← Back
Multi-story retail building (2+)
2242 HYLAN BOULEVARD
STATEN ISLAND · BIN 5114469
💬 Discuss this project
1990Year Built
2Stories
K2Building Class
R3-2Zoning
1,800 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Multi-story retail building (2+) · Owner of record: FA2242 LLC. · 1,802 sf lot · 1 FAR built · Flood zone X500
Locations of Work
ArchitectureLandscape
Floor 12p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2242-2248 HYLAN BLVD603/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FACTORY ENGINEERING WORKS PLLC511/30/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KON HO LEE CONSULTING ENGINEER PLL803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YUNG WAY CONSTRUCTION INC.General Contractor307/08/2026
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FACTORY ENGINEERING WORKS8855511/30/2023
Building Lifecycle
All (28)Filed (5)Permit Issued (3)Signed Off (3)Violation (5)Inspection (6)Special Inspection (6)
12/18/2023
Signed off — Alteration
REMOVE (1)FURNACE AND (1)H.W.H.; RELOCATE (1)LAVATORY AND (1)WATER CLOSET; INSTALL (2)HAND SINK,(1)3-COMP. SINK,(4)DEEP FRYER,(1)2-BURNER RANGE,(4)FLOOR DRAIN,AND(1)GREASE TRAP AT 1ST FLOOR. REMOVE(1)FURANCE AND (1)H.W.H. AT 2ND FLOOR.
S00894098-I1
12/15/2023
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL STORE AT 1ST FLOOR. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
S00894517-I1
12/14/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/30/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL STORE AT 1ST FLOOR. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
S00894517-P1
10/05/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/15/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/08/2023
Filed — Alteration
REMOVE (1)FURNACE AND (1)H.W.H.; RELOCATE (1)LAVATORY AND (1)WATER CLOSET; INSTALL (2)HAND SINK,(1)3-COMP. SINK,(4)DEEP FRYER,(1)2-BURNER RANGE,(4)FLOOR DRAIN,AND(1)GREASE TRAP AT 1ST FLOOR. REMOVE(1)FURANCE AND (1)H.W.H. AT 2ND FLOOR.
S00894098-P1
08/31/2023
Signed off — Alteration
S00882965-I1
07/27/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/27/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/25/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/29/2023
Permit issued — Plumbing
S00894098-I1-PL
06/29/2023
Permit issued — Mechanical Systems
S00894517-I1-GC-CX
06/28/2023
Filed — Alteration
REMOVE (1)FURNACE AND (1)H.W.H.; RELOCATE (1)LAVATORY AND (1)WATER CLOSET; INSTALL (2)HAND SINK,(1)3-COMP. SINK,(4)DEEP FRYER,(1)2-BURNER RANGE,(4)FLOOR DRAIN,AND(1)GREASE TRAP AT 1ST FLOOR. REMOVE(1)FURANCE AND (1)H.W.H. AT 2ND FLOOR.
S00894098-I1
06/28/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL STORE AT 1ST FLOOR. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
S00894517-I1
06/20/2023
Permit issued — Structural
S00882965-I1-GC-CX
06/13/2023
Filed — Alteration
S00882965-I1
06/13/2023
Special inspection requirement — Energy Code Compliance Inspections
Kui He
06/13/2023
Special inspection requirement — Fire-Resistance Rated Construction
Kui He
06/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kui He
06/01/2023
Special inspection requirement — Structural Wood Frame
Kui He
05/31/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kui He
05/31/2023
Special inspection requirement — Final
Kui He
02/17/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/17/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/17/2023
Violation issued (ECB, closed)
Construction
09/21/1992
Violation issued (FDNY_NOV, closed)
09/21/1992
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG06/29/2023
DOB NOWMechanical SystemsSigned-offB & A COMMERCIAL INC06/29/2023
DOB NOWStructuralSigned-offB & A COMMERCIAL INC06/20/2023
2 projects · most recent 06/28/2023
General Wiring
FiledStatusContractorScope
06/28/2023CompleteKWONG MING ELECTRIC INCGeneral Wiring
01/31/2023Permit IssuedANOTHER NYCER ELEC. CORP.3 meters
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
12/14/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/05/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/15/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/27/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/27/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/25/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
06/13/2023Energy Code Compliance InspectionsKui Heprogress
06/13/2023Fire-Resistance Rated ConstructionKui Heprogress
06/01/2023Fire-Resistant Penetrations and JointsKui Hespecial
06/01/2023Structural Wood FrameKui Heprogress
05/31/2023Structural Stability – Alterations of existing buildingsKui Hespecial
05/31/2023FinalKui Heprogress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/23/2026S00882965-I1Request digital key ↗
08/23/2026S00894098-P1Request digital key ↗
08/23/2026S00894098-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/23/2026S00894098-I1Open ↗
08/23/2026S00894098-P1Open ↗
08/22/2026S00894517-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
09/18/2026S00882965-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/18/2026S00882965-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/23/2026S00894098-P1Open ↗
08/23/2026S00894098-I1Open ↗
08/22/2026S00894517-P1Open ↗
Showing 3 of 5 on file for this type