← Back
Elevator cooperative
1025 5 AVENUE
MANHATTAN · BIN 1046778
💬 Discuss this project
1955Year Built
13Stories
D4Building Class
R8BZoning
312,550 sfGross Floor Area
168Units
LL97 CoveredRent Stabilized1 Open Violation ▸FISP: SWARMP
Elevator cooperative · Owner of record: 1025 FIFTH AVE INC · 36,710 sf lot · 8.51 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipment
Permit Issued — active, not yet Signed-off
Roof2p · 2 filings · 13 docs
PenthouseUnder Construction16p · 4 filings · 20 docs
Floor 12Under Construction9p · 2 filings · 8 docs
Floor 11Under Construction21p · 6 filings · 20 docs
Floor 10
Floor 9
Floor 8Under Construction4p · 1 filing · 5 docs
Floor 7
Floor 6Under Construction8p · 3 filings · 20 docs
Floor 5Under Construction17p · 1 filing · 12 docs
Floor 4Under Construction2p · 1 filing · 4 docs
Floor 31p · 1 filing · 12 docs
Floor 2
Floor 11p · 1 filing · 4 docs
Cellar4p · 3 filings · 20 docs
Basement11p · 1 filing · 18 docs
Sub-BasementUnder Construction1 filing · 4 docs
2 jobs · most recent 06/15/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/15/2026Permit IssuedKMV-NY INCHeating and Air Conditioning Systems
Heat / Cool
Lg LG KNMLB121A 12,000 BTU · Vrf Indoor ×3
LG KNMLB181A 18,000 BTU ×2
LG KUMXB601A 5 tons · Heat Pump Outdoor ×2
LG KNMLB241A 24,000 BTU · Vrf Indoor ×1
LG KNMLB301A 30,000 BTU · Vrf Indoor ×1
LG KNUJB301A 30,000 BTU ×1
LG KUMXB481A 4 tons ×1
07/31/2024Permit IssuedQUADRANT DEVELOPMENTHeating and Air Conditioning Systems
Heat / Cool
Daikin FTQ48TAVJUA 1,500 CFM · Split System ×1
FXNQ07MVJU10 245 CFM · Vrf Indoor ×1
FXNQ07MVJU11 245 CFM · Vrf Indoor ×1
FXQ07MVJU9 245 CFM · Vrf Indoor ×1
RXTQ36TBVJUA 34,000 BTU · Vrf Outdoor ×1
RZQ48TBVJUA 48,000 BTU · Vrf Outdoor ×1
5 jobs · most recent 06/15/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/15/2026Permit IssuedTAP PLUMBING CORPGas, Water/Sanitary
04/29/2026——Gas, Water/Sanitary
03/16/2026Signed-offA.M.N. CORPORATIONGas, Water/Sanitary
08/06/2025Permit IssuedFIVE STAR P&H CO,INCGas, Water/Sanitary
03/31/2025Permit IssuedDYNAMIC PLBG & SPRKLR CORGas, Water/Sanitary
25 jobs · most recent 05/29/2026
General Wiring
FiledStatusContractorScope
05/29/2026Permit IssuedGLENDALE ELECTL CONTNG INGeneral Wiring
04/07/2026CompleteAMSTERDAM ELECTRIC CORPGeneral Wiring
03/18/2026Permit IssuedKYL ELECTRIC LLCGeneral Wiring
11/18/2025Permit IssuedCENTENNIAL ELEVATOR INDUSGeneral Wiring
06/12/2025Permit IssuedLAREDO ELECTRIC, INC.General Wiring
05/21/2025CompleteEVS ELECTRIC CORPGeneral Wiring
01/21/2025CompleteMATROS AUTOMATED ELEC'L CGeneral Wiring
11/20/2024CompleteAVALON ELECTRIC CORP.General Wiring
08/23/2024CompleteGLENDALE ELECTL CONTNG IN—
08/22/2024CompleteISTRA ELEC'L CONTRS CORPGeneral Wiring
07/27/2024CompleteKYL ELECTRIC LLCGeneral Wiring
05/14/2024CompleteEFCO ELECTRICAL SERVI INCGeneral Wiring
12/06/2023CompletePALANT ELEC'L CONTR'G COR—
11/08/2023CompleteESSEX ELECTRIC INCGeneral Wiring
06/13/2023CompleteARGON ELECTRICAL CORPGeneral Wiring
1 job · most recent 05/13/2026
Concrete
FiledStatusContractorScope
05/13/2026——Concrete
Building Lifecycle
All (300)Filed (64)Permit Issued (67)Signed Off (25)Facade (FISP) (6)Violation (5)Inspection (39)Objection (64)Special Inspection (30)
09/29/2026
Permit issued — General Construction
M01388745-I1-GC
09/09/2026
Permit issued — Protection and Mechanical Methods
M01275726-I1-PMM
07/31/2026
Permit issued — Plumbing
M01413771-I1-PL
07/31/2026
Special inspection requirement — Final
David Salamon
07/31/2026
