| Owner | Filings | Most Recent |
|---|---|---|
| UJA- FEDERATION OF NEW YORL | 4 | 07/08/2026 |
| 13 59 60TH BUILDING | 49 | 07/08/2026 |
| TOWNHOUSE BUILDERS | 2 | 03/22/2026 |
| CENTRAL AVENUE DEVELOPERS LLC | 14 | 03/21/2026 |
| 43RD REALTY GROUP | 6 | 03/21/2026 |
| G G ASSOCIATES | 8 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/16/2024 | $10.9M | — | 13 59&60TH BUILDING LLC → Private party | $804/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| RICHARD WAINER ARCHITECT, PLLC | 1 | 10/16/2024 |
| LESTER KATZ, NCARB | 11 | 09/18/2024 |
| WEXLER ASSOCIATES | 5 | 04/18/2024 |
| MOHAMMAD AHEAD, PE | 2 | 09/26/2023 |
| FC CONSULTING ENGINEER, PLLC | 1 | 01/20/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPEDITER GROUP | 34 | 03/21/2026 |
| D R BROWN | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| TOWNHOUSE BUILDERS INC | General Contractor | 25 | 07/08/2026 |
| DYNAMIX SCAFFOLD GROUP LL | General Contractor | 4 | 03/21/2026 |
| P.H. WORKS INC | Plumbing | 2 | 07/08/2026 |
| SAFETY FIRE SPRINKLER CORP | Fire Protection | 1 | 07/08/2026 |
| LESTER KATZ | Electrical | 1 | 03/21/2026 |
| N Y SIGN ART | Scaffold | 1 | 07/08/2026 |
| MARK DUGAN | Electrical | 1 | 03/21/2026 |
| SPECTRUM ON BROADWAY-ELEC | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| BIG APPLE GROUP NY A RMA | 9168 | 14 | 09/18/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sign | Signed-off | SKANSKA BUILDING INC | 10/21/2024 |
| DOB NOW | Plumbing | Signed-off | SAFETY FIRE SPRINKLER CORP | 04/04/2024 |
| DOB NOW | Plumbing | Signed-off | P.H. WORKS INC | 03/22/2024 |
| DOB NOW | Earth Work | Signed-off | TOWNHOUSE BUILDERS INC | 01/09/2024 |
| DOB NOW | General Construction | Permit Issued | TOWNHOUSE BUILDERS INC | 11/20/2023 |
| DOB NOW | Structural | Signed-off | TOWNHOUSE BUILDERS INC | 11/15/2023 |
| DOB NOW | Construction Fence | Signed-off | TOWNHOUSE BUILDERS INC | 07/17/2023 |
| DOB NOW | Mechanical Systems | Signed-off | TOWNHOUSE BUILDERS INC | 07/17/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | DYNAMIX SCAFFOLD GROUP LL | 03/30/2023 |
| DOB NOW | Supported Scaffold | Signed-off | DYNAMIX SCAFFOLD GROUP LL | 03/30/2023 |
| DOB NOW | General Construction | Permit Issued | TOWNHOUSE BUILDERS INC | 03/21/2023 |
| DOB NOW | Sprinklers | Signed-off | P.H. WORKS INC | 03/21/2023 |
| DOB NOW | Structural | Signed-off | TOWNHOUSE BUILDERS INC | 03/20/2023 |
| DOB NOW | Foundation | Signed-off | TOWNHOUSE BUILDERS INC | 03/20/2023 |
| DOB NOW | Structural | Signed-off | TOWNHOUSE BUILDERS INC | 09/23/2022 |
| DOB NOW | Foundation | Signed-off | TOWNHOUSE BUILDERS INC | 09/23/2022 |
| DOB NOW | Support of Excavation | Signed-off | TOWNHOUSE BUILDERS INC | 08/15/2022 |
| DOB NOW | General Construction | Permit Issued | TOWNHOUSE BUILDERS INC | 08/10/2022 |
| DOB NOW | Construction Fence | Signed-off | TOWNHOUSE BUILDERS INC | 08/03/2022 |
| DOB NOW | General Construction | Signed-off | TOWNHOUSE BUILDERS INC | 08/02/2022 |
| DOB NOW | Mechanical Systems | Signed-off | TOWNHOUSE BUILDERS INC | 07/27/2022 |
| BIS | EQ | ISSUED | CHESAKL ENTERPRISES INC | 11/28/2022 |
| BIS | — | ISSUED | NORTH SHORE NEON SIGN CO | 05/08/2017 |
| BIS | — | ISSUED | SIGNS CAD CORP | 07/18/2012 |
| BIS | PL | ISSUED | STARLITE P & H | 04/22/1994 |
| BIS | PL | ISSUED | STARLITE PLBG & HTG | 05/25/1993 |
| BIS | — | ISSUED | PATRIOT CONSTR | 03/19/1993 |
| BIS | — | ISSUED | G & G ASSOC | 02/01/1993 |
| BIS | — | ISSUED | PATRIOT CONSTR | 01/28/1993 |
