← Back
STATEN ISLAND
61 SHADYSIDE AVENUE
STATEN ISLAND · BIN 5176299
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone AE
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 2Under Construction32p · 3 filings · 20 docs
Floor 1Under Construction29p · 3 filings · 20 docs
CellarUnder Construction30p · 2 filings · 20 docs
BasementUnder Construction27p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
INGRAVALLO203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A TECH ENGINEERING NYC, PLLC.107/14/2025
SANNA & LOCCISANO ARCHITECTS, P.C.305/10/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SANNA LOCCISANO ARCHITECTS P C603/21/2026
A TECH ENGINEERING NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INGRAVALLO CORPGeneral Contractor507/08/2026
FINE MECHANICAL CORPPlumbing107/08/2026
K.M.D MECHANICAL 1443 LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
C&P DESIGN CONSULTANT8472205/10/2024
SRA PLANNING & EXPEDITING5677112/28/2023
A TECH ENGINEERING NYC, P6738112/27/2023
RICHMOND TESTING LAB263112/27/2023
Building Lifecycle
All (65)Filed (4)Permit Issued (5)Violation (2)Inspection (4)Objection (20)Special Inspection (30)
05/19/2026
Permit issued — Foundation
S00980855-I1-GC-CX
04/25/2026
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
anthony santoro
10/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/15/2025
Permit issued — General Construction
S00980855-I1-GC-CX
07/14/2025
Filed — Alteration
S01080118-I1
07/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/28/2025
Violation issued (ECB, closed)
Construction
10/16/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
10/11/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/10/2024
Violation issued (ECB, closed)
Construction
10/08/2024
Permit issued — Plumbing
S39822118-S1-PL
09/19/2024
Permit issued — Plumbing
S00980855-S1-PL
07/25/2024
Permit issued — Structural
S00980855-I1-GC-CX
07/15/2024
Objection resolved — Addressed
07/10/2024
Special inspection requirement — Fire-Resistance Rated Construction
Stanislav Pilipenko
07/10/2024
Special inspection requirement — Energy Code Compliance Inspections
Stanislav Pilipenko
06/10/2024
Objection resolved — Addressed
06/10/2024
Objection resolved — Addressed
06/10/2024
Objection resolved — Addressed
06/10/2024
Objection resolved — Addressed
06/04/2024
Special inspection requirement — Fenestration air leakage
Stanislav Pilipenko
06/04/2024
Special inspection requirement — Air barrier - visual inspection
Stanislav Pilipenko
05/17/2024
Objection raised — Zoning
05/17/2024
Objection raised — Zoning
05/10/2024
Filed — New Building
Three-story two-family residence with built-in one car garage and two on-site parking pads.
S00980855-S2
05/06/2024
Objection resolved — Addressed
05/06/2024
Objection resolved — Addressed
05/06/2024
Objection resolved — Addressed
05/06/2024
Objection resolved — Addressed
05/06/2024
Objection resolved — Addressed
01/30/2024
Objection raised — Structural
01/30/2024
Objection raised — Structural
01/30/2024
Objection raised — Scope
01/30/2024
Objection raised — Zoning
01/30/2024
Objection raised — Scope
01/30/2024
Objection raised — Zoning
01/30/2024
Objection raised — Zoning
01/30/2024
Objection raised — Inspections
12/28/2023
Filed — New Building
Three-story two-family residence with built-in one car garage and two on-site parking pads.
S00980855-S1
12/27/2023
Filed — New Building
Three-story two-family residence with built-in one car garage and two on-site parking pads.