Special inspection requirement — Masonry
David Salamon
07/31/2026
Special inspection requirement — Tenant Protection Plan Compliance
07/30/2026
Filed — Alteration
Facade repair
M00991561-P1
07/30/2026
Permit issued — General Construction
M01408313-I1-GC
07/30/2026
Permit issued — Mechanical Systems
M01413658-I1-MS
07/23/2026
Permit issued — General Construction
M01354979-I1-MS
07/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/19/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/30/2026
Objection resolved — Resolved
06/30/2026
Objection resolved — Resolved
06/30/2026
Objection resolved — Resolved
06/30/2026
Objection resolved — Resolved
06/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Gregory Perotto
06/30/2026
Special inspection requirement — Masonry
Gregory Perotto
06/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Gregory Perotto
06/23/2026
Objection raised — Scope
06/23/2026
Objection raised — Cost
06/23/2026
Objection raised — Scope
06/23/2026
Objection raised — Cost
06/16/2026
Filed — Alteration
#8799 - INSTALLATION OF NON-BEARING PARTITIONS AND FINISHES. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
M01408313-I1
06/15/2026
Filed — Alteration
8799 - Installation of HVAC Units. No change in egress, use, or occupancy.
M01413658-I1
06/15/2026
Filed — Alteration
#8799 - Plumbing modifications in Penthouse ABN. No change to egress, use, or occupancy.
M01413771-I1
06/08/2026
Special inspection requirement — Energy Code Compliance Inspections
Gregory Perotto
06/08/2026
Special inspection requirement — Tenant Protection Plan Compliance
Gregory Perotto
06/08/2026
Special inspection requirement — HVAC-R and service water heating system controls
Gregory Perotto
06/08/2026
Special inspection requirement — HVAC-R and service water heating equipment
Gregory Perotto
06/08/2026
Special inspection requirement — Final
Gregory Perotto
06/08/2026
Special inspection requirement — Mechanical Systems
Gregory Perotto
06/08/2026
Special inspection requirement — Fireplaces
Gregory Perotto
06/08/2026
Special inspection requirement — Duct leakage testing, insulation and design
Gregory Perotto
06/08/2026
Special inspection requirement — Ventilation and air distribution system
Gregory Perotto
06/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Gregory Perotto
06/08/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Gregory Perotto
06/08/2026
Special inspection requirement — Tenant Protection Plan Compliance
Gregory Perotto
06/08/2026
Special inspection requirement — Heating Systems
Gregory Perotto
06/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Gregory Perotto
06/08/2026
Special inspection requirement — Energy Code Compliance Inspections
Gregory Perotto
06/08/2026
Special inspection requirement — Permanent certificate
Gregory Perotto
06/08/2026
Special inspection requirement — Maintenance information
Gregory Perotto
05/29/2026
Permit issued — Plumbing
M01361504-S1-PL
05/27/2026
Permit issued — General Construction
M01361504-I1-GC
05/27/2026
Objection resolved — Addressed
05/27/2026
Special inspection requirement — Final
Gregory Perotto
05/27/2026
Special inspection requirement — Tenant Protection Plan Compliance
Gregory Perotto
05/26/2026
Objection raised — Structural
05/15/2026
Permit issued — General Construction
M01382764-I1-GC
05/14/2026
Objection resolved — Addressed
05/14/2026
Objection resolved — Addressed
05/13/2026
Filed — Alteration
REPAIR CONCRETE SLAB UNDER THE GROUND LEVEL GARDEN. No change to occupancy, use or egress.
