← Back
Two family brick
604 IONIA AVENUE
STATEN ISLAND · BIN 5081486
💬 Discuss this project
1965Year Built
2Stories
B1Building Class
R3XZoning
2,000 sfGross Floor Area
2Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Two family brick · 4,000 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar4p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THINK DESIGN ARCHITECTURE611/03/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FINE MECHANICAL CORPPlumbing307/08/2026
CICCARELLI & ASSOCIATES *General Contractor207/08/2026
RITE-FLO P.H.& COOLING INPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738411/03/2025
Building Lifecycle
All (50)Filed (6)Permit Issued (7)Signed Off (3)Violation (10)Inspection (13)Special Inspection (11)
05/21/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/15/2026
Signed off — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-S4
05/07/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/28/2026
Permit issued — Plumbing
S01067121-S4-PL
03/16/2026
Signed off — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-I1
03/13/2026
Signed off — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-S6
11/13/2025
Permit issued — General Construction
S01067121-S6-GC-CX
11/03/2025
Filed — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-S6
07/14/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/11/2025
Filed — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-P1
05/10/2025
Violation issued (ECB, closed)
Construction
04/18/2025
Filed — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-S4
03/12/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/10/2025
Inspection — Pass-Final House Connection
Pass
View inspection ↗
02/04/2025
Permit issued — Plumbing
S19706562-S1-PL
02/04/2025
Permit issued — Plumbing
S98191061-S2-PL
12/05/2024
Violation issued (HPD, closed)
I
11/01/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/28/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/28/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/21/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/21/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/15/2024
Permit issued — Plumbing
S01067121-S2-PL
10/04/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/26/2024
Permit issued — Plumbing
S01067121-S1-PL
09/03/2024
Permit issued — General Construction
S01067121-I1-GC-CX
08/22/2024
Filed — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-I1
08/22/2024
Filed — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-S1
08/22/2024
Filed — Alteration
THIS APPLICATION SUPERSEDES #S01067121-S1 FILED TO LEGALIZE PLUMBING FIXTURES @ CELLAR AND RESOLVE ECB VIOLATION #35486466M. NO CHANGE IN USE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION. NO NEW CO TO BE ISSUED UNDER THIS APPLICATION.
S01067121-S2
06/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
06/17/2024
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
06/17/2024
Special inspection requirement — Mechanical Systems
anthony santoro
06/17/2024
Special inspection requirement — Final
anthony santoro
06/17/2024
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
06/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
06/17/2024
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
06/17/2024
Special inspection requirement — Maintenance information
anthony santoro
06/17/2024
Special inspection requirement — Permanent certificate
anthony santoro
06/17/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
06/17/2024
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
04/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/08/2023
Violation issued (HPD, closed)
A
11/03/2023
Violation issued (HPD, closed)
C
11/03/2023
Violation issued (ECB, closed)
Construction
10/12/2023
Violation issued (HPD, closed)
C
10/06/2023
Violation issued (HPD, closed)
C
09/01/2023
Violation issued (HPD, closed)
A
05/24/2023
Violation issued (ECB, closed)
Construction
11/21/2022
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFINE MECHANICAL CORP04/28/2026
DOB NOWGeneral ConstructionSigned-offCICCARELLI & ASSOCIATES *11/13/2025
DOB NOWPlumbingSigned-offFINE MECHANICAL CORP02/04/2025
DOB NOWPlumbingSigned-offFINE MECHANICAL CORP02/04/2025
DOB NOWPlumbingPermit IssuedDJ PLUMBING & HEATING COR10/15/2024
DOB NOWPlumbingPermit IssuedDJ PLUMBING & HEATING COR09/26/2024
DOB NOWGeneral ConstructionSigned-offCICCARELLI & ASSOCIATES *09/03/2024
1 project · most recent 11/03/2025
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/03/2025Signed-offCICCARELLI & ASSOCIATES *Heating Systems, Ventilation Systems
Heating
Trane TUD060C924J1 47,000 BTU · Furnace ×1
TUD100C945K0 80,000 BTU · Furnace ×1
Ventilation
Panasonic FV-1115VK2 150 CFM · Exhaust Fan ×1
1 project · most recent 11/03/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/03/2025Signed-offFINE MECHANICAL CORPGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
05/21/2026Pass-Final CND-Occupancy InspectionPassView ↗
05/07/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/14/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/12/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/10/2025Pass-Final House ConnectionPassView ↗
11/01/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/28/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/28/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/21/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/21/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/04/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
06/20/2024Fire-Resistant Penetrations and Jointsanthony santorospecial
06/17/2024Energy Code Compliance Inspectionsanthony santoroprogress
06/17/2024Mechanical Systemsanthony santorospecial
06/17/2024Finalanthony santoroprogress
06/17/2024Energy Code Compliance Inspectionsanthony santoroprogress
06/17/2024Fire-Resistance Rated Constructionanthony santoroprogress
06/17/2024HVAC-R and service water heating equipmentanthony santoroenergy_progress
06/17/2024Maintenance informationanthony santoroenergy_progress
06/17/2024Permanent certificateanthony santoroenergy_progress
06/17/2024HVAC-R and service water piping design and insulationanthony santoroenergy_progress
06/17/2024HVAC-R and service water heating system controlsanthony santoroenergy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026S01067121-S1Request digital key ↗
08/21/2026S01067121-S4Request digital key ↗
08/21/2026S01067121-S2Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWRestrictive Declaration/Easement 13
08/21/2026S01067121-S4Open ↗
08/13/2026S01067121-S6Open ↗
08/13/2026S01067121-P1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/21/2026S01067121-S4Open ↗
08/13/2026S01067121-P1Open ↗
08/13/2026S01067121-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026S01067121-S1Open ↗
08/23/2026S01067121-I1Open ↗
08/23/2026S01067121-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026S01067121-S1Open ↗
08/23/2026S01067121-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026S01067121-S6Open ↗
08/13/2026S01067121-I1Open ↗