← Back
Predominantly retail with other uses
7339 AMBOY ROAD
STATEN ISLAND · BIN 5089145
💬 Discuss this project
1945Year Built
2Stories
K4Building Class
R3AZoning
3,285 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: WOOD AVENUE 235 LLC · 6,750 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ADA203/21/2026
MASTER FIRE PREVENTION SYSTEMS203/21/2026
WOOD AVENUE 235 LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THINK DESIGN ARCHITECTURE204/28/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMERICAN HOME BUILDING ANDGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THINK DESIGN ARCHITECTURA683204/28/2025
Building Lifecycle
All (48)Filed (2)Permit Issued (1)Signed Off (1)Violation (19)Inspection (1)Special Inspection (24)
05/07/2026
Signed off — Alteration
S01145315-I1
12/18/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/26/2025
Violation issued (HPD, closed)
I
11/12/2025
Permit issued — General Construction
S01145315-I1-GC-CX
04/30/2025
Special inspection requirement — Mechanical Systems
Frank Martarella III
04/30/2025
Special inspection requirement — Final
Frank Martarella III
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
Frank Martarella III
04/30/2025
Special inspection requirement — Duct leakage testing, insulation and design
Frank Martarella III
04/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
Frank Martarella III
04/30/2025
Special inspection requirement — Air barrier - visual inspection
Frank Martarella III
04/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Frank Martarella III
04/30/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Frank Martarella III
04/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Frank Martarella III
04/30/2025
Special inspection requirement — Air barrier continuity plan testing
Frank Martarella III
04/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Frank Martarella III
04/30/2025
Special inspection requirement — Insulation placement and R values
Frank Martarella III
04/28/2025
Filed — Alteration
S01145315-P1
04/28/2025
Special inspection requirement — Air barrier continuity plan testing
01/16/2025
Special inspection requirement — Insulation placement and R values
01/16/2025
Special inspection requirement — Mechanical Systems
Frank Martarella III
01/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/16/2025
Special inspection requirement — Final
Frank Martarella III
01/16/2025
Special inspection requirement — Energy Code Compliance Inspections
01/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
01/16/2025
Special inspection requirement — Duct leakage testing, insulation and design
01/16/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
01/16/2025
Special inspection requirement — HVAC-R and service water heating equipment
01/16/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
01/16/2025
Special inspection requirement — Air barrier - visual inspection
12/12/2024
Filed — Alteration
S01145315-I1
01/18/2024
Violation issued (FDNY_ORDER, closed)
01/18/2024
Violation issued (FDNY_ORDER, closed)
01/18/2024
Violation issued (FDNY_ORDER, closed)
01/18/2024
Violation issued (FDNY_ORDER, closed)
01/18/2024
Violation issued (FDNY_ORDER, closed)
01/18/2024
Violation issued (FDNY_ORDER, closed)
11/30/2023
Violation issued (HPD, closed)
I
06/16/2023
Violation issued (FDNY_NOV, closed)
03/01/2023
Violation issued (FDNY_NOV, closed)
07/20/2010
Violation issued (ECB, closed)
Boilers
04/08/2009
Violation issued (ECB, closed)
Boilers
05/07/2007
Violation issued (ECB, closed)
Boilers
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/08/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/04/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/18/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAMERICAN HOME BUILDING AN11/12/2025
BISPLISSUEDJFR CONSTRUCTION CORP08/01/2012
BISOTISSUEDMASSERIA CONSTRUCTION COR07/23/2012
BISEQISSUEDMASSERIA CONSTRUCTION COR07/23/2012
BISFPISSUEDMASTER FIRE SYSTEMS, INC03/23/2012
BISOTISSUEDGORMAN & CARBONE CONTRACT04/19/2011
BISPLISSUEDPAT MCCANN P&H INC03/14/2011
BISOTISSUEDGORMAN & CARBONE CONTRACT03/09/2011
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
12/18/2025Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