M01199734-I1
05/13/2026
Objection raised — Scope
05/13/2026
Objection raised — Cost
05/12/2026
Objection resolved — Addressed
05/12/2026
Objection resolved — Addressed
05/11/2026
Objection raised — Structural
05/11/2026
Objection raised — Scope
05/05/2026
Permit issued — General Construction
M01175561-I1-GC
Latest 60 of 300 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WJE1107/08/2026
1025 FIFTH AVENEUE14103/22/2026
CITY DESIGN SERVICES203/22/2026
CREGGAN ELECTRICAL CORP103/22/2026
1025 5TH AVENUE2303/21/2026
C O GREENTHAL MANAGEMENT303/21/2026
1025 FIFTH AVE INC % GREENTHAL2303/21/2026
1025 5TH603/21/2026
KENWAY CONSTRUCTION103/21/2026
1025 5TH AVE INC C O GREENTHAL303/21/2026
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EMPIRE NY INSTALLATIONS INCGeneral Contractor1807/08/2026
NEW AMSTERDAM RESTORATIONGeneral Contractor1409/10/2026
BREEMAC LLCGeneral Contractor1203/21/2026
STANLEY RUTH CO LLCGeneral Contractor507/08/2026
BRENER CONSTRUCTION 212General Contractor507/08/2026
HARD SAFARI CORPGeneral Contractor507/08/2026
SUPERB PLUMBING & HEATINGPlumbing407/08/2026
ON SITE NYC INCGeneral Contractor407/25/2026
FOWA INTERIOR CORPGeneral Contractor407/08/2026
W3M INCGeneral Contractor303/21/2026
QUADRANT DEVELOPMENTGeneral Contractor307/08/2026
CITY DESIGN SERVICES LTDGeneral Contractor307/08/2026
KMV-NY INCGeneral Contractor307/31/2026
FIVE STAR P&H CO,INCPlumbing207/08/2026
A.M.N. CORPORATIONPlumbing207/08/2026
J P MALONEY INCGeneral Contractor204/09/2026
HIM & WILMAN HOME IMPROVEGeneral Contractor207/08/2026
JARLATH CONNAUGHTONGeneral Contractor203/21/2026
ASTRO ELECL CONTNG INCElectrical203/22/2026
ROBERT COVELLOElectrical203/21/2026
HELLO CHAPTER LLCGeneral Contractor207/08/2026
PRECISION BUILDING & CONSGeneral Contractor207/08/2026
ISTRA ELEC'L CONTR'S CORPElectrical103/22/2026
H POWER ELECTRIC INCElectrical103/22/2026
DICKSON, CHARDElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SALAMON ENGINEERING PLLC1264207/30/2026
GREGORY V. PEROTTO, P.E.947506/16/2026
URBAN INTEGRATIONS LLC7993705/13/2026
MALETZ DESIGN3250204/29/2026
MUNICIPAL TESTING LABORAT230104/22/2026
AMERICAN CONSTRUCTION TES9731204/10/2026
BIG APPLE GROUP NY A RMA9168403/27/2026
ADAL ENGINEERING PLLC42051303/27/2026
INTEGRITY CONSULTING SERV666202/18/2026
A2 ARCHITECT, PC2504203/31/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedSTREAMLINE USA LLC09/29/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedNEW AMSTERDAM RESTORATION09/09/2026
DOB NOWPlumbingPermit IssuedTAP PLUMBING CORP07/31/2026
DOB NOWGeneral ConstructionPermit IssuedKMV-NY INC07/30/2026
DOB NOWMechanical SystemsPermit IssuedKMV-NY INC07/30/2026
DOB NOWGeneral ConstructionPermit IssuedON SITE NYC INC07/23/2026
DOB NOWPlumbingPermit IssuedZ.W. PLBG & HTG CORP05/29/2026
DOB NOWGeneral ConstructionPermit IssuedRADEK SZCZESNY05/27/2026
DOB NOWGeneral ConstructionPermit IssuedGB CONSTRUCTION DESIGN05/15/2026
DOB NOWGeneral ConstructionPermit IssuedHELLO CHAPTER LLC05/05/2026
DOB NOWPlumbingPermit IssuedCROSSFIELD PLBG.&HTG04/02/2026
DOB NOWGeneral ConstructionPermit IssuedQUADRANT DEVELOPMENT03/17/2026
DOB NOWMechanical SystemsPermit IssuedON SITE NYC INC03/10/2026
DOB NOWGeneral ConstructionPermit IssuedT&D UNITED CONSTR CO, INC03/10/2026
DOB NOWGeneral ConstructionPermit IssuedON SITE NYC INC03/06/2026
DOB NOWPlumbingPermit IssuedFIVE STAR P&H CO,INC02/24/2026
DOB NOWPlumbingSigned-offA.M.N. CORPORATION12/04/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedNEW AMSTERDAM RESTORATION09/08/2025
DOB NOWSuspended ScaffoldSigned-offNEW AMSTERDAM RESTORATION08/11/2025
DOB NOWMechanical SystemsPermit IssuedQUADRANT DEVELOPMENT07/17/2025
DOB NOWGeneral ConstructionSigned-offHARD SAFARI CORP07/10/2025
DOB NOWGeneral ConstructionSigned-offHARD SAFARI CORP07/08/2025
DOB NOWSupported ScaffoldSigned-offNEW AMSTERDAM RESTORATION06/09/2025
DOB NOWGeneral ConstructionPermit IssuedNEW AMSTERDAM RESTORATION05/29/2025
