← Back
Two stories - detached, small or mid-size
1818 CARLTON AVENUE
STATEN ISLAND · BIN 5084825
💬 Discuss this project
1970Year Built
2Stories
A1Building Class
R3XZoning
2,124 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction25p · 1 filing · 20 docs
Floor 1Under Construction24p · 1 filing · 20 docs
CellarUnder Construction20p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RAHMAN CONSULTING311/21/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WEST AZE603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GT & K CONSTRUCTION INCGeneral Contractor307/30/2026
HOD PIPING & HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP CONCRETE TESTING AND I6252311/21/2024
Building Lifecycle
All (19)Filed (3)Permit Issued (3)Inspection (11)Special Inspection (2)
08/28/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/29/2026
Permit issued — Structural
S01066403-S4-ST
05/11/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/29/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/09/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/21/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
11/06/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/05/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/05/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/27/2025
Permit issued — General Construction
S01066403-I1-GC
08/18/2025
Permit issued — Plumbing
S01066403-S5-PL
05/02/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
04/28/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/22/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
12/20/2024
Special inspection requirement — Energy Code Compliance Inspections
DAMIR RAHMAN
11/21/2024
Filed — Alteration
SUBSEQUENT PLUMBING APPLICATION IN CONJUNCTION WITH APPROVED GC #S01066403-I1. REPLACEMENT AND ADDITION OF PLUMBING FIXTURES ON FIRST AND SECOND FLOORS.NO WORK PROPOSED ON CELLAR LEVEL.
S01066403-S4
11/21/2024
Filed — Alteration
SUBSEQUENT PLUMBING APPLICATION IN CONJUNCTION WITH APPROVED GC #S01066403-I1. REPLACEMENT AND ADDITION OF PLUMBING FIXTURES ON FIRST AND SECOND FLOORS.NO WORK PROPOSED ON CELLAR LEVEL.
S01066403-S5
06/14/2024
Filed — Alteration
SUBSEQUENT PLUMBING APPLICATION IN CONJUNCTION WITH APPROVED GC #S01066403-I1. REPLACEMENT AND ADDITION OF PLUMBING FIXTURES ON FIRST AND SECOND FLOORS.NO WORK PROPOSED ON CELLAR LEVEL.
S01066403-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedGT & K CONSTRUCTION INC07/29/2026
DOB NOWGeneral ConstructionPermit IssuedGT K CONSTRUCTION08/27/2025
DOB NOWPlumbingPermit IssuedHOD PIPING & HEATING CORP08/18/2025
BISPLISSUEDG. CASTLELUCCI PLBG11/25/1998
BIS—ISSUEDCONSTRUCTION BY DONALD ROWE, JR.11/16/1998
1 project · most recent 11/21/2024
Gas Water/Sanitary
FiledStatusContractorScope
11/21/2024Permit IssuedHOD PIPING & HEATING CORPGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
08/28/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/11/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/29/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/09/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/21/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
11/06/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/05/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/05/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/02/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
04/28/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/22/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
12/20/2024Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
12/20/2024Energy Code Compliance InspectionsDAMIR RAHMANprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/20/2026S01066403-P1Request digital key ↗
08/20/2026S01066403-S5Request digital key ↗
08/20/2026S01066403-S4Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/20/2026S01066403-P1Open ↗
08/13/2026S01066403-I1Open ↗
▸Seals & Professional Certifications14
▸DOB NOWSpecial Inspector Seal & Signature6
08/31/2026S01066403-S4Open ↗
08/31/2026S01066403-S4Open ↗
08/31/2026S01066403-S4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/20/2026S01066403-S5Open ↗
08/20/2026S01066403-S4Open ↗
08/20/2026S01066403-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/31/2026S01066403-S4Open ↗
08/31/2026S01066403-S4Open ↗
08/29/2026S01066403-S5Open ↗
▸Other Documents4
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/20/2026S01066403-P1Open ↗
08/13/2026S01066403-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/20/2026S01066403-P1Open ↗
08/13/2026S01066403-I1Open ↗