| Owner | Filings | Most Recent |
|---|---|---|
| PRO BUILDING MANAGEMENT | 67 | 07/08/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/02/2022 | $1.0M | — | Private party → Private party | $276/sf building |
| 11/01/2017 | $950K | — | ROOSEVELT PLAZA INC. → Private party | $251/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| JAMES NAPOLI | 17 | 06/05/2026 |
| ETRECTE LLC | 2 | 06/18/2025 |
| GIAP FLORES, PE | 1 | 03/25/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| MMSR CONSULTING GROUP LLC | 32 | 03/21/2026 |
| PATRIOT ENERGY SOLUTIONS CORP | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| TRI CITY CONSTRUCTION COR | General Contractor | 31 | 07/08/2026 |
| G&B PLUMBING&HEATING CORP | Plumbing | 6 | 07/08/2026 |
| TWO-TONE GROUP CORP | General Contractor | 4 | 07/08/2026 |
| PATRIOT ENERGY SOL CO | General Contractor | 1 | 07/08/2026 |
| V VASS ELECTRIC CORP 003699 | General Contractor | 1 | 03/22/2026 |
| STIVAN PLUMBING & HTG INC | Fire Protection | 1 | 07/08/2026 |
| STIVAN PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| DARINKO PLUMBING | General Contractor | 1 | 03/22/2026 |
| LINKED MECHANICAL LLC | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| BUILDTECH ENGINEERING | 6369 | 6 | 06/05/2026 |
| INTERNATIONAL GEOTEHCNICA | 1795 | 7 | 03/02/2026 |
| ETRECTE LLC | 8116 | 2 | 06/18/2025 |
| GFC CONSULTING ENGINEER P | 4127 | 1 | 03/25/2025 |
| M. INT'L ENGINEERING PLLC | 3129 | 5 | 03/17/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | TWO-TONE GROUP CORP | 01/27/2026 |
| DOB NOW | General Construction | Permit Issued | TWO-TONE GROUP CORP | 07/08/2025 |
| DOB NOW | Mechanical Systems | Signed-off | LINKED MECHANICAL | 03/27/2025 |
| DOB NOW | Solar | Signed-off | PATRIOT ENERGY SOL CO | 02/19/2025 |
| DOB NOW | Plumbing | Signed-off | DARINKO PLUMBING CO | 12/30/2024 |
| DOB NOW | General Construction | Permit Issued | TWO-TONE GROUP CORP | 04/12/2024 |
| DOB NOW | Sprinklers | Signed-off | STIVAN PLUMBING & HTG INC | 04/03/2024 |
| DOB NOW | Sprinklers | Signed-off | STIVAN PLBG & HTG INC | 04/03/2024 |
| DOB NOW | General Construction | Permit Issued | TRI CITY CONSTRUCTION COR | 08/04/2023 |
| DOB NOW | Construction Fence | Permit Issued | TRI CITY CONSTRUCTION COR | 06/22/2023 |
| DOB NOW | Foundation | Permit Issued | TRI CITY CONSTRUCTION COR | 06/22/2023 |
| DOB NOW | General Construction | Permit Issued | TRI CITY CONSTRUCTION COR | 06/22/2023 |
| DOB NOW | Structural | Permit Issued | TRI CITY CONSTRUCTION COR | 06/22/2023 |
| DOB NOW | Foundation | Permit Issued | TRI CITY CONSTRUCTION COR | 06/22/2023 |
| DOB NOW | Structural | Permit Issued | TRI CITY CONSTRUCTION COR | 04/11/2023 |
| DOB NOW | Foundation | Permit Issued | TRI CITY CONSTRUCTION COR | 02/22/2023 |
| DOB NOW | Earth Work | Permit Issued | TRI CITY CONSTRUCTION COR | 02/22/2023 |
| DOB NOW | General Construction | Permit Issued | TRI CITY CONSTRUCTION COR | 01/19/2023 |
| DOB NOW | Construction Fence | Permit Issued | TRI CITY CONSTRUCTION COR | 12/01/2022 |
| DOB NOW | Construction Fence | Permit Issued | TWO-TONE GROUP CORP | 07/21/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/05/2026 | Permit Issued | TWO-TONE GROUP CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PEFY-P18NMAU-E4 20,000 BTU · Vrf Indoor ×3 PFKY-P18NLMU-E,PFKY-P12NLMU-E 20 BTU · Vrf Indoor ×3 PMFY-P15NBMU-ER5 17,000 BTU · Vrf Indoor ×3 MXZ-SM48NAMHZ2-U1 54,000 BTU · Heat Pump Outdoor ×2 MXZ-SM42NAMHZ2-U1 48,000 BTU · Vrf Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/05/2026 | Signed-off | STIVAN PLUMBING & HTG INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/05/2026 | Signed-off | DARINKO PLUMBING CO | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/30/2025 | Complete | V. VASS ELECTRIC CORP | General Wiring |
| 02/08/2025 | Complete | MAK ELECTRICAL CONTR CORP | 1 meters |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/03/2022 | Permit Issued | TRI CITY CONSTRUCTION COR | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/27/2026 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 03/24/2026 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 12/01/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/05/2025 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 09/05/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/30/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 08/30/2024 | Certified Sprinkler - SP - Roughing | Certified | View ↗ |
| 05/31/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 05/24/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/08/2026 | Air barrier - visual inspection | Luis Pichardo | energy_progress |
| 06/08/2026 | Structural Stability – Alterations of existing buildings | Luis Pichardo | special |
| 06/08/2026 | Air barrier — testing | Luis Pichardo | energy_progress |
| 06/08/2026 | Interior lighting power | Luis Pichardo | energy_progress |
| 06/08/2026 | Masonry | Luis Pichardo | special |
| 06/08/2026 | Concrete - Cast-In-Place | Luis Pichardo | special |
| 06/08/2026 | Fire-Resistant Penetrations and Joints | Luis Pichardo | special |
| 06/08/2026 | Fenestration areas | Luis Pichardo | energy_progress |
| 06/08/2026 | HVAC-R and service water piping design and insulation | Luis Pichardo | energy_progress |
| 06/08/2026 | Permanent certificate | Luis Pichardo | energy_progress |
| 06/08/2026 | Protection of exposed foundation insulation | Luis Pichardo | energy_progress |
| 06/08/2026 | HVAC-R and service water heating system controls | Luis Pichardo | energy_progress |
| 06/08/2026 | Fenestration and door U-factor and product ratings | Luis Pichardo | energy_progress |
| 06/08/2026 | HVAC-R and service water heating equipment | Luis Pichardo | energy_progress |
| 06/08/2026 | Insulation placement and R values | Luis Pichardo | energy_progress |
| 06/08/2026 | Fenestration air leakage | Luis Pichardo | energy_progress |
| 06/08/2026 | Maintenance information | Luis Pichardo | energy_progress |
| 06/03/2026 | Masonry | Luis Pichardo | special |
| 06/03/2026 | Permanent certificate | Luis Pichardo | energy_progress |
| 06/03/2026 | Maintenance information | Luis Pichardo | energy_progress |
| 06/03/2026 | HVAC-R and service water heating system controls | Luis Pichardo | energy_progress |
| 06/03/2026 | Protection of exposed foundation insulation | Luis Pichardo | energy_progress |
| 06/03/2026 | HVAC-R and service water heating equipment | Luis Pichardo | energy_progress |
| 06/03/2026 | Interior lighting power | Luis Pichardo | energy_progress |
| 06/03/2026 | Fenestration areas | Luis Pichardo | energy_progress |