← Back
Walk-up apt, over six families with stores
1200 LEXINGTON AVENUE
MANHATTAN · Upper East Side-Carnegie Hill · BIN 1047560
💬 Discuss this project
1910Year Built
4Stories
C7Building Class
C1-8XZoning
12,104 sfGross Floor Area
18Units
Rent Stabilized0 Open Violations
Walk-up apt, over six families with stores · Owner of record: 1200 LEXINGTON LLC · 3,740 sf lot · 3.24 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof3p · 1 filing · 20 docs
Floor 19p · 1 filing · 20 docs
Cellar4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1200 LEXINGTON803/22/2026
1200 LEXINGTONLLC103/22/2026
ABRO MANAGEMENT303/22/2026
JEFFRIES MORRIS INC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FLUSHING ENGINEERING SERVICE PC512/06/2022
AKF ENGINEERS, LLP107/16/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HAOTIAN & ASSOCIATES INC.503/21/2026
JM ZONING, LLC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPLEN CONSTRUCTION INCGeneral Contractor207/08/2026
COLIN MCELWEEElectrical103/21/2026
GUH, DAVIDElectrical103/21/2026
JOE MIDDLETONElectrical103/21/2026
JOSEPH SGROIElectrical103/21/2026
MICHAEL BAPTISTEElectrical103/21/2026
PARGAS, RAYMONDElectrical103/21/2026
ROBERT COVELLOElectrical103/21/2026
SERTZEN, MANUELElectrical103/21/2026
TRITECH ELECTL & DATA INCElectrical103/22/2026
WEN BIN CENElectrical103/21/2026
ELYSIUM CONSTRUCTION INCGeneral Contractor107/08/2026
BRANDL ELECTRIC INC.Electrical103/22/2026
VILLAGE P & H NY INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FLUSHING ENGINEERING SERV4373512/06/2022
DNA CONTROLLED INSPECTION554107/16/2020
Building Lifecycle
All (29)Filed (6)Permit Issued (4)Signed Off (1)Violation (4)Special Inspection (14)
01/11/2023
Permit issued — Mechanical Systems
M00757893-S2-MS
12/06/2022
Filed — Alteration
HEREWITH FILING PLUMBING WORK TYPE TO AN EXISTING RETAIL SPACE AS PER PLAN. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
M00757893-S2
12/05/2022
Special inspection requirement — Duct leakage testing, insulation and design
KY FU
12/05/2022
Special inspection requirement — Tenant Protection Plan Compliance
KY FU
12/05/2022
Special inspection requirement — Mechanical Systems
KY FU
12/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
12/05/2022
Special inspection requirement — Final
KY FU
12/05/2022
Special inspection requirement — Energy Code Compliance Inspections
KY FU
12/05/2022
Special inspection requirement — Fire-Resistance Rated Construction
KY FU
10/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
10/04/2022
Filed — Alteration
HEREWITH FILING PLUMBING WORK TYPE TO AN EXISTING RETAIL SPACE AS PER PLAN. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
M00757893-P1
10/04/2022
Filed — Alteration
HEREWITH FILING PLUMBING WORK TYPE TO AN EXISTING RETAIL SPACE AS PER PLAN. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
M00757893-P2
09/16/2022
Special inspection requirement — Energy Code Compliance Inspections
KY FU
09/16/2022
Special inspection requirement — Fire-Resistance Rated Construction
KY FU
09/16/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
06/28/2022
Permit issued — Plumbing
M00757893-S1-PL
06/22/2022
Permit issued — General Construction
M00757893-I1-GC
06/21/2022
Filed — Alteration
HEREWITH FILING PLUMBING WORK TYPE TO AN EXISTING RETAIL SPACE AS PER PLAN. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
M00757893-S1
06/16/2022
Filed — Alteration
HEREWITH FILING PLUMBING WORK TYPE TO AN EXISTING RETAIL SPACE AS PER PLAN. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
M00757893-I1
02/02/2021
Signed off — Alteration
FILING HEREWITH FLUE EXTENSION OF EXISTING CHIMNEY AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00317551-I1
07/24/2020
Permit issued — Mechanical Systems
M00317551-I1-MS
07/16/2020
Filed — Alteration
FILING HEREWITH FLUE EXTENSION OF EXISTING CHIMNEY AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00317551-I1
02/21/2020
Special inspection requirement — Chimneys and vents
WILLIAM FITZJOHN
02/18/2020
Special inspection requirement — Mechanical Systems
WILLIAM FITZJOHN
02/18/2020
Special inspection requirement — Final
WILLIAM FITZJOHN
02/24/2005
Violation issued (ECB, closed)
Construction
09/01/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSPLEN CONSTRUCTION INC01/11/2023
DOB NOWPlumbingPermit IssuedVILLAGE P & H NY INC06/28/2022
DOB NOWGeneral ConstructionPermit IssuedSPLEN CONSTRUCTION INC06/22/2022
DOB NOWMechanical SystemsSigned-offELYSIUM CONSTRUCTION INC07/24/2020
BISEQISSUEDEMPIRE SCAFFOLDING SYSTEM08/30/2017
BISOTISSUEDRAPID MASONRY RESTORATION CORP10/04/2016
BISOTISSUEDHIRISE CONTRACTING GROUP06/08/2016
BISOTISSUEDSIGNS ARTISTRY AWNING CO*06/02/2016
BISOTISSUEDREAL DEAL DECORATION LLC09/21/2015
BISPLISSUEDCARRERAS HOME IMPROV INC06/10/2015
BISOTISSUEDREAL DEAL DECORATION LLC06/08/2015
BISMHISSUEDHD HVAC OF NY INC07/06/2007
BISPLISSUEDPETER PLUMBING ASSOC. INC.06/29/2007
BISOTISSUEDEIN CONTRACTING CORP06/14/2007
BISFPISSUEDNEW YORK BUSINESS FIRE SYTEM INC04/21/2005
BISMHISSUEDMAUREENS PASSION FOOD INC07/26/1999
BISEQISSUEDPSG CONSTRUCTION CO INC09/04/1998
BISMHISSUEDALL AIR CONDITIONING CO INC09/02/1997
