ECB06/29/2026At the time of inspection of a proposed 1-story alteration, i observed an erected construction fence with an expired permit. Permit was issued on 08/21/2023 and expired on 08/21/2024. Failure to maintain a vali$1K due
ECB11/21/2024Failure to maintain building in code complaint manner; noted at front yard behind construction fence bags of garbage, plastic creates, cans, bottles, overgrown weeds, and downed tree branches., repair and/or re$3K due
DOB01/15/2024Failure to submit an acceptable inspectn rpt for structurally compromised bldg.
ECB07/10/2023At time of inspection observed approximately 15'-0" masonry load bearing wall removed and missing on rear facade cellar level at expo # 03. No shoring provided. Entire wall sitting without any support. Also exi$12K due
ECB09/13/2019Failure to maintain bldg in code compliant manner. Noted: at time of inspection i observed at exp#4 the brick facade is loose w/brick missing also bldg door is disrepair w/deteriorated & missing door siding exp$12K due
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB10/25/2023Unpermitted removal of chimney&lg sectn of exp#3@cellar lvl. Rear wall was shored under ied# 17756. This is only a temp solution & doesn't permanently address the compromised condition of exp#3 remedy: failure to comply. Retain nys rdp to develop perm repair plans file appl. Complete wrk perm rpr & waterproof by 12/31/23Issued 2023; DOB's record still lists it as active
DOB08/16/2023Emer wrk unpermited removal of chimney&lg sectin exp#3@cellar lvl lintels above cellar window&door unsupported@1 end. Fullvacate,potentl of collapse poses hazard 2 public,stability compromsed. Remedy: comply w code.immeditly retain nys rdp,cs&gc 2 stabilze site.submit s/s by 7/12/23&daily rpts til complet,start 12PM,7/12Issued 2023; DOB's record still lists it as active
DOB07/21/2023Brace and shore exposure 3 masonry wall and the unsupported steel grid er and lintels. Engineer to provide preliminary shoring plan to DOB prior to commencement of workIssued 2023; DOB's record still lists it as active
DOB07/12/2023Emergency wrk,unpermitted removal of chimney&lg sectn,exp#3@cellar lvl.lintels above cellar window&door unsupported@1 end.fullvacate, potential/collapse poses hazard 2 public,stability compromsed remedy:comply w code.immeditly retain nys rdp,cs&gc 2 stabilze site submit s/s by 7/12/23&daily rpts til complet,start 12PM,7/12/23Issued 2023; DOB's record still lists it as active
DOB07/11/2023Erect approximately 270 linear feet of tight baord construction fence to enclose property as follows: exp#1 35 ft, exp#3 35FT, exp#2 approx 100 ft, exp#4.approx. 100 lft to safeguard public and propertyIssued 2023; DOB's record still lists it as active
DOB07/10/2023Structure rendered non-compliant. At time of inspection damage observed to have been sustained on rear wall due to foundation wall removed without any support at 1001 huntington ave bronx. A full vacate order issued on entire building.Issued 2023; DOB's record still lists it as active
DOB07/10/2023At time of inspection observed approximately 15'-0" masonry load bearing wall removed and missing on rear facade cellar level at expo # 03. No shoring provided. Entire wall sitting without any support. Also existing masonry chimney bricks removed 1ST floor to roof level. Building structural stability compromised.Issued 2023; DOB's record still lists it as active
DOB12/11/2019Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2019; DOB's record still lists it as active
One story - permanent living quarter · 3,525 sf lot · 0.57 FAR built · Flood zone X