0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
StructuralPlumbing
Floor 22p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Basement1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FJN DEVELOPEMENT3207/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
C&P DESIGN CONSULTANTS504/11/2025
STANLEY M. KREBUSHEVSKI, R.A.206/21/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FJN DEVELOPEMENT CORPGeneral Contractor803/21/2026
DUO PLUMBING & HTG CORP.Plumbing107/08/2026
QUALITY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
C&P DESIGN CONSULTANT8472404/11/2025
SRA PLANNING & EXPEDITING5677504/11/2025
Building Lifecycle
All (64)Filed (7)Permit Issued (5)Signed Off (3)Violation (3)Inspection (12)Objection (4)Special Inspection (30)
06/09/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-S3
06/03/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
05/29/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-S2
05/28/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-S1
05/28/2025
Permit issued — Curb Cut
S00983135-S3-CC
05/22/2025
Permit issued — Mechanical Systems
S00983135-S2-MS
05/02/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/14/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
WILLIAM MONTAGUE
04/14/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Stanislav Pilipenko
04/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stanislav Pilipenko
04/14/2025
Special inspection requirement — Energy Code Compliance Inspections
Stanislav Pilipenko
04/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
Stanislav Pilipenko
04/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Stanislav Pilipenko
04/14/2025
Special inspection requirement — Maintenance information
Stanislav Pilipenko
04/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
Stanislav Pilipenko
04/14/2025
Special inspection requirement — Permanent certificate
Stanislav Pilipenko
04/11/2025
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-P3
04/10/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/13/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/21/2024
Violation issued (ECB, closed)
Construction
12/21/2024
Violation issued (ECB, closed)
Construction
12/11/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/11/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/02/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-S3
11/13/2024
Violation issued (ECB, closed)
Construction
10/21/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-S2
10/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/08/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-P2
10/08/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stanislav Pilipenko
10/08/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Stanislav Pilipenko
10/08/2024
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
WILLIAM MONTAGUE
10/08/2024
Special inspection requirement — Energy Code Compliance Inspections
Stanislav Pilipenko
10/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
Stanislav Pilipenko
10/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Stanislav Pilipenko
10/08/2024
Special inspection requirement — Permanent certificate
Stanislav Pilipenko
10/08/2024
Special inspection requirement — Maintenance information
Stanislav Pilipenko
10/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
Stanislav Pilipenko
07/31/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
07/26/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/25/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/22/2024
Permit issued — Plumbing
S00983135-S1-PL
07/22/2024
Permit issued — Plumbing
S53922426-S1-PL
07/15/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-S1
07/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Subgrade Inspections
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Concrete - Cast-In-Place
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Structural Steel - Welding
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Fire-Resistance Rated Construction
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Structural Wood Frame
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Footing and Foundation
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Final
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Insulation placement and R values
WILLIAM MONTAGUE
07/09/2024
Special inspection requirement — Fenestration air leakage
WILLIAM MONTAGUE
06/21/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING OF PRIMARY RESIDENCE.2)INSTALLATION OF SPLIT-SYSTEM HEAT PUMP UNIT FOR HEATING AND COOLING OF APARTMENT RESIDENCE.3)INSTALLATION OF EXHAUST AND ERV
S00983135-P1
05/28/2024
Permit issued — Foundation
S00983135-I1-GC-CX
03/19/2024
Objection resolved — Addressed
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offFJN DEVELOPEMENT05/28/2025
DOB NOWMechanical SystemsSigned-offFJN DEVELOPEMENT05/22/2025
DOB NOWPlumbingSigned-offQUALITY PLUMBING, INC07/22/2024
DOB NOWPlumbingSigned-offDUO PLUMBING & HTG CORP.07/22/2024
DOB NOWFoundationPermit IssuedFJN DEVELOPEMENT05/28/2024
1 project · most recent 04/11/2025
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/11/2025Signed-offFJN DEVELOPEMENT CORPAir Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Luxaire AHU: AE42CX21G CU: TCF2B42T21SA 36,000 BTU · Split System ×1
AHU: JHETC48GBCS2N1A CU: TCF2B42T21SA 48,000 BTU · Split System ×1
Heat / Cool
Tosot AHU: TWH18ATDXD-D3DNA3AI HP: TWH18ATDXD-D3DNA3AO 22,000 BTU · Heat Pump Outdoor ×1
Heating
Navien NFB-200H 199,900 BTU · Boiler ×1
Ventilation
Fantech ATMO 200H 110 CFM · Erv ×1
