← Back
One family attached or semi-detached
HARRIS LANE
STATEN ISLAND · BIN 5174548
💬 Discuss this project
2021Year Built
2Stories
A5Building Class
R3-1Zoning
1,790 sfGross Floor Area
1Units
One family attached or semi-detached · 3,504 sf lot · 0.51 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof1p · 1 filing · 7 docs
Cellar1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HARRIS LANE DEVELOPMENT1907/08/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A+ EXPEDITING INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CARMINE'S MECHANICAL INCPlumbing707/08/2026
CARMINE'S MECHANICAL INCGeneral Contractor107/08/2026
NYSS LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN RIVER ENVIRONMENTAL7841104/03/2026
A TECH ENGINEERING NYC, P6738404/08/2025
DESIGN BUILD, SI, INC6114404/08/2025
STRIGA ARCHITECTURE, PLLC8026111/30/2021
Building Lifecycle
All (60)Filed (7)Permit Issued (9)Signed Off (4)Inspection (10)Objection (6)Special Inspection (24)
05/08/2026
Signed off — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
S01382817-I1
04/07/2026
Permit issued — Solar
S01382817-I1-SL
04/03/2026
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
S01382817-I1
04/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
04/03/2026
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
04/03/2026
Special inspection requirement — Final
ROBERT MASONE
04/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
04/03/2026
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
04/24/2025
Signed off — Alteration
INSTALLATION OF SANITARY FIXTURES, GAS FIXTURES WITH ASSOCIATED PIPING AND DRYWELLS, YARD DRAINS AND ASSOCIATED PIPING.
S00375887-I1
04/12/2025
Special inspection requirement — HVAC and service water heating equipment
Steven Savino
04/12/2025
Special inspection requirement — HVAC and service water heating system controls
Steven Savino
04/12/2025
Special inspection requirement — Maintenance information
Steven Savino
04/12/2025
Special inspection requirement — HVAC insulation and sealing
Steven Savino
04/12/2025
Special inspection requirement — Permanent certificate
Steven Savino
04/12/2025
Special inspection requirement — Soil Percolation Test - Individual On-Site Private Sewage Disposal Systems
anthony santoro
04/12/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Giuseppe Bonomo
04/12/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
04/12/2025
Special inspection requirement — Energy Code Compliance Inspections
Steven Savino
04/08/2025
Filed — Alteration
INSTALLATION OF SANITARY FIXTURES, GAS FIXTURES WITH ASSOCIATED PIPING AND DRYWELLS, YARD DRAINS AND ASSOCIATED PIPING.
S00375887-P3
03/27/2025
Signed off — Alteration
INSTALLATION OF AUTOMATIC WET SPRINKLER SYSTEM
S00435672-I1
03/12/2025
Filed — Alteration
INSTALLATION OF SANITARY FIXTURES, GAS FIXTURES WITH ASSOCIATED PIPING AND DRYWELLS, YARD DRAINS AND ASSOCIATED PIPING.
S00375887-P2
02/20/2025
Signed off — Alteration
S00367538-I1
02/20/2025
Special inspection requirement — Maintenance information
Steven Savino
02/20/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Giuseppe Bonomo
02/20/2025
Special inspection requirement — Soil Percolation Test - Individual On-Site Private Sewage Disposal Systems
anthony santoro
02/20/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
02/20/2025
Special inspection requirement — Energy Code Compliance Inspections
Steven Savino
02/20/2025
Special inspection requirement — HVAC and service water heating equipment
Steven Savino
02/20/2025
Special inspection requirement — HVAC and service water heating system controls
Steven Savino
02/20/2025
Special inspection requirement — HVAC insulation and sealing
Steven Savino
02/20/2025
Special inspection requirement — Permanent certificate
Steven Savino
02/19/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
02/06/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/15/2025
Permit issued — Plumbing
S00435672-I1-PL
01/15/2025
Permit issued — Plumbing
S00375887-I1-PL
01/14/2025
Permit issued — Curb Cut
S00367538-I1-CC
12/18/2024
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
12/16/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
09/06/2024
Filed — Alteration
S00367538-I1
12/27/2023
Permit issued — Plumbing
S00375887-I1-PL
12/27/2023
Permit issued — Plumbing
S00435672-I1-PL
05/09/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/09/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/08/2023
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
05/08/2023
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
05/02/2023
Filed — Alteration
INSTALLATION OF SANITARY FIXTURES, GAS FIXTURES WITH ASSOCIATED PIPING AND DRYWELLS, YARD DRAINS AND ASSOCIATED PIPING.
