← Back
One story - permanent living quarter
35 HELENE COURT
STATEN ISLAND · BIN 5115665
💬 Discuss this project
1980Year Built
1Stories
A2Building Class
R3-1Zoning
2,126 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
One story - permanent living quarter · 4,000 sf lot · 0.53 FAR built
Locations of Work
No floor-level scope or drawing coverage on file for this building.
Nothing on file for this building.
Building Lifecycle
All (14)Filed (1)Violation (1)Objection (2)Special Inspection (10)
09/29/2026
Objection raised — Scope
09/28/2026
Objection raised — Scope
07/30/2026
Filed — Alteration CO
APPLICATION FILED FOR A ONE-STORY VERTICAL ENLARGEMENT TO CREATE A THIRD STORY WITHIN THE NEW ROOF STRUCTURE OF AN EXISTING TWO-STORY, ONE-FAMILY DWELLING. NO CHANGE IN USE OR OCCUPANCY. ALL WORK AS PER PLANS FILED HEREWITH.
S01436279-I1
07/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/24/2026
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
07/24/2026
Special inspection requirement — Wood – Prefabricated I-Joists
07/24/2026
Special inspection requirement — Final
07/24/2026
Special inspection requirement — Fenestration air leakage
07/24/2026
Special inspection requirement — Air barrier - visual inspection
07/24/2026
Special inspection requirement — Fenestration areas
07/24/2026
Special inspection requirement — Lighting in dwelling units
07/24/2026
Special inspection requirement — Insulation placement and R values
07/24/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
04/06/2002
Violation issued (ECB, open)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WOODROSE ASSOCIATES103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VMT DESIGN WORKSHOP INC.107/30/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDN/A07/07/2005
BISPLISSUEDDUO PLUMBING & HTG CORP.06/21/2005
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
07/24/2026Structural Stability – Alterations of existing buildings—special
07/24/2026Construction Utilizing CLT or SCL, Type IV—special
07/24/2026Wood – Prefabricated I-Joists—special
07/24/2026Final—progress
07/24/2026Fenestration air leakage—energy_progress
07/24/2026Air barrier - visual inspection—energy_progress
07/24/2026Fenestration areas—energy_progress
07/24/2026Lighting in dwelling units—energy_progress
07/24/2026Insulation placement and R values—energy_progress
07/24/2026Fenestration and door U-factor and product ratings—energy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026S01436279-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026S01436279-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
09/29/2026S01436279-I1Open ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026S01436279-I1Open ↗
▸Other Documents1
▸DOB NOWSite Survey: Initial1
08/16/2026S01436279-I1Open ↗