| BIS | OT | ISSUED | PATRIOT CONSTRUCTION INC. | 11/12/1991 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/18/2024 | Signed-off | TOWNHOUSE BUILDERS INC | Heating and Air Conditioning Systems, Refrigeration Systems, Ventilation Systems | Heat / Cool Daikin RXS242LVJU 21,400 BTU · Heat Pump Outdoor ×2 RXS242VJU 21,400 BTU · Heat Pump Outdoor ×2 RXYQ120XATJA 120,000 BTU · Vrf Outdoor ×2 RXYQ168ATJA 168,000 BTU · Vrf Outdoor ×2 RXYQ96XATJA 96,000 BTU · Vrf Outdoor ×2 Ventilation Greenheck N/A 1,100 CFM ×5 Energywall U-ERV-1800 1,800 CFM · Erv ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/18/2024 | Signed-off | SAFETY FIRE SPRINKLER COR | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/18/2024 | Signed-off | P.H. WORKS INC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/16/2024 | Complete | SPECTRUM ON BROADWAY-ELEC | — |
| 06/25/2024 | Complete | GREEN STAR ELECTL CONT IN | General Wiring |
| 11/07/2023 | Complete | GREEN STAR ELECTL CONT IN | — |
| 05/10/2023 | Complete | SPARK ELECTRICAL SVCS LLC | 1 meters, 1 new_meters |
| 03/31/2023 | Complete | HIGH QUALITY ELECTRIC OF | — |
| 03/31/2023 | Complete | TUXEDO ELEC'L CONTR'G INC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/18/2024 | Signed-off | SAFETY FIRE SPRINKLER COR | Steel, Concrete, Masonry |
| Date | Type | Result | Report |
|---|---|---|---|
| 10/03/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/31/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/04/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 05/30/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 03/25/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/01/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/22/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/02/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 07/11/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/12/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/24/2024 | Final | Richard Wainer | progress |
| 04/22/2024 | Final | Soorjbally Harilall | progress |
| 04/22/2024 | Structural Stability – Alterations of existing buildings | SOORJBALLY HARILALL | special |
| 04/22/2024 | Structural Steel - Welding | SOORJBALLY HARILALL | special |
| 04/22/2024 | Masonry | SOORJBALLY HARILALL | special |
| 04/22/2024 | Structural Steel - Details | SOORJBALLY HARILALL | special |
| 04/22/2024 | Concrete - Cast-In-Place | SOORJBALLY HARILALL | special |
| 04/22/2024 | Post-installed Anchors | SOORJBALLY HARILALL | special |
| 04/22/2024 | Structural Steel - High Strength Bolting | SOORJBALLY HARILALL | special |
| 04/17/2024 | HVAC-R and service water heating system controls | Soorjbally Harilall | energy_progress |
| 04/17/2024 | HVAC-R and service water heating equipment | Soorjbally Harilall | energy_progress |
| 04/17/2024 | HVAC-R and service water piping design and insulation | Soorjbally Harilall | energy_progress |
| 04/17/2024 | Energy Code Compliance Inspections | Soorjbally Harilall | progress |
| 04/17/2024 | Sprinkler Systems | SOORJBALLY HARILALL | special |
| 04/17/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | SOORJBALLY HARILALL | special |
| 04/17/2024 | Fire-Resistant Penetrations and Joints | SOORJBALLY HARILALL | special |
| 04/17/2024 | Fire-Resistant Penetrations and Joints | SOORJBALLY HARILALL | special |
| 04/17/2024 | Maintenance information | Soorjbally Harilall | energy_progress |
| 04/17/2024 | HVAC-R and service water heating system controls | Soorjbally Harilall | energy_progress |
| 04/17/2024 | HVAC-R and service water piping design and insulation | Soorjbally Harilall | energy_progress |
| 04/17/2024 | HVAC-R and service water heating equipment | Soorjbally Harilall | energy_progress |
| 04/17/2024 | Energy Code Compliance Inspections | Soorjbally Harilall | progress |
| 04/17/2024 | Sprinkler Systems | SOORJBALLY HARILALL | special |
| 04/17/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | SOORJBALLY HARILALL | special |
| 04/17/2024 | Maintenance information | Soorjbally Harilall | energy_progress |