| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/28/2026 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Goodman AVPTC 48,000 BTU · Ahu ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/28/2026 | — | — | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/28/2026 | — | — | Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/11/2026 | Permit Issued | BEYER CONSTRUCTION CORP | Fence |
| Firm | Filings | Most Recent |
|---|---|---|
| THINK DESIGN ARCHITECTURE | 3 | 08/28/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| BEYER CONSTRUCTION CORP | General Contractor | 1 | 06/28/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Permit Issued | BEYER CONSTRUCTION CORP | 06/22/2026 |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/24/2026 | Pass-Final Boiler Equipment Inspection | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/10/2026 | Energy Code Compliance Inspections | — | progress |
| 08/10/2026 | Fire-Resistance Rated Construction | — | progress |
| 08/10/2026 | Structural Wood Frame | — | progress |
| 08/10/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 08/10/2026 | Subgrade Inspections | — | special |
| 08/10/2026 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 08/10/2026 | Maintenance information | — | energy_progress |
| 08/10/2026 | Interior lighting power | — | energy_progress |
| 08/10/2026 | Concrete - Cast-In-Place | — | special |
| 08/10/2026 | Metering | — | energy_progress |
| 08/07/2026 | HVAC-R and service water heating system controls | — | energy_progress |
| 08/07/2026 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 08/07/2026 | HVAC-R and service water heating equipment | — | energy_progress |
| 08/07/2026 | Ventilation and air distribution system | — | energy_progress |
| 08/07/2026 | Insulation placement and R values | — | energy_progress |
| 08/07/2026 | Air barrier - visual inspection | — | energy_progress |
| 08/07/2026 | Mechanical Systems | — | special |
| 08/07/2026 | Final | — | progress |
| 08/07/2026 | Footing and Foundation | — | progress |
| 08/07/2026 | Air barrier — testing | — | energy_progress |
| 08/07/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 08/07/2026 | Fenestration air leakage | — | energy_progress |
| 08/07/2026 | Fenestration areas | — | energy_progress |
| 08/07/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 08/07/2026 | Permanent certificate | — | energy_progress |