N/A N/A - REPLACED BY SINGLE ERV - 89 CFM · Erv ×1
Panasonic FV-04VE1 30 CFM · Erv ×1
1 project · most recent 04/11/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/11/2025Signed-offQUALITY PLUMBING, INCGas, Storm, Water/Sanitary
1 project · most recent 06/21/2024
General Wiring
FiledStatusContractorScope
06/21/2024CompleteTRUE ELECTRIC CORP.General Wiring
1 project · most recent 04/11/2025
Wood
FiledStatusContractorScope
04/11/2025Signed-offFJN DEVELOPEMENT CORPWood
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
06/03/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
05/02/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/10/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/13/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/11/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/11/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/11/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/11/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/31/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/26/2024Pass-Final PL - UndergroundPassView ↗
07/25/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 39
DateRequirementInspectorRole
04/14/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesWILLIAM MONTAGUEspecial
04/14/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationStanislav Pilipenkospecial
04/14/2025Fire-Resistant Penetrations and JointsStanislav Pilipenkospecial
04/14/2025Energy Code Compliance InspectionsStanislav Pilipenkoprogress
04/14/2025HVAC-R and service water heating system controlsStanislav Pilipenkoenergy_progress
04/14/2025HVAC-R and service water piping design and insulationStanislav Pilipenkoenergy_progress
04/14/2025Maintenance informationStanislav Pilipenkoenergy_progress
04/14/2025HVAC-R and service water heating equipmentStanislav Pilipenkoenergy_progress
04/14/2025Permanent certificateStanislav Pilipenkoenergy_progress
10/08/2024Fire-Resistant Penetrations and JointsStanislav Pilipenkospecial
10/08/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationStanislav Pilipenkospecial
10/08/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesWILLIAM MONTAGUEspecial
10/08/2024Energy Code Compliance InspectionsStanislav Pilipenkoprogress
10/08/2024HVAC-R and service water heating system controlsStanislav Pilipenkoenergy_progress
10/08/2024HVAC-R and service water piping design and insulationStanislav Pilipenkoenergy_progress
10/08/2024Permanent certificateStanislav Pilipenkoenergy_progress
10/08/2024Maintenance informationStanislav Pilipenkoenergy_progress
10/08/2024HVAC-R and service water heating equipmentStanislav Pilipenkoenergy_progress
07/09/2024Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
07/09/2024Subgrade InspectionsWILLIAM MONTAGUEspecial
07/09/2024Concrete - Cast-In-PlaceWILLIAM MONTAGUEspecial
07/09/2024Subsurface Investigations (Borings/Test Pits)WILLIAM MONTAGUEspecial
07/09/2024Structural Steel - WeldingWILLIAM MONTAGUEspecial
07/09/2024Fire-Resistance Rated ConstructionWILLIAM MONTAGUEprogress
07/09/2024Structural Wood FrameWILLIAM MONTAGUEprogress
Latest 25 of 39.
▾Documents — 69 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/20/2026S00983135-P3Request digital key ↗
08/20/2026S00983135-S3Request digital key ↗
08/20/2026S00983135-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
02/20/2024540263007Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
03/11/2024540263007Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00983135-I1Open ↗
08/13/2026S00983135-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00983135-P1Open ↗
08/13/2026S00983135-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
03/11/2024540263007Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00983135-I1Open ↗
▸Seals & Professional Certifications31
▸DOB NOWProgress Inspector Seal & Signature14
09/27/2026S00983135-S1Open ↗
09/27/2026S00983135-S1Open ↗
09/27/2026S00983135-S1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/27/2026S00983135-S1Open ↗
09/27/2026S00983135-S1Open ↗
09/27/2026S00983135-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026S00983135-S1Open ↗
08/20/2026S00983135-P3Open ↗
08/20/2026S00983135-S3Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/20/2024540263007Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/20/2024540263007Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S00983135-P1Open ↗
08/13/2026S00983135-I1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026S00983135-P1Open ↗
08/13/2026S00983135-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00983135-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026S00983135-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00983135-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026S00983135-I1Open ↗
08/13/2026S00983135-P1Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
03/11/2024540263007Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00983135-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
03/11/2024540263007Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
02/20/2024540263007Open ↗
▸Other Documents10
▸BISBPP - SUPPORTING DOCUMENTATION2
11/25/2024540263007Open ↗
03/11/2024540263007Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026S00983135-P1Open ↗
08/13/2026S00983135-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00983135-I1Open ↗
08/13/2026S00983135-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/20/2026S00983135-P1Open ↗
08/20/2026S00983135-I1Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
11/25/2024540263007Open ↗
▸DOB NOWFinal Survey1
08/13/2026S00983135-I1Open ↗