← Back
Two family frame
131 SUFFOLK AVENUE
💬 Discuss this project
1965Year Built
2Stories
B2Building Class
R3XZoning
2,632 sfGross Floor Area
2Units
5 Open Violations 3 unresolved · 2 paperwork only ▸FDNY Report ↗
Two family frame · 4,590 sf lot · 0.57 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOHAMMAD AHEAD, PE303/19/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EZFILINGNYCORP203/21/2026
Building Lifecycle
All (30)Filed (3)Violation (8)Objection (15)Special Inspection (4)
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/04/2026
Special inspection requirement — Final
04/17/2026
Objection raised — Scope
03/19/2026
Filed — Alteration
HEREWITH FILING AN ALTERATION TYPE 2 APPLICATION FOR AN INTERIOR RENOVATION. FILING TO RELOCATE CONVENIENCE STAIR FROM CELLAR TO FIRST FLOOR, REMOVE EXISTING WINDOW AT FIRST FLOOR AND INSTALL SLIDING DOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01257113-P1
10/03/2025
Objection resolved — Addressed
09/29/2025
Objection resolved — Addressed
09/16/2025
Objection resolved — Addressed
09/05/2025
Objection resolved — Addressed
09/05/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/02/2025
Objection raised — Plumbing
09/02/2025
Objection raised — Cost
09/02/2025
Objection raised — Scope
09/02/2025
Objection raised — Zoning
09/02/2025
Objection raised — Plumbing
09/02/2025
Objection raised — Zoning
09/02/2025
Objection raised — Zoning
08/19/2025
Filed — Alteration
HEREWITH FILING AN ALTERATION TYPE 2 APPLICATION FOR AN INTERIOR RENOVATION. FILING TO RELOCATE CONVENIENCE STAIR FROM CELLAR TO FIRST FLOOR, REMOVE EXISTING WINDOW AT FIRST FLOOR AND INSTALL SLIDING DOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01257113-S1
08/19/2025
Filed — Alteration
HEREWITH FILING AN ALTERATION TYPE 2 APPLICATION FOR AN INTERIOR RENOVATION. FILING TO RELOCATE CONVENIENCE STAIR FROM CELLAR TO FIRST FLOOR, REMOVE EXISTING WINDOW AT FIRST FLOOR AND INSTALL SLIDING DOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01257113-I1
07/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/08/2025
Violation issued (ECB, open)
Construction
07/08/2025
Violation issued (ECB, open)
Construction
06/06/2025
Violation issued (ECB, closed)
Unknown
06/06/2025
Violation issued (ECB, open)
Construction
06/06/2025
Violation issued (ECB, open)
Construction
06/06/2025
Violation issued (ECB, closed)
Construction
06/06/2025
Violation issued (ECB, closed)
Construction
04/23/2025
Violation issued (ECB, open)
Construction
Nothing on file for this building.
1 project · most recent 03/19/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/19/2026——Gas, Water/Sanitary
1 project · most recent 09/16/2025
General Wiring
FiledStatusContractorScope
09/16/2025Permit IssuedACCURATE ELEC'L CORP.General Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
06/04/2026Fire-Resistant Penetrations and Joints—special
06/04/2026Structural Stability – Alterations of existing buildings—special
06/04/2026Final—progress
07/21/2025Fire-Resistant Penetrations and Joints—special
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/18/2026S01257113-P1Request digital key ↗
08/18/2026S01257113-S1Request digital key ↗
08/18/2026S01257113-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/18/2026S01257113-P1Open ↗
08/13/2026S01257113-I1Open ↗
08/13/2026S01257113-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/18/2026S01257113-P1Open ↗
08/13/2026S01257113-S1Open ↗
08/13/2026S01257113-I1Open ↗