ARCHITECTS306/20/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DESIGN CONCEPTS303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
V & I CONSTRUCTION INCGeneral Contractor107/08/2026
ROM PIPING & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738101/04/2024
Building Lifecycle
All (12)Filed (3)Permit Issued (2)Inspection (1)Objection (4)Special Inspection (2)
09/04/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/02/2024
Permit issued — Plumbing
S00984125-S1-PL
06/20/2024
Filed — Alteration
new gas piping to gas generator located in open space
S00984125-P1
05/30/2024
Objection raised — Other
05/30/2024
Objection resolved — Addressed
05/20/2024
Filed — Alteration
new gas piping to gas generator located in open space
S00984125-S1
02/13/2024
Permit issued — Mechanical Systems
S00984125-I1-MS
02/01/2024
Objection resolved — Addressed
01/10/2024
Objection raised — Other
01/04/2024
Filed — Alteration
new gas piping to gas generator located in open space
S00984125-I1
01/02/2024
Special inspection requirement — Mechanical Systems
anthony santoro
01/02/2024
Special inspection requirement — Final
George Turner
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedROM PIPING & HTG INC08/02/2024
DOB NOWMechanical SystemsPermit IssuedULTIMATE 1 CONSTR INC02/13/2024
BISOTISSUEDARE NEW YORK INC08/05/2013
BIS—ISSUEDV & I CONSTRUCTION INC07/30/2007
1 project · most recent 06/20/2024
Generators
FiledStatusContractorScopeMake / Model / Capacity
06/20/2024Permit IssuedV & I CONSTRUCTION INCGenerators
Generators
Generac G007210-1 24,000 kW · Generator ×1
1 project · most recent 06/20/2024
Gas
FiledStatusContractorScope
06/20/2024Permit IssuedROM PIPING & HTG INCGas
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
09/04/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
01/02/2024Mechanical Systemsanthony santorospecial
01/02/2024FinalGeorge Turnerprogress
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026S00984125-S1Request digital key ↗
08/21/2026S00984125-P1Request digital key ↗
08/21/2026S00984125-I1Request digital key ↗
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION5
10/24/2024500799674Open ↗
04/24/2024500799674Open ↗
03/19/2024500799674Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
09/13/2024500799674Open ↗
▸BISWORK PERMIT APPLICATION1
08/09/2013520134300Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISVERIFY TAX LOT1
11/18/2024500799674Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026S00984125-S1Open ↗
08/13/2026S00984125-I1Open ↗
08/13/2026S00984125-P1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION2
01/29/2014520134300Open ↗
07/08/2013520134300Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026S00984125-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026S00984125-I1Open ↗
▸Trade Schedules & Equipment2
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
11/18/2024500799674Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
11/18/2024500799674Open ↗
▸Environmental & Asbestos2
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
02/18/2014520134300Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/26/2013520134300Open ↗
▸Energy Compliance5
▸BISTR8: Energy Code Progress Inspections2
01/29/2014520134300Open ↗
07/08/2013520134300Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION (PTA4)2
12/09/2013520134300Open ↗
07/05/2013520134300Open ↗
▸BISEN2 - As Built Energy Analysis1
01/29/2014520134300Open ↗
▸Inspections & Test Reports1
▸BIS* STRUCTURAL STABILITY 1 RCNY:16-011
11/18/2024500799674Open ↗
▸Approvals, Objections & Sign-offs7
▸BISLETTERS - SUPPORTING DOCUMENTATION4
03/19/2024500799674Open ↗
01/29/2014520134300Open ↗
07/08/2013520134300Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE1
10/24/2024500799674Open ↗
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
12/09/2013520134300Open ↗
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST1
12/09/2013520134300Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/09/2013520134300Open ↗
07/08/2013520134300Open ↗
▸Filing & Intake Forms2
▸BISeFiling Job Application Cover Sheet1
07/05/2013520134300Open ↗
▸BISADDITIONAL INFORMATION1
04/29/2024500799674Open ↗
▸Other Documents2
▸BIS* FIRE STOPS 27-3451
11/18/2024500799674Open ↗
▸BIS* * SUBGRADE 27-723,DIRC 15/711
11/18/2024500799674Open ↗