DOB NOWSidewalk ShedSigned-offNEW AMSTERDAM RESTORATION05/22/2025
DOB NOWProtection and Mechanical MethodsSigned-offNEW AMSTERDAM RESTORATION05/22/2025
DOB NOWPlumbingPermit IssuedCITYWIDE PLBG HTG & SPKLS05/15/2025
DOB NOWGeneral ConstructionPermit IssuedHELLO CHAPTER LLC05/12/2025
DOB NOWGeneral ConstructionSigned-offJ P MALONEY INC04/10/2025
DOB NOWPlumbingPermit IssuedFIVE STAR P&H CO,INC03/26/2025
DOB NOWGeneral ConstructionPermit IssuedQUADRANT DEVELOPMENT03/21/2025
DOB NOWPlumbingSigned-offA.M.N. CORPORATION12/13/2024
DOB NOWGeneral ConstructionSigned-offHARD SAFARI CORP11/06/2024
DOB NOWGeneral ConstructionPermit IssuedKMV-NY INC09/23/2024
DOB NOWGeneral ConstructionSigned-offON SITE NYC INC09/10/2024
DOB NOWGeneral ConstructionSigned-offPRECISION BUILDING & CONS09/10/2024
DOB NOWMechanical SystemsSigned-offPRECISION BUILDING & CONS09/06/2024
DOB NOWPlumbingSigned-offBROOK PLUMBING & HTG CORP09/05/2024
DOB NOWGeneral ConstructionSigned-offJ P MALONEY INC08/13/2024
DOB NOWGeneral ConstructionSigned-offABILENE INC08/05/2024
+ 60 more permits on file
▾Field Inspections (DOB CAP) — 39
DateTypeResultReport
07/22/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/19/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/27/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
04/20/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/14/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/02/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/27/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/24/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/19/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/15/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/08/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/30/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/28/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/24/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/08/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/08/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/02/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/17/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/11/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
Latest 25 of 39.
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
07/31/2026MasonryDavid Salamonspecial
07/31/2026FinalDavid Salamonprogress
07/31/2026Tenant Protection Plan Compliance—special
06/30/2026Structural Stability – Alterations of existing buildingsGregory Perottospecial
06/30/2026MasonryGregory Perottospecial
06/30/2026Fire-Resistant Penetrations and JointsGregory Perottospecial
06/08/2026HVAC-R and service water heating system controlsGregory Perottoenergy_progress
06/08/2026Maintenance informationGregory Perottoenergy_progress
06/08/2026Fire-Resistant Penetrations and JointsGregory Perottospecial
06/08/2026Tenant Protection Plan ComplianceGregory Perottospecial
06/08/2026Energy Code Compliance InspectionsGregory Perottoprogress
06/08/2026Mechanical SystemsGregory Perottospecial
06/08/2026Fire-Resistant Penetrations and JointsGregory Perottospecial
06/08/2026Heating SystemsGregory Perottospecial
06/08/2026Tenant Protection Plan ComplianceGregory Perottospecial
06/08/2026Energy Code Compliance InspectionsGregory Perottoprogress
06/08/2026HVAC-R and service water heating equipmentGregory Perottoenergy_progress
06/08/2026Ventilation and air distribution systemGregory Perottoenergy_progress
06/08/2026HVAC-R and service water piping design and insulationGregory Perottoenergy_progress
06/08/2026Duct leakage testing, insulation and designGregory Perottoenergy_progress
06/08/2026FireplacesGregory Perottoenergy_progress
06/08/2026FinalGregory Perottoprogress
06/08/2026Permanent certificateGregory Perottoenergy_progress
05/27/2026FinalGregory Perottoprogress
05/27/2026Tenant Protection Plan ComplianceGregory Perottospecial
Latest 25 of 150.
