| Owner | Filings | Most Recent |
|---|---|---|
| SD DESIGN STUDIO | 7 | 07/08/2026 |
| WING JAY CONSTRUCTION | 2 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| HPL ENGINEERING P.C. | 11 | 06/05/2026 |
| LU ENGINEERING SERVICE PC | 4 | 06/05/2026 |
| HRM ENGINEERING SERVICES, PC | 4 | 11/19/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| H Z BUILDING NY | 28 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| WING JAY CONSTRUCTION INC | General Contractor | 15 | 07/08/2026 |
| JRL SKYLINE INC | General Contractor | 13 | 07/29/2026 |
| SAFEPIPE PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HPL ENGINEERING PC | 5613 | 16 | 06/05/2026 |
| YANG ENGINEERING LLC | 8376 | 1 | 11/12/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | JRL SKYLINE INC | 07/28/2026 |
| DOB NOW | Structural | Permit Issued | JRL SKYLINE INC | 04/28/2026 |
| DOB NOW | Earth Work | Permit Issued | JRL SKYLINE INC | 04/28/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | JRL SKYLINE INC | 04/22/2026 |
| DOB NOW | Support of Excavation | Permit Issued | JRL SKYLINE INC | 04/22/2026 |
| DOB NOW | Construction Fence | Permit Issued | JRL SKYLINE INC | 04/22/2026 |
| DOB NOW | General Construction | Permit Issued | JRL SKYLINE | 08/13/2025 |
| DOB NOW | Structural | Permit Issued | JRL SKYLINE | 04/30/2025 |
| DOB NOW | Earth Work | Permit Issued | JRL SKYLINE | 04/30/2025 |
| DOB NOW | General Construction | Permit Issued | JRL SKYLINE | 04/29/2025 |
| DOB NOW | Construction Fence | Permit Issued | JRL SKYLINE | 04/29/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | JRL SKYLINE | 04/29/2025 |
| DOB NOW | Support of Excavation | Permit Issued | JRL SKYLINE | 04/29/2025 |
| DOB NOW | Structural | Permit Issued | WING JAY CONSTRUCTION INC | 04/24/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | WING JAY CONSTRUCTION INC | 12/09/2024 |
| DOB NOW | Construction Fence | Permit Issued | WING JAY CONSTRUCTION INC | 12/09/2024 |
| DOB NOW | Plumbing | Permit Issued | BELLEROSE PLBG & HTG | 12/05/2024 |
| DOB NOW | Earth Work | Permit Issued | WING JAY CONSTRUCTION INC | 12/04/2024 |
| DOB NOW | Structural | Permit Issued | WING JAY CONSTRUCTION INC | 12/03/2024 |
| DOB NOW | Support of Excavation | Permit Issued | WING JAY CONSTRUCTION INC | 11/20/2024 |
| DOB NOW | General Construction | Permit Issued | WING JAY CONSTRUCTION INC | 11/19/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/05/2026 | Permit Issued | JRL SKYLINE INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PURY-P120TLMU-A 120 BTU · Vrf Outdoor ×3 PURY-P96TLMU-A 96,000 BTU · Vrf Outdoor ×3 PUMY-HP36NKMU 36,000 BTU · Vrf Outdoor ×2 PURY-P192TSLMU-A 192,000 BTU · Vrf Outdoor ×2 PURY-P240TSLMU-A 20 BTU · Vrf Outdoor ×2 PUZ-A24NHA7 24,000 BTU · Heat Pump Outdoor ×2 PURY-P288TSLMU-A 288,000 BTU · Vrf Outdoor ×1 Ventilation Greenheck SP-A50-90-VG 75 CFM · Exhaust Fan ×15 QEID-22-95 11,000 CFM · Exhaust Fan ×4 QEID-15-100 2,800 CFM · Makeup Air ×1 SQ-97-VG 100 CFM · Exhaust Fan ×1 SQ-98-VG 300 CFM · Exhaust Fan ×1 USF-16-B6 4,200 CFM · Exhaust Fan ×1 USF-16-B7 3,500 CFM · Exhaust Fan ×1 USF-18-B6 5,000 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/05/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/22/2025 | Permit Issued | RIGHTWAY ELECTRICAL INC | 1 meters, 1 new_meters |
| 12/05/2024 | Permit Issued | RIGHTWAY ELECTRICAL INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/05/2026 | Permit Issued | JRL SKYLINE INC | 7 scope_items |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/09/2024 | Permit Issued | JRL SKYLINE INC | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/05/2026 | Permit Issued | JRL SKYLINE INC | Earthwork |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/23/2026 | Protection of exposed foundation insulation | Fran Huang | energy_progress |
| 07/23/2026 | Interior lighting power | Fran Huang | energy_progress |
| 07/23/2026 | Metering | Fran Huang | energy_progress |
| 07/23/2026 | Fenestration areas | Fran Huang | energy_progress |
| 07/23/2026 | Lighting in dwelling units | Fran Huang | energy_progress |
| 07/23/2026 | Exterior lighting power | Fran Huang | energy_progress |
| 07/23/2026 | Excavations - Sheeting, Shoring, and Bracing | Fran Huang | special |
| 07/23/2026 | Concrete - Cast-In-Place | Fran Huang | special |
| 07/23/2026 | Underpinning | Fran Huang | special |
| 07/23/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Fran Huang | special |
| 07/23/2026 | Subgrade Inspections | Fran Huang | special |
| 07/23/2026 | Exterior Insulation and Finish Systems (EIFS) | Fran Huang | special |
| 07/23/2026 | Fire-Resistant Penetrations and Joints | Fran Huang | special |
| 07/23/2026 | Construction Operations Influencing Adjacent Structures | Fran Huang | special |
| 07/23/2026 | Luminous Exit Path Markings | Fran Huang | special |
| 07/23/2026 | Masonry | Fran Huang | special |
| 07/23/2026 | Wall Panels, Curtain Walls, and Veneers | Fran Huang | special |
| 07/23/2026 | Chimneys and vents | Fran Huang | special |
| 07/23/2026 | Lighting controls | Fran Huang | energy_progress |
| 07/23/2026 | Fenestration and door U-factor and product ratings | Fran Huang | energy_progress |
| 07/23/2026 | Insulation placement and R values | Fran Huang | energy_progress |
| 07/23/2026 | Air barrier — testing | Fran Huang | energy_progress |
| 07/23/2026 | Electrical motors and elevators | Fran Huang | energy_progress |
| 07/23/2026 | Maintenance information | Fran Huang | energy_progress |
| 07/23/2026 | Vestibules | Fran Huang | energy_progress |