| Owner | Filings | Most Recent |
|---|---|---|
| WHITE CASTLE SYSTEMS | 22 | 07/08/2026 |
| WHITE CASTLE | 1 | 03/21/2026 |
| 2221 K B REALTY | 3 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| DON PENN CONSULTING ENGINEER | 2 | 12/02/2022 |
| DYNAMIC ENGINEERING CONSULTANTS, PC | 1 | 12/02/2022 |
| CHIA-LING YUAN | 1 | 10/31/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| PCA DESIGN CONSULTANTS | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| GLOBAL FACILITY MANAGEMENT | General Contractor | 8 | 07/08/2026 |
| DAVID MILLER | Electrical | 1 | 03/21/2026 |
| MILLER DAVID | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CERTIFIED TESTING LABORAT | 396 | 1 | 10/31/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | GLOBAL FACILITY MANAGEMEN | 02/24/2026 |
| DOB NOW | General Construction | Permit Issued | GLOBAL FACILITY MANAGEMEN | 05/13/2025 |
| DOB NOW | General Construction | Permit Issued | GLOBAL FACILITY MANAGEMEN | 01/02/2024 |
| DOB NOW | General Construction | Permit Issued | GLOBAL FACILITY MANAGEMEN | 01/02/2024 |
| DOB NOW | General Construction | Permit Issued | GLOBAL FACILITY MANAGEMEN | 01/18/2023 |
| DOB NOW | General Construction | Permit Issued | GLOBAL FACILITY MANAGEMEN | 01/17/2023 |
| BIS | MH | ISSUED | MEDLEY AIR INC | 02/03/2012 |
| BIS | PL | ISSUED | UNFLAT & ASSOCIATES INC | 01/24/2012 |
| BIS | — | ISSUED | SPECTRUM SIGNS INC. | 04/21/2004 |
| BIS | — | ISSUED | SPECTRUM SIGNS INC. | 04/21/2004 |
| BIS | PL | ISSUED | BRANCH PLUMBING LLC | 03/28/1994 |
| BIS | SP | ISSUED | BRANCH PLUMBING LLC | 03/28/1994 |
| BIS | FP | ISSUED | SAFETY CONSULTANT INC. | 03/15/1994 |
| BIS | — | ISSUED | ACE SIGN & RIGGING CORP. | 03/01/1994 |
| BIS | — | ISSUED | ACE SIGN & RIGGING CORP. | 02/25/1994 |
| BIS | — | ISSUED | SERVICE SIGN ERECTORS | 12/09/1993 |
| BIS | PL | ISSUED | BRANCH PLUMBING LLC | 10/19/1993 |
| BIS | — | ISSUED | ZZI_MANAGEMENT CORP. | 03/30/1993 |
| BIS | EQ | ISSUED | ZZI_MANAGEMENT CORP. | 03/30/1993 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/02/2022 | Permit Issued | GLOBAL FACILITY MANAGEMEN | Heating and Air Conditioning Systems | Heat / Cool Aaon RN009-8-0-BB02-3G4 109,260 BTU · Rooftop Unit ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/02/2022 | — | — | Gas, Water/Sanitary |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/04/2022 | Final | KIRT DOBBINS | progress |
| 11/04/2022 | Mechanical Systems | — | special |
| 11/04/2022 | Final | — | progress |
| 10/28/2022 | Exterior Insulation and Finish Systems (EIFS) | KIRT DOBBINS | special |
| 10/28/2022 | Fire-Resistant Penetrations and Joints | KIRT DOBBINS | special |
| 10/28/2022 | Demolition | KIRT DOBBINS | special |
| 10/28/2022 | Energy Code Compliance Inspections | KIRT DOBBINS | progress |
| 10/28/2022 | Preliminary | KIRT DOBBINS | progress |
| 10/28/2022 | Final | KIRT DOBBINS | progress |
| 10/28/2022 | Air barrier - visual inspection | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Duct leakage testing, insulation and design | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Fenestration air leakage | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Exterior lighting power | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Fenestration areas | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Fenestration and door U-factor and product ratings | KIRT DOBBINS | energy_progress |
| 10/28/2022 | HVAC-R and service water heating equipment | KIRT DOBBINS | energy_progress |
| 10/28/2022 | HVAC-R and service water heating system controls | KIRT DOBBINS | energy_progress |
| 10/28/2022 | HVAC-R and service water piping design and insulation | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Interior lighting power | KIRT DOBBINS | energy_progress |
| 10/28/2022 | Insulation placement and R values | KIRT DOBBINS | energy_progress |