BISOTISSUEDDONALD NAPP CONTRACTING CO07/24/1996
BISMHISSUEDBATU GAJAH CORP..01/08/1996
BISEQISSUEDBATU GAJAH CORP..10/20/1995
BISOTISSUEDBATU GAJAH CORP..10/20/1995
BISPLISSUEDD.DIAZ PLUMBING & HEATING CORP.02/21/1992
BISEQISSUEDJOSEPH TESTANTI, INC08/19/1991
1 project · most recent 12/06/2022
Water/Sanitary
FiledStatusContractorScope
12/06/2022Permit IssuedVILLAGE P & H NY INCWater/Sanitary
4 projects · most recent 05/07/2025
General Wiring
FiledStatusContractorScope
05/07/2025Permit IssuedWCK ELECTRIC CORP.General Wiring
06/06/2022Permit IssuedR & T ELECTRICAL CORPGeneral Wiring
10/22/2020CompleteTRITECH ELECTL & DATA INCGeneral Wiring
04/19/2018CompleteBRANDL ELECTRIC INC.—
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
12/05/2022Duct leakage testing, insulation and designKY FUenergy_progress
12/05/2022Tenant Protection Plan ComplianceKY FUspecial
12/05/2022Mechanical SystemsKY FUspecial
12/05/2022Fire-Resistant Penetrations and JointsKY FUspecial
12/05/2022FinalKY FUprogress
12/05/2022Energy Code Compliance InspectionsKY FUprogress
12/05/2022Fire-Resistance Rated ConstructionKY FUprogress
10/05/2022Fire-Resistant Penetrations and JointsKY FUspecial
09/16/2022Energy Code Compliance InspectionsKY FUprogress
09/16/2022Fire-Resistance Rated ConstructionKY FUprogress
09/16/2022Fire-Resistant Penetrations and JointsKY FUspecial
02/21/2020Chimneys and ventsWILLIAM FITZJOHNspecial
02/18/2020Mechanical SystemsWILLIAM FITZJOHNspecial
02/18/2020FinalWILLIAM FITZJOHNprogress
▾Documents — 106 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch5
09/01/2026M00757893-S2Request digital key ↗
09/01/2026M00757893-P2Request digital key ↗
09/01/2026M00757893-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00317551-I1Request digital key ↗
▸Applications & Permits16
▸BISPLAN / WORK APPROVAL APPLICATION9
08/29/2017140688502Open ↗
11/18/2016122790836Open ↗
09/20/2016122790836Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION7
08/29/2017140688502Open ↗
10/13/2016122790836Open ↗
06/08/2016140501614Open ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸BISZONING RESOLUTION DETERMINATION1
09/22/2016122790836Open ↗
▸Seals & Professional Certifications36
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
09/06/2018140688502Open ↗
05/24/2017122790836Open ↗
11/21/2016122790836Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/04/2026M00317551-I1Open ↗
09/01/2026M00757893-P2Open ↗
09/01/2026M00757893-S1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
08/29/2017140688502Open ↗
06/29/2016122790836Open ↗
06/07/2016122764936Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/28/2026M00317551-I1Open ↗
08/28/2026M00317551-I1Open ↗
08/28/2026M00757893-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/28/2026M00317551-I1Open ↗
08/28/2026M00757893-P1Open ↗
08/26/2026M00757893-S2Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
06/29/2016122790836Open ↗
06/07/2016122764936Open ↗
06/16/2015122427588Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
08/29/2017140688502Open ↗
06/05/2016140501614Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/29/2017140688502Open ↗
06/05/2016140501614Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/12/2015122427588Open ↗
06/16/2015122427588Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
12/28/2015122427588Open ↗
10/13/2015122427588Open ↗
▸Safety & Tenant Protection3
▸BISTENANT PROTECTION PLAN AND NOTES2
08/29/2017140688502Open ↗
06/29/2016122790836Open ↗
▸DOB NOWTenant Protection Plan1
09/04/2026M00317551-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
09/04/2026M00317551-I1Open ↗
09/01/2026M00757893-P2Open ↗
09/01/2026M00757893-P1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
09/20/2016122790836Open ↗
06/07/2016122764936Open ↗
06/16/2015122427588Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
08/23/2016140501614Open ↗
06/29/2016122790836Open ↗
06/16/2015122427588Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
05/24/2017122790836Open ↗
08/23/2016140501614Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/05/2016140501614Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
08/29/2017140688502Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/05/2016140501614Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
08/29/2017140688502Open ↗
06/05/2016140501614Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
09/06/2018140688502Open ↗
05/24/2017122790836Open ↗
08/23/2016140501614Open ↗
Showing 3 of 4 on file for this type
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
05/24/2017122790836Open ↗
08/23/2016140501614Open ↗
07/13/2016122764936Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION4
11/22/2016122790836Open ↗
07/27/2016140501614Open ↗
11/19/2015122427588Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET3
06/29/2016122790836Open ↗
06/07/2016122764936Open ↗
06/16/2015122427588Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
08/29/2017140688502Open ↗
06/05/2016140501614Open ↗
▸BISBOROUGH INTAKE FORM1
09/06/2018140688502Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
05/24/2017122790836Open ↗