S00375887-P1
01/09/2023
Permit issued — Plumbing
S00435672-I1-PL
12/20/2022
Permit issued — Plumbing
S00375887-I1-PL
12/07/2021
Objection raised — Scope
12/07/2021
Objection resolved — Addressed
12/07/2021
Objection raised — Scope
12/07/2021
Objection resolved — Addressed
12/07/2021
Objection raised — Structural
12/07/2021
Objection resolved — Addressed
11/30/2021
Filed — Alteration
INSTALLATION OF AUTOMATIC WET SPRINKLER SYSTEM
S00435672-I1
11/15/2021
Special inspection requirement — Sprinkler Systems
Keith Striga
10/07/2021
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/07/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/04/2021
Permit issued — Plumbing
S00375887-I1-PL
10/01/2021
Filed — Alteration
INSTALLATION OF SANITARY FIXTURES, GAS FIXTURES WITH ASSOCIATED PIPING AND DRYWELLS, YARD DRAINS AND ASSOCIATED PIPING.
S00375887-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYSS LLC04/07/2026
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC01/15/2025
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC01/15/2025
DOB NOWCurb CutSigned-offCARMINE'S MECHANICAL INC01/14/2025
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC12/27/2023
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC12/27/2023
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC01/09/2023
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC12/20/2022
DOB NOWPlumbingSigned-offCARMINE'S MECHANICAL INC10/04/2021
BIS—ISSUEDMAXIMUM CONTRACTING INC09/11/2024
BIS—ISSUEDMAXIMUM CONTRACTING INC10/23/2023
BIS—ISSUEDMAXIMUM CONTRACTING INC02/20/2023
BIS—ISSUEDMAXIMUM CONTRACTING INC10/05/2022
BIS—ISSUEDMAXIMUM CONTRACTING INC02/23/2022
BIS—ISSUEDMAXIMUM CONTRACTING INC06/28/2021
3 jobs · most recent 05/22/2026
General Wiring
FiledStatusContractorScope
05/22/2026Permit IssuedSWITCH ELECT OF THE FIVE1 meters
04/03/2026CompleteNY SOLAR ELECTRICAL LLC—
03/19/2025CompleteCNB ELECTRICAL INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
02/19/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
02/06/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/18/2024Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
12/16/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
05/09/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/09/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/08/2023Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
05/08/2023Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
10/07/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/07/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
04/03/2026Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
04/03/2026Energy Code Compliance InspectionsROBERT MASONEprogress
04/03/2026FinalROBERT MASONEprogress
04/03/2026Fire-Resistant Penetrations and JointsROBERT MASONEspecial
04/03/2026Air barrier - visual inspectionROBERT MASONEenergy_progress
04/12/2025HVAC and service water heating equipment Steven Savinoenergy_progress
04/12/2025HVAC and service water heating system controls Steven Savinoenergy_progress
04/12/2025Maintenance informationSteven Savinoenergy_progress
04/12/2025HVAC insulation and sealing Steven Savinoenergy_progress
04/12/2025Permanent certificateSteven Savinoenergy_progress
04/12/2025Soil Percolation Test - Individual On-Site Private Sewage Disposal Systemsanthony santorospecial
04/12/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGiuseppe Bonomospecial
04/12/2025Subsurface Investigations (Borings/Test Pits)anthony santorospecial
04/12/2025Energy Code Compliance InspectionsSteven Savinoprogress
02/20/2025Maintenance informationSteven Savinoenergy_progress
02/20/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGiuseppe Bonomospecial
02/20/2025Soil Percolation Test - Individual On-Site Private Sewage Disposal Systemsanthony santorospecial
02/20/2025Subsurface Investigations (Borings/Test Pits)anthony santorospecial
02/20/2025Energy Code Compliance InspectionsSteven Savinoprogress
02/20/2025HVAC and service water heating equipment Steven Savinoenergy_progress
02/20/2025HVAC and service water heating system controls Steven Savinoenergy_progress
02/20/2025HVAC insulation and sealing Steven Savinoenergy_progress
02/20/2025Permanent certificateSteven Savinoenergy_progress
11/15/2021Sprinkler SystemsKeith Strigaspecial
▾Documents — 114 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch - Plumbing5
08/19/2026S00375887-I1Request digital key ↗
08/19/2026S00375887-P1Request digital key ↗
08/19/2026S00375887-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch1
08/17/2026S01382817-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Curb Cut1
08/21/2026S00367538-I1Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION8
04/03/2025540185752Open ↗
03/26/2025540185752Open ↗
11/02/2023540185752Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
03/20/2025540185752Open ↗
▸BISWORK PERMIT APPLICATION1
06/28/2021540185752Open ↗
▸Zoning, Tax Lot & Property Records9
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