▾Documents — 1,602 on file (BIS + DOB NOW)
▸Plans & Drawings73
▸DOB NOWPlans/Sketch66
09/06/2026M00043510-I1Request digital key ↗
09/06/2026M00053812-I1Request digital key ↗
09/03/2026M00493966-I1Request digital key ↗
Showing 3 of 66 on file for this type
▸DOB NOWPlans/Sketch - Plumbing6
09/05/2026M00311305-I1Request digital key ↗
09/04/2026M00339605-I1Request digital key ↗
09/04/2026M00340314-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Applications & Permits310
▸BISWORK PERMIT APPLICATION132
05/23/2025122508401Open ↗
04/02/2024100349197Open ↗
03/19/2024100349197Open ↗
Showing 3 of 132 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION116
01/21/2026122508401Open ↗
03/17/2025122508401Open ↗
03/25/2024100349197Open ↗
Showing 3 of 116 on file for this type
▸DOB NOWLPC Approval/Permit57
09/02/2026M00731210-I1Open ↗
09/02/2026M00766910-P1Open ↗
09/02/2026M00766910-I1Open ↗
Showing 3 of 57 on file for this type
▸BISDOT Permit - House Connection2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
10/26/2023103680009Open ↗
Showing 1 of 2 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications364
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION127
02/12/2020123416348Open ↗
02/12/2020123416348Open ↗
02/12/2020123416348Open ↗
Showing 3 of 127 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature74
09/06/2026M00043510-I1Open ↗
09/05/2026M00311305-I1Open ↗
09/05/2026M00311305-P1Open ↗
Showing 3 of 74 on file for this type
▸DOB NOWProgress Inspector Seal & Signature68
09/27/2026M01042419-S1Open ↗
09/27/2026M01042419-S1Open ↗
09/26/2026M01175561-I1Open ↗
Showing 3 of 68 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature49
09/27/2026M01042419-S1Open ↗
09/26/2026M01175561-I1Open ↗
09/17/2026M01100283-P4Open ↗
Showing 3 of 49 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST21
05/01/2019121552293Open ↗
Showing 1 of 21 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM13
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 13 on file for this type
▸BISAPPLICANT OWNER SIGNATURE4
01/26/2021140997367Open ↗
Showing 1 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPC FULL REPORT3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
01/26/2021140997367Open ↗
Showing 1 of 2 on file for this type
▸Trade Schedules & Equipment127
▸BISSELF-CERT PLUMBING NOTICE51
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 51 on file for this type
▸BISSCHEDULE B - PLUMBING45
12/17/2020123768547Open ↗
12/16/2020101161047Open ↗
12/15/2020123768547Open ↗
Showing 3 of 45 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE18
03/13/2020123768547Open ↗
10/08/2019123768547Open ↗
06/17/2019123768547Open ↗
Showing 3 of 18 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT7
05/06/2019121552293Open ↗
05/01/2019121552293Open ↗
Showing 2 of 7 on file for this type
▸BISEQUIPMENT USE PERMITS6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸Safety & Tenant Protection21
▸BISTenant Protection Plan and Notes13
05/18/2020123820222Open ↗
12/30/2019123725371Open ↗
06/17/2019123768547Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWTenant Protection Plan7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISTPP1: TENANT PROTECTION PLAN1
02/13/2021140997367Open ↗
▸Environmental & Asbestos115
▸DOB NOWDEP ACP-5: Asbestos Assessment Report48
09/05/2026M00311305-P1Open ↗
09/05/2026M00311305-I1Open ↗
09/03/2026M00493966-I1Open ↗
Showing 3 of 48 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'29
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 29 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)25
01/26/2021140997367Open ↗
05/18/2020123820222Open ↗
12/30/2019123725371Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form6
08/26/2026M01112823-I1Open ↗