S00980855-I1
12/24/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
WILLIAM MONTAGUE
12/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Structural Steel - Details
RICHARD LEMANSKY
12/24/2023
Special inspection requirement — Wood – Prefabricated I-Joists
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Structural Steel - High Strength Bolting
RICHARD LEMANSKY
12/24/2023
Special inspection requirement — Structural Steel - Welding
RICHARD LEMANSKY
12/24/2023
Special inspection requirement — Subgrade Inspections
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Electric vehicle service equipment requirements
Stanislav Pilipenko
12/24/2023
Special inspection requirement — HVAC-R and service water heating system controls
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Concrete - Cast-In-Place
Stanislav Pilipenko
12/24/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Air barrier — testing
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Fenestration areas
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Metering
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Insulation placement and R values
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Fireplaces
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Permanent certificate
Stanislav Pilipenko
12/24/2023
Special inspection requirement — Interior lighting power
Stanislav Pilipenko
Latest 60 of 65 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedINGRAVALLO CORP05/19/2026
DOB NOWGeneral ConstructionPermit IssuedINGRAVALLO CORP07/15/2025
DOB NOWPlumbingPermit IssuedK.M.D MECHANICAL 1443 LLC10/08/2024
DOB NOWPlumbingPermit IssuedFINE MECHANICAL CORP09/19/2024
DOB NOWStructuralPermit IssuedINGRAVALLO CORP07/25/2024
1 project · most recent 05/10/2024
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/10/2024Permit IssuedINGRAVALLO CORPAir Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Luxaire AP series AP36BX21 3 tons · Fan Coil Indoor ×2
LX series TC4B36225 3 tons · Condensing Unit ×2
Heat / Cool
Daikin single zone swing inverter condenser RXB12AXVJU 1 tons · Condensing Unit ×2
wall mounted FTXB12AXVJU 12,000 BTU · Split System ×2
Ventilation
Broan B100S- HW 64 CFM · Erv ×2
B130E65RT 130 CFM · Erv ×2
1 project · most recent 05/10/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/10/2024Permit IssuedFINE MECHANICAL CORPGas, Storm, Water/Sanitary
1 project · most recent 03/20/2025
General Wiring
FiledStatusContractorScope
03/20/2025Permit IssuedFLIP CITY ELECT & FIRE LLGeneral Wiring
1 project · most recent 05/10/2024
Steel Wood
FiledStatusContractorScope
05/10/2024Permit IssuedINGRAVALLO CORPSteel, Wood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/07/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/16/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
10/11/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
04/25/2026Construction Utilizing CLT or SCL, Type IVanthony santorospecial
07/10/2024Fire-Resistance Rated ConstructionStanislav Pilipenkoprogress
07/10/2024Energy Code Compliance InspectionsStanislav Pilipenkoprogress
06/04/2024Fenestration air leakageStanislav Pilipenkoenergy_progress
06/04/2024Air barrier - visual inspectionStanislav Pilipenkoenergy_progress
12/24/2023Subsurface Investigations (Borings/Test Pits)WILLIAM MONTAGUEspecial
12/24/2023Fire-Resistant Penetrations and JointsStanislav Pilipenkospecial
12/24/2023Structural Steel - DetailsRICHARD LEMANSKYspecial
12/24/2023Wood – Prefabricated I-JoistsStanislav Pilipenkospecial
12/24/2023Fenestration and door U-factor and product ratingsStanislav Pilipenkoenergy_progress
12/24/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationStanislav Pilipenkospecial
12/24/2023Structural Steel - High Strength BoltingRICHARD LEMANSKYspecial
12/24/2023Structural Steel - WeldingRICHARD LEMANSKYspecial
12/24/2023Subgrade InspectionsStanislav Pilipenkospecial
12/24/2023Electric vehicle service equipment requirementsStanislav Pilipenkoenergy_progress
12/24/2023HVAC-R and service water heating system controlsStanislav Pilipenkoenergy_progress
12/24/2023Concrete - Cast-In-PlaceStanislav Pilipenkospecial
12/24/2023HVAC-R and service water piping design and insulationStanislav Pilipenkoenergy_progress
12/24/2023Air barrier — testing Stanislav Pilipenkoenergy_progress
12/24/2023Fenestration areasStanislav Pilipenkoenergy_progress
12/24/2023MeteringStanislav Pilipenkoenergy_progress
12/24/2023Insulation placement and R valuesStanislav Pilipenkoenergy_progress
12/24/2023FireplacesStanislav Pilipenkoenergy_progress
12/24/2023Permanent certificateStanislav Pilipenkoenergy_progress
12/24/2023Interior lighting powerStanislav Pilipenkoenergy_progress
Latest 25 of 32.
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026S00980855-S2Request digital key ↗
08/21/2026S00980855-S1Request digital key ↗
08/21/2026S00980855-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00980855-I1Open ↗
08/13/2026S00980855-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00980855-I1Open ↗
08/13/2026S00980855-P1Open ↗
▸Seals & Professional Certifications16
▸DOB NOWSpecial Inspector Seal & Signature8
09/02/2026S00980855-I1Open ↗
09/02/2026S00980855-I1Open ↗
09/02/2026S00980855-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026S00980855-S2Open ↗
08/21/2026S00980855-S1Open ↗
08/21/2026S00980855-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026S00980855-I1Open ↗
09/02/2026S00980855-I1Open ↗
08/24/2026S00980855-P1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S00980855-I1Open ↗
08/13/2026S00980855-P1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/13/2026S00980855-I1Open ↗
08/13/2026S00980855-P1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00980855-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026S00980855-I1Open ↗
08/13/2026S00980855-P1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026S00980855-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00980855-I1Open ↗
▸Other Documents5
▸DOB NOWSite Survey: Initial2
08/13/2026S00980855-P1Open ↗
08/13/2026S00980855-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00980855-I1Open ↗
08/13/2026S00980855-P1Open ↗
▸DOB NOWProperty Ownership Certification1
08/21/2026S00980855-I1Open ↗