10/02/2020540185752Open ↗
▸BISACCESS EASEMENT AGREEMENT1
03/05/2025540185752Open ↗
▸BISRESTRICTION: EASEMENT AGREEMENT1
02/25/2021540185752Open ↗
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
10/02/2020540185752Open ↗
▸BISVERIFY TAX LOT1
04/17/2025540185752Open ↗
▸BISEASEMENT AND RESTRICTIVE DECLARATIONS - SUPPPORTING DOCUMENTATION1
11/12/2020540185752Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
12/20/2024540185752Open ↗
▸BISZONING DIAGRAM1
02/25/2021540185752Open ↗
▸BISZONING RESOLUTION DETERMINATION1
10/02/2020540185752Open ↗
▸Seals & Professional Certifications27
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026S00375887-I1Open ↗
09/01/2026S00375887-I1Open ↗
09/01/2026S00375887-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026S00435672-I1Open ↗
08/19/2026S00375887-I1Open ↗
08/19/2026S00375887-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026S00375887-I1Open ↗
09/01/2026S00375887-I1Open ↗
08/28/2026S00375887-P2Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
02/22/2021540185752Open ↗
01/12/2021540185752Open ↗
11/19/2020540185752Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/02/2020540185752Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/02/2020540185752Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/02/2020540185752Open ↗
▸Trade Schedules & Equipment5
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)2
12/18/2024540185752Open ↗
10/02/2020540185752Open ↗
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
10/02/2020540185752Open ↗
▸BISSPRINKLER (SP) SIGNOFF1
04/15/2025540185752Open ↗
▸BISFIRE APPARATUS ACCESS ROADS FOR DEVELOPMENT: FDNY APPROVAL1
01/26/2021540185752Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREES SITE PLAN1
05/01/2024540185752Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
06/28/2021540185752Open ↗
▸BISSTREET TREE CHECKLIST1
10/02/2020540185752Open ↗
▸BISSTREET TREE SIGNOFF1
03/13/2025540185752Open ↗
▸Energy Compliance15
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
02/27/2025540185752Open ↗
06/28/2021540185752Open ↗
06/24/2021540185752Open ↗
Showing 3 of 4 on file for this type
▸BISFENESTRATION AIR LEAKAGE1
02/03/2025540185752Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
02/03/2025540185752Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
02/03/2025540185752Open ↗
▸BISFENESTRATION AREAS1
02/03/2025540185752Open ↗
▸BISAIR SEALING AND INSULATION - TESTING1
02/21/2025540185752Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
02/03/2025540185752Open ↗
▸BISLIGHTING IN DWELLING UNITS1
02/03/2025540185752Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
02/03/2025540185752Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
03/21/2025540185752Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/02/2020540185752Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026S00375887-I1Open ↗
▸Inspections & Test Reports18
▸BISTECHNICAL REPORT: RESPONSIBILITY4
06/24/2021540185752Open ↗
06/24/2021540185752Open ↗
10/02/2020540185752Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSOIL REPORT4
08/13/2026S00375887-I1Open ↗
08/13/2026S00375887-P2Open ↗
08/13/2026S00375887-P1Open ↗
Showing 3 of 4 on file for this type
▸BISFRAME (2008)/STRUCTURAL WOOD FRAME (2014) INSPECTION1
02/03/2025540185752Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
06/24/2021540185752Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
02/03/2025540185752Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
02/03/2025540185752Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
02/03/2025540185752Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
02/03/2025540185752Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
02/03/2025540185752Open ↗
▸BISSUBGRADE INSP / SOILS-SITE PREP1
02/03/2025540185752Open ↗
▸BISSOIL REPORT1
10/02/2020540185752Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00375887-I1Open ↗
▸Approvals, Objections & Sign-offs5
▸BISNYS DEC FRESHWATER WETLANDS APPROVAL1
10/02/2020540185752Open ↗
▸BISCURB CUT (CC) SIGNOFF1
02/20/2025540185752Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
01/26/2021540185752Open ↗
▸BISBSA/CPC APPROVAL1
10/02/2020540185752Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/17/2026S01382817-I1Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION5
04/03/2025540185752Open ↗
03/19/2025540185752Open ↗
11/02/2023540185752Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
10/02/2020540185752Open ↗
▸Other Documents8
▸BISELECTRIC VEHICLE SERVICE EQUIPMENT REQUIREMENTS1
02/03/2025540185752Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
08/14/2023540185752Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
10/02/2020540185752Open ↗
▸BISMAINTENANCE INFORMATION1
02/03/2025540185752Open ↗
▸BISPERMANENT CERTIFICATE1
02/03/2025540185752Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
10/02/2020540185752Open ↗
▸BISVENTILATION AND AIR DISTRIBUTION SYSTEM1
02/03/2025540185752Open ↗
▸BISPLOT DIAGRAM1
10/02/2020540185752Open ↗