← Back
BuildNYC
Multi-story retail building (2+)
1135 MORRIS PARK AVENUE
BRONX · BIN 2045696
💬 Discuss this project
1955Year Built
2Stories
K2Building Class
R4Zoning
15,672 sfGross Floor Area
15Units
2 Active Violations 0 unresolved · 2 paperwork only ▸
Multi-story retail building (2+) · Owner of record: Ermioni 1801 Realty · 15,000 sf lot · 1.04 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofAlma Realty CORP3p · 1 filing · 4 docs
Floor 1Animal Hospital of Morris Park2p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Animal Hospital of Morris Park604/09/2026
Ermiono 1801 Realty603/21/2026
Alma Realty503/22/2026
1801-1805 Williamsbridge403/21/2026
1801 LEE203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/19/2015$6.6M—— → —$421/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Frame Design Corps112/19/2025
AG Engineering107/28/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AR Engineer US203/21/2026
Summit Consulting & Expediting203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Master ComfortGeneral Contractor303/21/2026
Stat ElectricElectrical203/21/2026
Qec Electrical SvceElectrical103/21/2026
YMJ ElectricElectrical103/21/2026
Ars Restorationspecialty_contractor104/09/2026
Polgano PlumbingPlumbing103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Frame Design and Construction7971112/19/2025
AG Engineering8899107/28/2025
Building Lifecycle
All (34)Filed (2)Permit Issued (2)Signed Off (1)Violation (14)Objection (6)Special Inspection (9)
12/24/2025
Permit issued — General Construction
X01334566-I1-GC
12/19/2025
Filed — Alteration
X01334566-I1
12/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
SURESH WARREN
12/16/2025
Special inspection requirement — Final
SURESH WARREN
08/20/2025
Signed off — Alteration
INSTALLATION OF ONE (1) 2-TON MINI SPLIT SYSTEM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01230872-I1
08/11/2025
Permit issued — Mechanical Systems
X01230872-I1-MS
08/06/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
07/30/2025
Objection raised — Fire_Protection
07/30/2025
Objection raised — Cost
07/30/2025
Objection raised — Zoning
07/28/2025
Filed — Alteration
INSTALLATION OF ONE (1) 2-TON MINI SPLIT SYSTEM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01230872-I1
07/28/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ARIEL GOLSHAN
07/28/2025
Special inspection requirement — HVAC-R and service water heating system controls
ARIEL GOLSHAN
07/28/2025
Special inspection requirement — Maintenance information
ARIEL GOLSHAN
07/28/2025
Special inspection requirement — Energy Code Compliance Inspections
ARIEL GOLSHAN
07/28/2025
Special inspection requirement — HVAC-R and service water heating equipment
ARIEL GOLSHAN
05/23/2025
Special inspection requirement — Final
ARIEL GOLSHAN
05/23/2025
Special inspection requirement — Mechanical Systems
ARIEL GOLSHAN
09/04/2019
Violation issued (ECB, closed)
Unknown
09/04/2019
Violation issued (ECB, closed)
Unknown
01/07/2010
Violation issued (ECB, closed)
Unknown
07/15/2009
Violation issued (ECB, closed)
Construction
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/10/1994
Violation issued (ECB, closed)
Construction
09/13/1993
Violation issued (DOB, closed)
VPW*-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-DISMISSED
04/23/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/09/1991
Violation issued (ECB, closed)
Construction
09/09/1991
Violation issued (DOB, closed)
VP-VIOLATION UNSERVED ECB-ACTIVE
02/04/1991
Violation issued (DOB, closed)
VP-VIOLATION UNSERVED ECB-ACTIVE
02/04/1991
Violation issued (ECB, closed)
Construction
06/26/1989
Violation issued (ECB, closed)
Construction
06/26/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedArs Restoration12/24/2025
DOB NOWMechanical SystemsSigned-offMaster Comfort08/11/2025
BISPLISSUEDPolgano Plumbing07/15/2016
BISFPISSUEDMaster Fire Systems06/17/2016
BISPLISSUEDPolgano Plumbing05/25/2016
BISOTISSUEDP. Lino05/06/2016
BISOTISSUEDA & A Restoration04/14/2016
BISPLISSUEDAqueduct Plumbing & Mechanical03/06/2013
BISEQISSUEDDionisos Construction02/08/2013
BISOTISSUEDDionisos Construction02/08/2013
BISMHISSUEDBCS Construction Services10/16/2008
BISFPISSUEDMaster Fire Systems06/24/2005
BIS—ISSUEDNew York Sign City09/30/2003
BIS—ISSUEDNew York Sign City02/24/2003
BIS—ISSUEDNew York Sign City02/24/2003
BISPLISSUEDC.R.U. Mechan & Heating10/23/2002
BISOTISSUEDNara Service10/23/2002
