← Back
One story - permanent living quarter
7111 HYLAN BOULEVARD
STATEN ISLAND · BIN 5087987
💬 Discuss this project
1975Year Built
1Stories
A2Building Class
R1-2Zoning
2,810 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · 10,050 sf lot · 0.28 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHRIS PONISI, ARCHITECT103/11/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DAWN PONISI103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738103/11/2023
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Signed Off (1)Violation (4)Inspection (1)Special Inspection (5)
06/12/2023
Signed off — Alteration
S00841067-I1
06/08/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/17/2023
Permit issued — General Construction
S00841067-I1-GC-CX
03/11/2023
Filed — Alteration
S00841067-I1
03/08/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
anthony santoro
03/08/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
anthony santoro
03/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
03/08/2023
Special inspection requirement — Structural Wood Frame
anthony santoro
03/08/2023
Special inspection requirement — Final
anthony santoro
01/09/2023
Violation issued (ECB, closed)
Construction
07/25/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/25/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/01/2013
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offPR03/17/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/08/2023Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/08/2023Construction Operations Influencing Adjacent Structuresanthony santorospecial
03/08/2023Structural Stability – Alterations of existing buildingsanthony santorospecial
03/08/2023Fire-Resistant Penetrations and Jointsanthony santorospecial
03/08/2023Structural Wood Frameanthony santoroprogress
03/08/2023Finalanthony santoroprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/23/2026S00841067-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026S00841067-I1Open ↗
08/23/2026S00841067-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026S00841067-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026S00841067-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026S00841067-I1Open ↗