Showing 1 of 6 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Energy Compliance106
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS49
07/08/2020123832674Open ↗
02/12/2020123416348Open ↗
02/12/2020123416348Open ↗
Showing 3 of 49 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS26
08/05/2021123832674Open ↗
07/19/2021123725371Open ↗
12/28/2020123768547Open ↗
Showing 3 of 26 on file for this type
▸BISTR8: Energy Code Progress Inspections9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY8
08/05/2021123832674Open ↗
07/19/2021123725371Open ↗
06/30/2021123820222Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.6
09/02/2026M00766869-I1Open ↗
Showing 1 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
09/10/2021140997367Open ↗
06/30/2021123820222Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
01/26/2021140997367Open ↗
▸Inspections & Test Reports26
▸BISTECHNICAL REPORT: RESPONSIBILITY23
02/21/2024100349197Open ↗
02/20/2024100349197Open ↗
02/20/2024100349197Open ↗
Showing 3 of 23 on file for this type
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19753
04/09/2024100349197Open ↗
10/25/2023103680009Open ↗
04/20/2023104481794Open ↗
▸Approvals, Objections & Sign-offs160
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST59
10/26/2023103680009Open ↗
04/21/2023104481794Open ↗
09/10/2021140997367Open ↗
Showing 3 of 59 on file for this type
▸BISLANDMARKS APPROVAL42
01/26/2021140997367Open ↗
05/18/2020123820222Open ↗
01/17/2020123725371Open ↗
Showing 3 of 42 on file for this type
▸BISADMINISTRATIVE OBJECTIONS31
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 31 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION17
05/18/2020123820222Open ↗
06/21/2019123768547Open ↗
Showing 2 of 17 on file for this type
▸BISLANDMARKS SIGNOFF5
04/11/2023104481794Open ↗
09/10/2021140997367Open ↗
08/06/2021123832674Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLandmark Approval4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISBSA-CPC APPROVAL2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Cost, Insurance & Ownership123
▸BISCOST AFFIDAVIT115
10/25/2023103680009Open ↗
04/10/2023104481794Open ↗
08/05/2021123832674Open ↗
Showing 3 of 115 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW33
04/12/2023104481794Open ↗
09/10/2021140997367Open ↗
06/30/2021123820222Open ↗
▸Filing & Intake Forms126
▸BISEFILING COVER SHEET51
05/11/2020123820222Open ↗
05/04/2020123832674Open ↗
12/30/2019123725371Open ↗
Showing 3 of 51 on file for this type
▸BISADDITIONAL INFORMATION39
02/29/2024100349197Open ↗
01/26/2021140997367Open ↗
06/12/2020123832674Open ↗
Showing 3 of 39 on file for this type
▸BISBOROUGH INTAKE FORM27
04/02/2024100349197Open ↗
03/19/2024100349197Open ↗
07/15/2020123820222Open ↗
Showing 3 of 27 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET8
01/26/2021140997367Open ↗
Showing 1 of 8 on file for this type
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Other Documents35
▸DOB NOWProof of Historic Building13
09/02/2026M00731210-I1Open ↗
08/26/2026M01100283-P4Open ↗
Showing 2 of 13 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION9
05/06/2019121552293Open ↗
Showing 1 of 9 on file for this type
▸BISSupporting Document: Fee Exempt2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISDepartment of Consumer Affairs (DCA) Form2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BIS* FIRE STOPS 27-3452
04/09/2024100349197Open ↗
10/25/2023103680009Open ↗
▸BIS* VENT. SYS.-ENGINEER/INSTALLER 27-136,7792
04/09/2024100349197Open ↗
10/25/2023103680009Open ↗
▸DOB NOWCalculations2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWManufacturer's Specifications2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSEPTIC - SUPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type