BISPLISSUEDGeorge S. Bateman Plumbing & Heating10/26/1994
BISPLISSUEDMainland PLG. & Heating06/25/1993
BISEQISSUEDTafa Development06/21/1993
BISEQISSUEDTafa Development04/14/1993
BISOTISSUEDTafa Development04/14/1993
BISEQISSUEDTafa Development03/02/1993
BISOTISSUEDTafa Development03/02/1993
3 projects · most recent 07/25/2026
General Wiring
FiledStatusContractorScope
07/25/2026Permit IssuedAmor Electric—
12/29/2025Permit IssuedYMJ ElectricGeneral Wiring
09/10/2019CompleteQec Electrical SvceGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
12/17/2025Structural Stability – Alterations of existing buildingsSURESH WARRENspecial
12/16/2025FinalSURESH WARRENprogress
07/28/2025HVAC-R and service water piping design and insulationARIEL GOLSHANenergy_progress
07/28/2025HVAC-R and service water heating system controlsARIEL GOLSHANenergy_progress
07/28/2025Maintenance informationARIEL GOLSHANenergy_progress
07/28/2025Energy Code Compliance InspectionsARIEL GOLSHANprogress
07/28/2025HVAC-R and service water heating equipmentARIEL GOLSHANenergy_progress
05/23/2025FinalARIEL GOLSHANprogress
05/23/2025Mechanical SystemsARIEL GOLSHANspecial
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Animal Hospital of Morris ParkMedical / HealthcareFloor 1
Project X01334566 Alteration · Permit Entire · 12/19/2025
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026X01334566-I1Request digital key ↗
▸Applications & Permits16
▸BISWORK PERMIT APPLICATION9
07/15/2016220536604Open ↗
06/17/2016220535491Open ↗
06/17/2016220535491Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION7
06/24/2016220536604Open ↗
06/08/2016220535491Open ↗
05/05/2016240139408Open ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications27
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
06/24/2016220536604Open ↗
06/17/2016220535491Open ↗
06/17/2016220535491Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
06/24/2016220536604Open ↗
06/08/2016220535491Open ↗
04/20/2016240139408Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
06/24/2016220536604Open ↗
06/08/2016220535491Open ↗
04/12/2016220526394Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026X01230872-I1Open ↗
09/23/2026X01230872-I1Open ↗
08/23/2026X01334566-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026X01334566-I1Open ↗
08/13/2026X01230872-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026X01230872-I1Open ↗
08/23/2026X01334566-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/16/2008210073640Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/20/2016240139408Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/20/2016240139408Open ↗
▸Trade Schedules & Equipment7
▸BISSELF-CERT PLUMBING NOTICE2
04/08/2013220249023Open ↗
03/26/2013220249023Open ↗
▸BISSCHEDULE B - PLUMBING2
04/20/2016240139408Open ↗
01/23/2013220249023Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
11/03/2008210073640Open ↗
▸BISEQUIPMENT USE PERMITS1
11/03/2008210073640Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
06/24/2016220536604Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
04/12/2016220526394Open ↗
▸Environmental & Asbestos6
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
06/08/2016220535491Open ↗
04/20/2016240139408Open ↗
04/12/2016220526394Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
10/16/2008210073640Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026X01334566-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/23/2013220249023Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/20/2016240139408Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/20/2016240139408Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/20/2016240139408Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
10/17/2019220526394Open ↗
06/14/2016220526394Open ↗
05/26/2016220526394Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
01/23/2013220249023Open ↗
10/16/2008210073640Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/11/2009210073640Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT8
06/24/2016220536604Open ↗
06/08/2016220535491Open ↗
05/26/2016220526394Open ↗
Showing 3 of 8 on file for this type
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET5
06/24/2016220536604Open ↗
06/08/2016220535491Open ↗
04/12/2016220526394Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
04/20/2016240139408Open ↗
▸BISADDITIONAL INFORMATION1
05/05/2016240139408Open ↗