04/30/2025Mechanical SystemsFrank Martarella IIIspecial
04/30/2025FinalFrank Martarella IIIprogress
04/30/2025Energy Code Compliance InspectionsFrank Martarella IIIprogress
04/30/2025Duct leakage testing, insulation and designFrank Martarella IIIenergy_progress
04/30/2025Fire-Resistance Rated ConstructionFrank Martarella IIIprogress
04/30/2025Air barrier - visual inspectionFrank Martarella IIIenergy_progress
04/30/2025HVAC-R and service water piping design and insulationFrank Martarella IIIenergy_progress
04/30/2025Fenestration and door U-factor and product ratingsFrank Martarella IIIenergy_progress
04/30/2025HVAC-R and service water heating equipmentFrank Martarella IIIenergy_progress
04/30/2025Air barrier continuity plan testingFrank Martarella IIIenergy_progress
04/30/2025Fire-Resistant Penetrations and JointsFrank Martarella IIIspecial
04/30/2025Insulation placement and R valuesFrank Martarella IIIenergy_progress
04/28/2025Air barrier continuity plan testing—energy_progress
01/16/2025Insulation placement and R values—energy_progress
01/16/2025Mechanical SystemsFrank Martarella IIIspecial
01/16/2025Fire-Resistant Penetrations and Joints—special
01/16/2025FinalFrank Martarella IIIprogress
01/16/2025Energy Code Compliance Inspections—progress
01/16/2025Fire-Resistance Rated Construction—progress
01/16/2025Duct leakage testing, insulation and design—energy_progress
01/16/2025Fenestration and door U-factor and product ratings—energy_progress
01/16/2025HVAC-R and service water heating equipment—energy_progress
01/16/2025HVAC-R and service water piping design and insulation—energy_progress
01/16/2025Air barrier - visual inspection—energy_progress
▾Documents — 72 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026S01145315-P1Request digital key ↗
08/20/2026S01145315-I1Request digital key ↗
▸Applications & Permits14
▸BISWORK PERMIT APPLICATION7
01/15/2015520085032Open ↗
10/01/2012520085032Open ↗
10/01/2012520085032Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
07/17/2012520085032Open ↗
07/17/2012520085032Open ↗
03/19/2012520093960Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
03/26/2012520093960Open ↗
▸Seals & Professional Certifications23
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
08/17/2012520093960Open ↗
07/20/2012520085032Open ↗
03/19/2012520093960Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026S01145315-P1Open ↗
08/24/2026S01145315-I1Open ↗
08/24/2026S01145315-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
03/19/2012520093960Open ↗
04/15/2011520063902Open ↗
03/01/2011520060200Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
03/19/2012520093960Open ↗
04/15/2011520063902Open ↗
03/01/2011520060200Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026S01145315-P1Open ↗
08/24/2026S01145315-I1Open ↗
08/24/2026S01145315-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026S01145315-I1Open ↗
08/20/2026S01145315-P1Open ↗
▸Trade Schedules & Equipment10
▸BISSELF-CERT PLUMBING NOTICE5
12/11/2012520085032Open ↗
08/13/2012520085032Open ↗
08/09/2012520085032Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE B - PLUMBING3
07/17/2012520085032Open ↗
05/18/2011520060200Open ↗
03/01/2011520060200Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA2
08/17/2012520093960Open ↗
08/13/2012520085032Open ↗
▸Environmental & Asbestos3
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
04/15/2011520063902Open ↗
03/01/2011520060200Open ↗
▸BISASBESTOS-CERTIFICATION (DEP ACP5)1
12/22/2011520085032Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY2
03/10/2011520060200Open ↗
03/02/2011520060200Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/20/2012520085032Open ↗
▸Approvals, Objections & Sign-offs7
▸BISADMINISTRATIVE OBJECTIONS5
03/19/2012520093960Open ↗
03/19/2012520093960Open ↗
12/22/2011520085032Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
08/17/2012520093960Open ↗
10/17/2011520063902Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
08/17/2012520093960Open ↗
07/17/2012520085032Open ↗
03/19/2012520093960Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
12/22/2011520085032Open ↗
04/15/2011520063902Open ↗
03/01/2011520060200Open ↗
▸BISADDITIONAL INFORMATION1
10/06/2011520063902Open ↗